Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid Value. | |
| 2 | L2₹34.1 L+₹1.8 L (5.64%)Rejected-AOC | L2 | Rejected-AOC Higher Bid Value. |
Tender Value
₹38 L
EMD Value
₹72,000
Closing Date
15 Aug 2020, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE HQ TC AIR FORCE BANGALORE 560006
CERTAIN REPAIR/MAINT OF CI/GI/HDPE WATER PIPELINE WITH FITTINGS AND CONNECTED WORKS AT POCKET I /II AND CLEANING OF OH RESERVOIR, SERVICE WATER TANK ,UG SUMPS AND CONNECTED WORKS AT CHAF BANGALORE
2020_MES_358048_2
8696/GE-38
Open Tender
Miscellaneous Services
Item Rate
270 days
CH (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹72,000
Yes
31 Aug 2020
25 Jul 2020
17 Aug 2020
25 Jul 2020
15 Aug 2020
3 Aug 2020
27 Jul 2020 - 30 Jul 2020
Amount
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and getting out in hard/ dense soil for pipe trenches all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm thick with approved soil obtained from excavation all as specified and as directed.
Removing excavated soil not exceeding 50 metre and depositing at a level not exceeding 1.5 metre above the starting point all as specified and as directed.
M&L for repairs/rectification of leakage in UG cast iron /Galvanised iron pipe/DI pipe by means of choking lead wool/ pig lead or tightning of GI fittings/ DI fittings complete including excavation and earth work for exposing the joints and working space on the site, returning,filling in and making good to the existing earth level of the surroundings after repair for the following sizes of pipes all as specified. Note;- (i) Rectification of leakage shall be attended and rectified by the contractor on the same day of reporting by the Engr-in-charge. Non rectification of leakage of pipe line shall be viewed as serious lapse on contractor's part and penal charges as Rs 100/- per complaint (ii) Supply only Lead wool/pig lead shall be measured and paid seperately. (iii) In case excavation beyound 1 mtr from both side of the joint and spares required the same shall be measured and paid separately under respective item.
(a) 100 mm bore
(b) 80 mm bore
(c) 50/40 mm bore
(d) 25/20 mm bore
Taking up or down GI tubing/PPR including all fittings from trenches , wall, floor etc including cleaning by roding for refixing or removing to store for safe custody/ reuse or disposal under schedule of credit and all as specified for the following sizes:-Note : Excavation and earth work where required shall be measured and paid separately under relevant items of this Schedule.
(a) 100 mm bore
(b) 80 mm bore
(c ) 50 mm bore
(d ) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
(g) 15mm bore.
Laying or fixing only of steel tubing/PPR obtained from item Sl No 5 here-in-before including provision of heavy duty ISI marked new GI fittings (Such as socket/ elbow/ Tee/ union/ reducer/ nipple/ flange etc) to wall/flooring /ceiling etc or laid in trenches all as specified. Note : Screwing if required shall be measured and paid separately under respective item
(a) 100 mm bore
(b) 80 mm bore
(c ) 50 mm bore
(d ) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
(g) 15mm bore.
M&L for Cutting of existing GI pipe in position for taking down addition alteration or for repair complete all as specified and directed for the following sizes
(a) 100 mm bore
(b) 80 mm bore
(c ) 50 mm bore
(d) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
M&L for Screwing ( Threads making ) of existing galvanised steel tubing for addition alteration extending or reducing in length for repair all as specified and directed for following sizes.
(a) 100 mm bore
(b) 80 mm bore
(c) 50 mm bore
(d ) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
M & L for water tubing or GI pipe , medium grade, galvanized, in trenchesor fixed on walls/ floors/ roofs etc with and including provision of all connected fittings complete all as specified and as directed.Note : Excavation and earth work where required shall be measured and paid separately under relevant items of this Schedule.
(a) 100 mm bore
(b) 80 mm bore
(c) 50 mm bore
(d ) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
(g) 15 mm bore
S & F Polypropylene Random Copolymer 3(Three) layer (PP-R) Pipes SDR 7.4 & SDR 11 UV stablized green coloured, inner anti microbial, fusion welded, having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fitting, laid in trenches for the following sizes of pipes complete all as specified and directed.
(a) 110mm OD
(b) 90mm OD
(c) 63mm OD
(d) 50mm OD
(e) 32mm OD
(f) 25mm OD
Supply and fix in replacement gun metal gate valves with iron wheel head screwed both ends for GI pipe all as specified for the following sizes:-
(a) 50 mm bore
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
S&F in replacement Gun metal gate or globe valve, heavy duty, ISI marked, with iron wheel head screwed both end for 15mm bore GI tubes, fixed in repairs, all as specified and as directed.
Supply and fix in replacement Ball brass valves, high pressure, with polythene float and fly- nut complete for GI pipe/PPR pipe all as specified for the following sizes:-
(a) 50 mm bore
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
Supply and fix in replacement PP-R Ball brass valves,(brass insert) high pressure, with polythene float and fly- nut complete for GI pipe/PPR pipe all as specified for the following sizes:-
(a) 40 mm bore
(b) 25 mm bore
(c) 20 mm bore
S & F in repair PP-R gate valve (brass insert) as per requirement of site and fixed in position including taking down unserviceable gate valves for the following size complete all as specified and directed.
(a) 63 mm OD.
(b) 50 mm OD.
(c) 32 mm OD.
(d) 25 mm OD
Taking down old U/S Ductile iron pipe and M & L Ductile iron pipes, Class K-7, with spigot and socketed ends centrifugally cast (spun) with factory applied cement mortar lining inside the pipes and outside with zinc coating with suitable push on joint (Rubber gasket D joint) confirming to IS 8329/2000 of size 150 mm bore and connected itemes complete all as specified and directed at site
Taking down old U/S Ductile iron pipe and M & L Ductile iron pipes, Class K-7, with spigot and socketed ends centrifugally cast (spun) with factory applied cement mortar lining inside the pipes and outside with zinc coating with suitable push on joint (Rubber gasket D joint) confirming to IS 8329/2000 of size 100 mm bore and connected itemes complete all as specified and directed at site Note for item No 15 &16 : Excavation and earth work and DI specials where required shall be measured and paid separately under relevant item of this schedule.
Taking down old U/S Ductile iron fittings and M & L Ductile iron fittings, heavy duty, such as bends, tapers, tees, collars, tail pieces, reducers, etc. laid and jointed with suitable push on joints complete all as specified and as directed.
M & L Run lead joints for CI spigot and socket pipes and fittings for the following sizes all as specified and as directed.
(a) 300mm bore
(b) 250mm bore
(c )150mm bore
(d)100mm bore
(e)80mm bore
M & L Cutting cast iron pipes in position for insertion of new fittings or for carrying out repairs of following sizes all as specified and as directed. Note:-Excavation and earth work, CI / DI fittings where required shall be measured and paid separately under relevant item of this schedule.
(a) 150mm pipes
(b)100 mm pipes
Taking down old U/S Cast iron fittings and M & L Cast iron fittings such as bends, tapers, tees, collars, tail pieces, reducers, etc. for spigot / socketed pipes of any size complete all as specified and as directed.
S & F inreplacement Sluice valve cast iron body with brass spindle, class-1 ISI marked, PN-1.5, both end flanged and drilled and fixed with bolts and nuts and washers including providing rubber insertion of suitable thickness complete of following sizes including taking out existing unserviceable sluice valves all as specified and as directed
(a)150mm bore
(b)100mm bore
(c)80mm bore
M & L Graphite gland packing, suitable for sluice valves or pump sets, fixed in position including taking down unserviceable gland packing as per site requirement.
Material and labour for construction of brick masonry valve pit of size 60 cm x 60 cm x 60 cm (internal dimensions) with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation, 15 mm thick rendering in cement mortar (1:4) internally and externally up to 15 cm below ground level including, provision of valve pit cover made out of 3 mm thick MS sheet welded with 40 x 5 mm thick flat iron all round, on ISA 40 x 40 x 6 mm frame, fixed with hold fast 150 mm long, embedded in PCC (1:2:4) type B1 (Block size 230 x 200 x 100 mm) with necessary hinges, handles, locking arrangement, including applying two coats of white wash on plastered surfaces and two coats of bituminious paint over a coat of red oxide primer on steel surfaces and ncessary earth work in soft/loose soil complete all as specified and directed.
All as per item No 25.0 here in but of size 90cm x 90cm x 90cm
All as per item No 25.0 here in but of size 750cm x 750cm x 750cm
All as per item No 25.0 here in but of size 900cm x 900cm x 900cm
M&L inreplacement valve chamber cover with frame and locking arrangement made out of angle iron or other section and MS sheet 3mm thickness with welding of holdfast etc. including hinges fabricated MS is not less than the thickness of frame all as specified including preparation of surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces etc complete all as specified and directed.
Supply and Laying High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm 2 laid in trenches/Walls complete connected items all as specified and directed
(a) 40mm bore
(b) 50 mm bore
Taking down old U/S items and M & L for Mechanical joint complete all as specified and directed
(a) 150mm bore
(b) 100mm bore
M&L for synthetic enamel paint and one coat of Red oxide primer on old painted steel servicess including preparation complete all as specified and directed at site.
M&L for brick masonry with sub class B bricks, straight or curved on plan exc 6m mean radius in cement mortar 1:6 all as specified.
M&L for rendering with 10 mm thick in cement mortar 1:4 on fair surfaces of brick work or concrete surfaces finished even and smooth surfaces without using extra cement and all as specified.
Supply , fixing and connecting inreplacement MCCB 4 Pole ,415 Volt magnetic release( thermal setting 70 to 100 % ond magnetic setting 6-10 in) Adjustable Type 100 Amp with breaking capacity 25 KA.complete with extension links and connection in panel board all as specified and as directed. Make- Havells/L&T/HPL etc
S&F in repair Single phase preventer ES-00 type for 3 phase motor upto 30 HP cap -01 No Make all as specified and as directed. L&T/Schneider/Siemens
S&F in replacement Digital ammeter with necessary CTs range 0-100 Amps square type all as specified and directed
S&F in replacement Digital volmeter range 0-500 volts square type all as specified and directed
Supply and fix in replacement three phase VAFPF (Voltage, Amp, Frequency and Power factor meter) in pump house electric panels with accuracy class 0.5 operating voltage 420 Volts conforming to cat part no EM 6459 1.0 of Schneider or equivalent all as specified and as directed.
Material and labour two coat of cement base paint (snowchem) on external walls to semiunder ground tanks complete including preparation of surface Washing, rubbing down and stopping of distempered and painted surfacesh complete all as specified and directed.
Suply and fix in repair brass spindle for sluice valve 150mm with GM check nut (as per sample) suitable all as specified and directed
All as per item No 38.0 here in before but suitable for sluice valve 100 mm dia (as per sample) suitable all as specified and directed
All as per item No 38.0 here in before but suitable for sluice valve 80 mm dia (as per sample) suitable all as specified and directed
Supply and fix in repair gun metal check nut (as per sample) with inner threads suitable for 100 mm Sluice valve all as specified and directed
Supply and fix in repair gun metal check nut (as per sample) with inner threads suitable for 80 mm Sluice valve all as specified and directed
M&L for construction for MS float box made out of MS Sheet of 1.6mm thick and of size 30 x 30 x 25cm complete painting black bituminous paint incl supply and fixing of nylon rope of suitable size and making for water level indicator plate of over head tank, at the height of 40 feet testing complete all as directed.
M&L for Structural steel work with Fe-290 (Gde E-165) with compound girder and stanchoins , lattice girders, aerial mast staging of water tank and like inluding caps bases splices etc built up from two or more beam or channel section or angle with plates, including all lattice bars, stiffeners , gusset plate etc and replacement of necessary MS angles of size of suitable length with necessary fittings and fixtures bolts nuts washers etc including required welding work complete all as specified.
M&L for synthetic enamel paint and one coat of Red oxide primer on old painted steel servicess including preparation complete all as specified and directed at site.
Note Item no 1 to 45 : If any major break down of water supply at site with in 24 hrs of receipt of intimation from Engineer-in-charge and contractor shall ensure that the fault is rectified with in 48 hrs of receipt of intimation from engineer-in-charge any failing which recovery of Rs 300 per hour shall be recovered from the contractor dues w.e.f the time immediatley after the expiry of 48 hours duration.
M&L De-watering, removing all mosses, algae and dirt from internal walls, floors & mouths of pipes of RCC overhead reservoir/ under ground sump by using steel wire brush and cleaning with high pressure industrial vacuum cleaner including removing of dirty water completely using sludge pump set and disposing off the same to a safe distance and applying of anti bacterial sterilization spray to internal surfaces using Zero bacterial compound (Sodium hypochlorte) or equivalent approved chemical complete and writing the date of cleaning on outside of tank/ sump using synthetic enamel paint of white colour over black background with letters of size 100mm height x 100mm breadth complete all as specified and directed for the OH Reservoir of 75000 Gallons capacity with 24 metre staging all as specified and directed.
All as per SI item No 47.0 above but for Overhead reservoir 50,000 Gallons capacity with staging exceeding 15 metres and not exceeding 24 metres
All as per SI item No 47.0 above but for Overhead reservoir 15,000 Gallons capacity with 6 metres staging
All as per SI item No 47.0 above but for Overhead reservoir 5000 Gallons capacity with staging of 6 metres
All as per SI item No 47.0 above but for UG sump 2,00,000 Gallons capacity
All as per SI item No 47.0 above but for UG sump 1,50,000 Gallons capacity
All as per SI item No 47.0 above but for UG sump 1,25,000 Gallons capacity
All as per SI item No 47.0 above but for UG sump 20,000 Gallons capacity
All as per SI item No 47.0 above but for UG sump 10,000 Gallons capacity
M&L De-watering, removing all mosses, algae and dirt from internal walls, floors & mouths of pipes of RCC overhead tanks (Service tanks) by using steel wire brush and cleaning with high pressure industrial vacuum cleaner including removing of dirty water completely using sludge pump set and disposing off the same to a safe distance and applying of anti bacterial sterilization spray to internal surfaces using Zero bacterial compound (Sodium hypochlorte) or equivalent approved chemical complete and writing the date of cleaning on outside of tank using synthetic enamel paint of white colour over black background with letters of size 50mm height x 50mm breadth, complete all as specified and directed for OH service tank upto 500 litres capacity.
All as per SI item No 56.0 above but for OH service tank exceeding 500 litres and not exceeding 1000 ltrs capacity.
All as per SI item No 56.0 above but for OH service tank exceeding 1000 litres and not exceeding 2000 ltrs capacity
All as per SI item No 56.0 above but for OH service tank exceeding 2000 litres and not exceeding 5000 ltrs capacity
M&L De-watering, removing all mosses, algae and dirt from internal walls, floors & mouths of pipes of PVC overhead tanks (Service tanks) and cleaning with high pressure industrial vacuum cleaner including removing of dirty water completely using sludge pump set and disposing off the same to a safe distance and applying of anti bacterial sterilization spray to internal surfaces using Zero bacterial compound (Sodium hypochlorte) or equivalent approved chemical complete and writing the date of cleaning on outside of tank using synthetic enamel paint of white colour over black background with letters of size 50mm height x 50mm breadth, complete all as specified and directed for OH service tank upto 500 litres capacity
All as per SI item No 60.0 above but for OH service tank exceeding 500 litres and not exceeding 1000 ltrs capacity
All as per SI item No 60.0 above but for OH service tank exceeding 1000 litres and not exceeding 2000 ltrs capacity
All as per SI item No 60.0 above but for OH service tank exceeding 2000 litres but not exceeding 5000ltr capacity. Note for Sl item No 47.0 to 63.0:- (i) Any damage caused to tank, lid, ball valve, pipe line and connected items during cleaning shall be repaired or replaced by the contractor without any extra cost. (ii) any damage caused to fresh water line / inlet tank pipe line over the building and connected item shall be repaired or replaced accordingly. (iii) After tank cleaning register to be mantain for obtaining signature from users and submitted to Engr-in-charge before processing RAR. (iv) Cleaning of tank shall be carried out as per site requirement complete all as specified and directed.
S&F in replacement PTMT ball valve, high pressure, with epoxy coated aluminium rod and high density plastic ball screwed for 15mm bore GI tubes, fixed in repairs, all as specified and as directed.
All as per item No. 64.0 above but for 20mm bore GI tubes
All as per item No. 64.0 above but for 25mm bore GI tubes
All as per item No. 64.0 above but for 40mm bore GI tubes
All as per item No. 64.0 above but for 50mm bore GI tubes
S&F in replacement PVC lid suitable for PVC tanks of capacity 500/1000/2000 litres, fixed in repairs all as specified and as directed.
Dismantling water tanks of capacity exc 250 ltr and n.exc 500 ltr and removing to store.
Dismantling water tanks of capacity exc 500 ltr and n.exc 1000 ltr and removing to store.
S&F rotational moulded PVC water storage tank 500ltrs capacity conforming to IS-12701(1989) cylindrical vertical type double-layered with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc complete all as specified and as directed.
S&F rotational moulded PVC water storage tank 1000ltrs capacity conforming to IS-12701(1989) cylindrical vertical type double-layered with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc complete all as specified and as directed.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling/floors complete all as specified and as directed. Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching upto roof top.
Supplying and laying of 25m outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling/floors complete all as specified and as directed. Note :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching upto roof top.
S& F in replacement of GI ELBOW threaded, 20 mm bore fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
S& F in replacement of GI TEE threaded, 20mm bore fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
S& F in replacement of GI SOCKET threaded, 20mm bore fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
S& F in replacement of GI UNION threaded, 20mm bore fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
S& F in replacement of GI PLUG threaded, 20mm bore fixed to walls and ceiling laid in floors including testing complete all as specified and directed.
S& F in replacement of GI NIPPLE threaded, 20mm bore fixed walls and ceiling to laid in floors including testing complete all as specified and directed.
S& F in replacement of GI REDUCER threaded, 025x20mm bore,ISI marked fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
B5BUILDING SOLUTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .