Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹1.4 L+₹8,188 (6.41%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹1.4 L+₹12,061 (9.44%)Accepted-Finance | L3 | Accepted-Finance OK |
Tender Value
₹1.9 L
EMD Value
₹3,866
Closing Date
22 Mar 2024, 3:00 pmClosed
Executive Engineer (Elect)
T.E. Building KBN, Room No -25, Kidwai Bhawan MTNL, New Delhi-110001
Refurbishment of Electrical works at various sites under Electrical sub division (KBN),MTNL,ND
2024_MTNL_798652_1
EE(E)KBN/2023-24/16-03-24/162
Open Tender
Miscellaneous Services
Item Rate
15 days
Kidwai Bhawan
Please refer Tender documents.
7 documents required · 7 mandatory
₹590
Yes
MTNL Delhi
₹3,866
Yes
27 Mar 2024
16 Mar 2024
23 Mar 2024
16 Mar 2024
22 Mar 2024
16 Mar 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/PVC trunking as required. a)3 x 1.5 sqmm
b) 3 X 4 sqmm
Supplying and fixing of following sizes of steel/PVC conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.a)25 mm steel
b)20 mm steel
c) 20 mm (PVC)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. a) 2 Module (75mmX75mm)
b)3 Module (100mmX75mm)
c)4 Module (125mmX75mm)
e) 8 Module (125mmX125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. a) 4 Module
b) 8 Module
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(Make Anchor Roma) a)5/6 amps switch
b)15/16 amp switch
c)3 pin 5/6 amp socket outlet
d)6 pin 15/16 amp socket outlet
e) Stepped type electronic fan regulator
f) modular blanking plate
g) Bell Push
(h) Hylam sheet
Supplying and fixing following rating MCB/Isolator in the existing SDBs connections complete as reqd.-M/s Havells/Legrand/L&T/ABB/C&S a)63 Amp DP Isolator
b)5/15/32 A SP MCB " C" curve
S/F 4 feet LED Batten fitting with integral electronic driver and LED tube operated on 230 V 50 Hz AC Supply on surface with mounting arrangement connections etc complete as reqd (System wattage 20-22 W system, lumen output-1850-2000 lumens etc) Make-Philips,Osram, Havells
Providing and fixing call bell on wall/surface etc as reqd
P/F wall mounted decorative light with lamp holder and bulb (7W/9W) etc as reqd. Make-Philips,Osram, Havells, Bajaj
S/F 1200 mm sweep AC 230 volts single phase ceiling fan with all accessories including blades capacitor connection testing etc as reqd.(M/S Cromption /USHA/Orient/Bajaj/Luminous/kaithan/Crompton make)
Replacement of existing Gate light with new 25 to 30W LED post-top Gate Light fitting with symmetrical light distribution, spun aluminium landscape luminaire with high power LED as light source & suitable modification work of existing pole according to the size of above fitting etc and dismantling the old faulty fitting etc as reqd (Make: Surya Model No. SLE PT 30W-ETPP or equivalent model of Crompton/ Havells / Bajaj / Philips/Syska/Orient/SS)
Supplying and fixing of the following items including dismantling the old electrical accessories (where ever required), making suitable necessary modification/arrangement (i/c petty items) for fixing the new items and making connections etc complete as reqd as per the site location given by the Engineer-in-Charge. a) 300 mm ventillation fan metallic range. (Make: Orient Electric/ Havells/ Almonard)
Replacement/S/F pole box of size 200mm x 150mm (app.) made out of polycarbonate thermoplastic enclosure shock proof, rust proof, water proof having internally embedded gasket, fixing on existing GI poles with 2 nos. factory fabricated GI clamps (wherever required)/ pole box fixing arrangement, complete with 1 no. 6 amp DP MCB of approved make and interconnections etc. as reqd. (Pole box make: Sintex)
Replacement of existing faulty street light with new 25-30W, IP-66, LED street light luminaires having Aluminium die cast housing and clear toughened glass with synthetic rubber gasket, integral gear on existing pole/ bracket suitable for operation on 230V, 50Hz, single phase AC supply i/c all type of modification in existing pole/bracket complete as reqd. (Make: Surya / Crompton/ Havells / Bajaj / Philips/Syska/Orient)
SITC of 7 to 9 watt energy efficient LED bollard light fitting(minimum up to 500 mm height (apx ) with LED bulb of 9W) i/c grouting nut bolt in existing foundation etc as required. (Make : Philips / Bajaj / Havells/surya/polycab/SS).
P/F CC Foundation of size 600 mm x 300 mm of ratio 1:2:4 i/c providing suitable size of GI pipe( hockey pipe) for incoming and out going cables, excavation & plastering works suitable for bollard light etc complete as reqd
S/L of following sizes PVC insulated and PVC sheathed armoured copper cable and fixing on the wall /existing pipe/laying in under ground etc as reqdMake-M/S poly cab/KEI/Havells/Finolex a) 3 x 1.5 sqmm
Supplying/Laying /Fixing of following size GI Pipe in floor /road i/c cutting of floor /road & repairing the same with CC (1:2:4)etc as per requirement suitable for crossing of required size armoured power cables etc as required. (a) 65 mm dia GI Pipe
Supply, installation, testing and commissioning of following rating single phase self priming motor pump set operation on 240 Volts, 50 HZ AC supply and fixing on the existing foundation complete with inlet and out let connectioni/c all type of inlet out let pipe line modification for connection etc complete as reqd ( Make :- Crompton/ Kirloskar/V guard)a)0.5 HP
Less credit for dismantled material (Dismantling of old faulty fittings, rusted conduits ,existing faulty compound lights, faulty gate light, faulty ceiling fans,faulty wires etc at different area as per the instruction of engineer in charge etc as reqd)
BK Engineers India
Star Electric Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .