Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | ₹41.0 L | L1 | Accepted-AOC Contract Awarded being lowest bidder. |
| 2 | L2₹42.8 LRejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹42.8 L | L2 | Rejected-AOC Rejected due to Higher Amount Quoted. |
| 3 | L3₹46.4 LRejected-AOC 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | ₹46.4 L | L3 | Rejected-AOC Rejected due to Higher Amount Quoted. |
| 4 | Rejected-Technical 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | - | - | Rejected-Technical Not admitted due to firm is not having appropriate category i.e. b (ii) as mentioned in NIT. |
| Sl No | Description | Qty | Unit | Electricals India L1 | MONA GENERATOR SEVICES PVT. LTD. L3 | ARTI CONSTRUCTION L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and Install of Copper wound Transformer step down, outdoor type complete with standard fitttings, HT 11KV 3 Phase, LT 433 Volts, 3 Phase 4 wire of capacity 250 KVA, 11/0.433 kV, (copper Wound), "ENERGY EFFICIIENT" , LEVEL- 3 ", Oil immersed , Outdoor, Delta-star Transformer with Off-load Tap Changer on HT side to vary secondary voltage within limit, as per BIS 1180-2014(Part-I) and IS-2026 Specifications.
(a) Capacities - 250 KVA , LEVEL 3, ENERGY EFFICIENT, with losses at 50% & 100% are 864W & 2488W respectively
(b) Type - Oil Immersed / Copper Wound.
(c) Number of Phases - Three.
(d) NO Load Voltage Ratio - 11000/433 Volts.
(e) Frequency - 50Hz.
(f) Duty - Outdoor.
(g) Vector Group - Dyn-11, Delta/Star.
(h) Type of Tap switch changer - 6-step, 7-Positions, Off-load Tap Changer.
(j) Taping Range - +5% to -10% of HV in 6-Steps @2.5% Each.
(k) Temperature Rise Oil/Winding - 40 to 45 degree celcius
(l) Type of Cooling - ON AN
Standard Fittings:-
1. Metal Parts for HT and LT fittings with HT Bushings on Top Cover and LT Cable Box.
2.Conservator fitted with CI Oil Gauge, Oil Filling Hole and CI Cap & Drain Valve.
3. 6-Step, 7-Positions, Off-Load Tap Changer.
4. Dial Thermometer for oil temperature.
5.Dehydrating silica gel Breather, Arcing Horns and Earthing Terminals. | 1 | Each | 9,99,005 ₹9,99,005 | 11,96,432 ₹11,96,432 | 10,80,000 ₹10,80,000 |
| 2.00 | Material and Labour for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed, | 4 | Each | 10,000 ₹40,000 | 32,750 ₹1,31,000 | 9,850 ₹39,400 |
| 3.00 | Material and Labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. | 2 | Each | 10,801 ₹21,602 | 42,865 ₹85,730 | 11,126 ₹22,252 |
| 4.00 | Supply, laying, testing & commissioning in replacement of XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, PVC inner sheath, galvanized steel strip armoured and overall PVC sheathed electric power cables(heavy duty) with stranded aluminum conductor of cross sectional area 95 sqmm, 3 core, 11000 volts grade(Earthed) cable confirming to IS 7098 complete all as specified and directed. | 300 | RM | 1,134 ₹3,40,200 | 987 ₹2,96,100 | 1,141 ₹3,42,300 |
| 5.00 | Material and Labour in replacement of air break switch vertical rotating type gang operated (GOD) triple pole mechanically operated, mounted on insulators (09 insulators) & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 200 amps and all as specified and directed. | 1 | Each | 21,600 ₹21,600 | 18,157 ₹18,157 | 21,708 ₹21,708 |
| 6.00 | Supply and fix HT 11 KV outdoor metal type 12 KV (rms) lightening arrestor polymeric housing with mountings,accessories complete fixed on cross arms of two pole structure /GI flat strip and connect with same size of ACSR conductor encased in PVC alkathine pipe with all fittings connected to earth stripwith nut,bolt ,washer transmission class having discharge capacity of 65 kilo Amps complete all as specified and directed.
Note: MS channel/ cross arms,nut bolt and washer shall be maeasured and paid separately under respective schedule of item. | 1 | Set of Three | 19,980 ₹19,980 | 11,260 ₹11,260 | 19,381 ₹19,381 |
| 6.01Supply and fix drop out fuse unit explusion type for out door double stack channel air break pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nut,bolts and washer ect. Suitable for current carry capacity upto 200 Amps complete all as specified and directed. Note: MS channel ,nut, bolt and washer shall be measured and paid separately under respective schedule of item. | ||||||
| 7.00 | Material and Labour in replacement steel work such as in cross arms angle iron breaching supports, clamps and back plate fabricated from MS section confirming to grade Fe-410 -0 or Fe -310 -0 including nuts, bolts, washers, bending cold or hot drilling holes bolts in any shape or size as indicated or directed included of one primer coat, one under coat & one finishing coat of aluminium paint and all as specified and directed. | 3 | Per Quintal | 12,600 ₹37,800 | 10,186 ₹30,558 | 12,852 ₹38,556 |
| 8.00 | M & L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-55, 11 mtr long including , anti-climbing device, HT Danger notice plate, HT Insulators, ACSR conductor as required at site etc including painting to pole two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete all as specified and directed.Charge.
Note :- (i) Cross arms, PCC for foundation and coping work shall be measured and paid for separately.
(ii) Pole has required for errecting two pole structure. | 2 | Each | 25,920 ₹51,840 | 24,933 ₹49,866 | 26,439 ₹52,878 |
| 9.00 | Material and labour for plain cement concrete (1:4:8) D2 type using 40 mm graded course aggregate for foundation etc. | 1.62 | Cum | 3,600 ₹5,832 | 5,403 ₹8,752.86 | 3,672 ₹5,948.64 |
Tender Value
Refer Docs
EMD Value
₹87,200
Closing Date
1 Jan 2026, 6:00 pmClosed
CWE AHMEDABAD
CWE Ahmedabad Hanuman Camp Shahi Baug Ahmedabad
PROVISION OF TRANSFORMER AND ALLIED EXTERNAL ELECTRIC SERVICES FOR GKOI, NCC DTE AND 944 TPT COY AREA AT MILITARY STATION AHMEDABAD
2025_MES_742126_1
87472/E8
Open Tender
Electrical and Maintenance Works
120 days
ARMY AREA AHMEDABAD
AS PER TENDER DOCUMENT
6 documents required · 6 mandatory
₹500
GE (A) AHMEDABAD
₹87,200
6 Feb 2026
29 Nov 2025
8 Jan 2026
29 Nov 2025
1 Jan 2026
15 Dec 2025
29 Nov 2025 - 13 Dec 2025
Supply and Install of Copper wound Transformer step down, outdoor type complete with standard fitttings, HT 11KV 3 Phase, LT 433 Volts, 3 Phase 4 wire of capacity 250 KVA, 11/0.433 kV, (copper Wound), "ENERGY EFFICIIENT" , LEVEL- 3 ", Oil immersed , Outdoor, Delta-star Transformer with Off-load Tap Changer on HT side to vary secondary voltage within limit, as per BIS 1180-2014(Part-I) and IS-2026 Specifications. (a) Capacities - 250 KVA , LEVEL 3, ENERGY EFFICIENT, with losses at 50% & 100% are 864W & 2488W respectively (b) Type - Oil Immersed / Copper Wound. (c) Number of Phases - Three. (d) NO Load Voltage Ratio - 11000/433 Volts. (e) Frequency - 50Hz. (f) Duty - Outdoor. (g) Vector Group - Dyn-11, Delta/Star. (h) Type of Tap switch changer - 6-step, 7-Positions, Off-load Tap Changer. (j) Taping Range - +5% to -10% of HV in 6-Steps @2.5% Each. (k) Temperature Rise Oil/Winding - 40 to 45 degree celcius (l) Type of Cooling - ON AN Standard Fittings:- 1. Metal Parts for HT and LT fittings with HT Bushings on Top Cover and LT Cable Box. 2.Conservator fitted with CI Oil Gauge, Oil Filling Hole and CI Cap & Drain Valve. 3. 6-Step, 7-Positions, Off-Load Tap Changer. 4. Dial Thermometer for oil temperature. 5.Dehydrating silica gel Breather, Arcing Horns and Earthing Terminals.
Material and Labour for Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed,
Material and Labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Supply, laying, testing & commissioning in replacement of XLPE insulated, insulation screening with extruded semi conducting compound in combination with copper tape, cores laid up, PVC inner sheath, galvanized steel strip armoured and overall PVC sheathed electric power cables(heavy duty) with stranded aluminum conductor of cross sectional area 95 sqmm, 3 core, 11000 volts grade(Earthed) cable confirming to IS 7098 complete all as specified and directed.
Per Quintal
Material and Labour in replacement steel work such as in cross arms angle iron breaching supports, clamps and back plate fabricated from MS section confirming to grade Fe-410 -0 or Fe -310 -0 including nuts, bolts, washers, bending cold or hot drilling holes bolts in any shape or size as indicated or directed included of one primer coat, one under coat & one finishing coat of aluminium paint and all as specified and directed.
Material and Labour in replacement of air break switch horizontal rotating type gang operated (GOD) triple pole mechanically operated, mounted on insulators (09 insulators) & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11 KV grade working pressures and current upto 200 amps and all as specified and directed.
M & L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts & screws as specified type 410 SP-55, 11 mtr long including , anti-climbing device, HT Danger notice plate, HT Insulators, ACSR conductor as required at site etc including painting to pole two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete all as specified and directed.Charge. Note :- (i) Cross arms, PCC for foundation and coping work shall be measured and paid for separately. (ii) Pole has required for errecting two pole structure.
Material and labour for plain cement concrete (1:4:8) D2 type using 40 mm graded course aggregate for foundation etc.
Material and labour for plain cement concrete (1:2:4) B1 type using 20 mm graded course aggregate for coping etc.
Material & labour for Earthing using galvanised iron earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers made of GI and protected by light grade 40 mm dia galvanised iron pipe and GI pipe light grade 20mm bore for watering, including funnel, wire mesh, FRP pit chamber with cover (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 3 of SSR Part-I 2009. for:(a) Transformer - 04 Nos (b) 2 Pole Structure - 04 Nos (c) APFC Panel - 02 Nos (d) LT Panel - 02 Nos (e) VCB - 2 Nos
Excavation in trenches in any type of soft/ loose soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Supply and laying of DWC (double wall corrugated) HDPE pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 50 mm and inner dia 38 mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specified and directed by Engr-in-charge.
All as per Item no-15 above but of size outer dia 77 mm and inner dia 63 mm
All as per Item no-15 above but of size outer dia 120 mm and inner dia 103 mm
Supply and Fix old rusted galvanized iron pipe including supply & Fix galvanized pipe 100 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed.
Supply, laying & testing cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of following sizes :-
400 sqmm 3.5 core
95 sqmm 3.5 core
70 sqmm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
25 sqmm 3.5 core
Supplying, installation, Connecting electrically & commissioning and testing of Outdoor type free standing type (IP -65) automatic power factor correction system with both auto and manual options type Inlet Var APFC Panel with MD - XL capacitors and MCCB as incomer factory made Non compartmentalised single unit 440 Volts 50 Hz , 3 phase 125 KVAR (Multiple of 5 KVAR) Complete all as specified and as directed including the following : (a) Double Metallized paper with polypropylene film cylinderical, type MD-XL capacitor bank of rated voltage 525 volts with detuned Reactor of de - tuning factor (P) 7% and suitable output of 120 KVAr at 440 Volts confirming to IS -13340, 13341, & IEC - 60831 - 1+2. Make : ABB/Schneider (Mehar) / Areava/ Seimens/L&T/Havells (b) Capacitor duly contactor with Damping Resistors appropriate rating for capacitor switching confirming to IEC - 60070 & IS 13947. Makes : ABB/ AREVA/ Schneider/L&T/Havells (c) Automatic power factor controller relay micro processor based for switching ON & OFF of capacitors and suitable to display of voltage , current, active power, Reactive power, Apparent power, Display of power factor, THD Voltage, THD current, alarm indication for defective steps, low power factor and excess temperature. The relay has volt free c/o contact, Automatic detection and usage of optimum capacitors. (i) Capable of 4 - Quadrant operation, and any phase offset requirement. (ii) Swithching programms : LIFO, Combi - filter, manual mode. (iii) Build in under and over voltage release with auto reset. (iv) Large Voltage input band of 90 Volt to 550 Volt , 45 - 65 Hz. (v) Current measuring 10 mA - 5A , Suitable for CT x/1A and x/5A. (vi) Commissioning without additional settings and programming. (vii) Three decimal power factor reading. Make : Schneider/ Beluk/L&T/Simens/Havells/Areva/ABB
M&L for Transformer platform upto 500 KVA out door type made of brick masonry size 2000mm x 2000mm x 1400mm, over PCC foundation 1:3:6 type C-2, with brick work sub class'B' bricks in cement motar 1:4 and plaster work 10mm thick in cement plaster 1:4 incl sand filling and elevated with Angle iron guard rail of 600mm height welded with M.S Angle iron 60x60x6mm, MS flat 50x6mm for interlocking arrangements and guard rails wire netting of galvanized steel wire 1.40mm dia with 25x25mm mesh size fixed with tinned tracks of wire staples duly painted with two coat of synthetic enamel aluminium/smoke grey paint over a coat primer complete.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
TENDER.pdf
Tender Documents • 0.91 MB
BOQ_831022.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid