| 1 | L1₹7.1 LAccepted-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹7.6 L+₹39,950 (5.54%)Rejected-AOC | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹7.7 L+₹47,310 (6.56%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
23 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
CERTAIN REPAIR AND REPLACEMENT OF DISTRIBUTION PANELS, CABLES SUBMAINS AND EATHING OF VARIOUS BUILDING OF DEAL AND IRDE AREA UNDER GE (I) R N D DEHRADUN.
2021_MES_492354_1
GE(I)RND/9088/E8/21-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DEHRADUN
Class E Category b (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2012) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
GE I R N D DEHRADUN
₹20,000
6 Jan 2022
3 Dec 2021
25 Dec 2021
3 Dec 2021
23 Dec 2021
10 Dec 2021
3 Dec 2021 - 10 Dec 2021
60 days
Amount
S&F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20 amp,240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet. Make of SPN DB with MCB 20Amp - of Indo Asian/Legrand/Schneider/ Havells as approved.
S&F in replacement UNSV of triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 amp, 415 Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp as required. Make of MCB SP 16/20 Amp- of IndoAsian/Legrand/Seimens/Schneider Make of TPN DB with MCB 63Amp - of Indo Asian /Legrand/Schneider / Havells as approved.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.50 Sqmm as earth continuity conductor complete all as specified and directed. Notes for item No.3 & 4: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
M&L in replacement UNSV of sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed.
M&L in replacement UNSV of sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Notes for Item 5 to 6 here in above : (i) Four run of single core PVC cable with two run of earth conductor and one run of conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
S&F in replecement of UNSV vertical type load line distribution board ,double door, 4 way, AC 3 Phase 415 volt with TPN bus bar 250 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefitted masking sheeet,reversible door for IP 43-"IK 09 with metal door with provision for DPX3 160 MCCB as incomer and SP/TP MCB's as out going complete all as specified and directed by Engr-in-Charge. Make of VTPN DB:-Indo Asian cat Part No-811893 or equivalent make in Havells/L& T.
S&F in replacement of UNSV MCB distribution board SPN, 240 volts, 8 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Legrand Cat Pt No. 4025 07 or equivalent in Havells/L&T/Schneider/ IndoAsian as approved
All as per item No 8 above but SPN, 240 volts, 12 ways. Make - Legrand cat ref no 4025 08 or equivalent in Havells/L&T/Schneider/ Havells as approved. Note for Item No.5 to 9.(i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing
Supply and fixed in replacement of UNSV MCCB 4 pole,160 Amps, 415 volts, 50 Hz having breaking capacity 25 KA , with adjustable thermal magnetic protection unit and testing Complete all as specified and directed. Make- IndoAsian cat part No. 830334 or equivalent in seimens / Schinder/ Havells as approved by GE.
All as per item No 10 above but, MCCB 4 pole ,100 Amps, 415 volts, 50 Hz having breaking capacity 16 KA Complete all as specified and directed. Make- IndoAsian cat part No. 830332 or equivalent in seimens / Schinder/ IndoAsian/ Havells as approved by GE .
All as per item No 10 above but MCCB 4 pole,63 Amps, 415 volts, 50 Hz having breaking capacity 10 KA Complete all as specified and directed. Make- IndoAsian cat part No. 830330 or equivalent in seimens / Schinder/ IndoAsian as approved by GE.
S & F in replacement of unserviceable MCB TP 415 volts, short circuit breaking capacity,Icn 10 kA, 'C' Curve suitable for fixing in MCB DB of capacity 40 amps complete all as specified and directed.Make - IndoAsian cat ref no 811218 or equivalent in Hager or Schneider/ Havells as approved.
S & F in replacement of unserviceable MCB FP 415 volts,short circuit breaking capacity,Icn 10 kA, 'C' Curve suitable for fixing in MCB DB of capacity 40 amps complete all as specified and directed.Make - IndoAsian cat ref no 811240 or equivalent in Hager or Schneider / Havells as approved.
S & F in replacement of unserviceable MCB FP 415 volts,short circuit breaking capacity,Icn 10 kA, 'C' Curve suitable for fixing in MCB DB of capacity 63 amps complete all as specified and directed.Make - IndoAsian cat ref no 811152 or equivalent in Hager or Schneider / Havells as approved.
S & F in replacement of unserviceable MCB DP 240 volts, short circuit breaking capacity,Icn 10 kA, 'C' Curve suitable for fixing in DB of capacity 63 Amps complete, all as specified.Make : Indo Asian cat Part No-811176 or equivalent make in Havells/L& T/ Hager or Schneider / Havells as approved.
S & F in replacement of unserviceable MCB DP 240 volts, short circuit breaking capacity,Icn 10 kA, 'C' Curve suitable for fixing in DB of capacity 40 Amps complete, all as specified.Make : Indo Asian cat Part No-811174 or equivalent make in L& T/ Hager or Schneider / Havells as approved.
S & F in replacement of unserviceable MCB SPN 240 volts, short circuit breaking capacity,Icn 10 kA, 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811136 to 811151 or equivalent in Hager or Schneider / Havells as approved.
S & F in replacement of unserviceable MCB SP 240 volts, short circuit breaking capacity,Icn 10 kA , 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811114 to 811053 or equivalent in Hager or Schneider / Havellsas approved.
Supplying,fixing,testing and commissioning in replacement of LT panel board outdoor factory made kiosk cubbical type, dust & vermin proof of suitable size (1.65x1.0x0.50mm) Ip class protection made of 3 mm thick CRCA sheet and angle iron 50x50x6mm frame including power coating complete with locking arrangement mounted on PCC Plate form 100 mm thick made out of PCC 1:3:6,100 mm thich, 1 mtrs all round the panel board complete with the following items housed in :- (i) Incoming :- (a) MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity , 35/36 KA with adjustable thermal magnetic setting, Qty – 01 No.(Make:Legrand/Schnieder/Siemens/L&T/Indo Asian/Havells) (b) Digital Ammeter 3 Phase AC 0 – 400 Amps, with 3 current transformer of suitable ratio and capacity Qty -01 No. (c) Indicating lamps LED type for three phases -R Y B of 3 Nos, (d) Digital Voltmeter 3 Phase AC 0 – 500 Volts.Qty -01 No. (e) Bus-bar chamber having 3 nos insulated aluminium bus-bar of 800Amps rating and one No. bus bar of 400 Amps rating of suitable shape and size. (ii) Out Going (a) MCCB, 200 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity , 35/36 KA with adjustable thermal & fixed magnetic setting, Qty – 01 No.(Make: Legrand/Schneider/Siemens /Havells/HPL/Indo Asian) (b) MCCB, 100 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity, 25 KA with adjustable thermal & fixed magnetic setting, Qty – 02 No.(Make: Legrand/Schneider/Siemens /Havells/HPL/Indo Asian)
Note : (i) The contractor shall submit proposed drawing of the panel interlia mentioning make of switchgears to be incorporated alongwith name of panel manufacturer for approval of GE before manufacturing. (ii) The quoted rate is inclusive of the cost of danger notice plate of suitable size and marking of letters with PVC sheet/ Stickers such as incoming and outgoing and capacity of breakers etc. (iv) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (v) The bottom of panel shall have minimum 45cm height from existing ground / floor level.
Supplying,fixing,testing and commissioning in replacement of LT panel board outdoor factory made kiosk cubbical type, dust & vermin proof of suitable size (1.30x1.0x0.50mm) Ip class protection made of 3 mm thick CRCA sheet and angle iron 50x50x6mm frame including power coating complete with locking arrangement mounted on PCC Plate form 100 mm thick made out of PCC 1:3:6,100 mm thich, 1 mtrs all round the panel board complete with the following items housed in :- (i) Incoming :- (a) MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity , 35 KA with adjustable thermal magnetic setting, Qty – 01 No.(Make:Legrand/Schnieder/Siemens/Havells) (b) Digital Ammeter 3 Phase AC 0 – 200 Amps, with 3 current transformer of suitable ratio and capacity Qty -01 No. (c) Indicating lamps LED type for three phases -R Y B of 3 Nos, (d) Digital Voltmeter 3 Phase AC 0 – 500 Volts.Qty -01 No. (e) Bus-bar chamber having 3 nos insulated aluminium bus-bar of 800Amps rating and one No. bus bar of 400 Amps rating of suitable shape and size. (ii) Out Going (a) MCCB, 200 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity , 35/36 KA with adjustable thermal & fixed magnetic setting, Qty – 02 No.(Make: Legrand/Schneider/Siemens/Havells) (b) MCCB, 100 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity , 25 KA with adjustable thermal & fixed magnetic setting, Qty – 02 No.(Make: Legrand/Schneider/Siemens/Havells)
Note : (i) The contractor shall submit proposed drawing of the panel interlia mentioning make of switchgears to be incorporated alongwith name of panel manufacturer for approval of GE before manufacturing. (ii) The quoted rate is inclusive of the cost of danger notice plate of suitable size and marking of letters with PVC sheet/ Stickers such as incoming and outgoing and capacity of breakers etc. (iv) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (v) The bottom of panel shall have minimum 45cm height from existing ground / floor level.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron strip 32x6 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (1991) and specified including provision of galvanized iron strip 32x6 mm dia protected by 40mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.
S & F in replacement of unserviceable MCCB enclosure suitable for existing any make, any type, any pole of MCCB 100 TO 250 Amps complete, all as specified.Make -IndoAsian cat ref no 811122/24/26/27/28/29 or equivalent in Hager or Schneider / Havells as approved.
Fixing properly existing hanging Sheet steel enclosure of SPN/TPN DB by fixing / flushing to wall by cutting niche & make good to the disturbed wall surface as per existing complete , all as specified.
shivrefrigeration
JS CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .