| 1 | L1₹7.8 LAccepted-AOC 00 JAI BHAWANI COMPLEX MAIN ROAD SADAR WARD JAGDALPUR BASTAR CHHATTISGARH 494001 UDYAM CG 01 0003803 | BASTAR | CHHATTISGARH | 494001 | ₹7.8 L Quoted ₹7.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹9.1 L+₹1.3 L (16.0%)Rejected-Finance | ₹9.1 L+₹1.3 L (16.0%) | L2 | Rejected-Finance Other than L1, hence rejected |
Tender Value
Refer Docs
EMD Value
₹15,400
Closing Date
29 Oct 2020, 6:00 pmClosed
AGE (I) Naya Raipur
Military Engineer Services Assistant Garrison Engineer (Independent) Naya Raipur c/o HQ COSA, Near International Cricket Stadium Atal Nagar, Naya Raipur, Raipur (CG)-492101
PROVN OF TILING FOR WASHING POINT OF 155 INF BN (TA) JAK RIF, PROVN OF DRAIN OUTSIDE BLDG NO. T-40 OF 155 INF BN (TA) JAK RIF, PROVN OF AIR CONDITIONER FOR TELE PHONE EXCHANGE AT KOTA AND NAYA RAIPUR, PROVN OF INTERLOCKING TILES PATH AT ENTRANCE OF
2020_MES_376497_2
8400/267/E8
Open Tender
Civil Works
Item Rate
120 days
AGE (I) Naya Raipur
Please refer tender documents
7 documents required · 7 mandatory
₹500
AGE (I) Naya Raipur
₹15,400
5 Nov 2020
15 Oct 2020
31 Oct 2020
15 Oct 2020
29 Oct 2020
15 Oct 2020
Amount
Sch 'A' Part-I
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed by Engineer-in-Charge.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface laid over screed bed 15 thick in CM 1:4 complete all as specified and directed..
M&L for glazed ceramic coloured tiles 350 x 250x 7mm/450x350x7 mm thick on vertical surfaces such as skirting dados set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM (1:4) complete all as specified & directed
Sch 'A' Part-II
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in loose/soft soil complete all as specified and as directed.
M & L for PCC 1:4:8, type D-2 (using 40mm graded aggregate) as in foundation, mass concrete, sub base etc complete all as specified and directed.
M&L brick work with fly ash brick modular size in cement mortar 1:4 straight or curved on plan exc 6m mean radius complete all as specified and directed
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone agg) in channel & drains.
M&L for pcc 1:2:4 type B1 using 20mm graded stone aggregate in coping complete all as specified and directed
M&L 15mm thick rendering on fair faces of brick wall in CM 1:6 on fair face of brick work or concrete surface finished the surfce even & smooth without using extra cement complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated material n exc. 50mtr and depositing where directed at a level n exc. 1.5mtr above the starting point complete all as specified and directed.
M&L for extra froming fair finished in drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitered/stopped ends etc (inner girth only measured).
M & L for precast cover slab of RCC (1:2:4) type B-1 including form work set in cement mortar (1:4) and all as directed.
M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spiarally for hooping for columns, plinth beam etc, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia.
Sch 'A' Part-III
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 copper wound TR, BEE 5 star rated fixing with necessary braket/stand all as specified and directed by engr-in-charge
Supply and fixing of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 volt 20 Amps all as specified and directed by engr-in-charge.
Sch 'A' Part-IV
Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 copper wound TR, BEE 5 star rated fixing with necessary braket/stand all as specified and directed by engr-in-charge
Supply and fixing of voltage stabalizer sutaible for 1.5 TR AC with copper wound of 5 KVA all as specified and directed by engr-in charge
Sch 'A' Part-V
Excavating over areas, n. exc. 1.5 m deep and getting out in any type of soil
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5km above the starting point
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
hardcore of gauge n.exc 63 mm, deposited spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface
M & L 100 mm thick cement concrete type D2, 1:4:8 ( 40 mm graded aggregate) finished rough as in flooring.
M&L sand cushioning for paver blocks
M & L Machine Pressed precast concrete interlocking paver block with grey Cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade including filling of joints with sand watering complete and ensuring its proper interlocking all round the pavement / floor complete all as specified and directed.
M & L for providing, cement concrete type BO 1:2:4 (12.5mm graded aggregate) as in kerbs
Sch 'A' Part-VI
Supply and louring,fixing GI pipe Medium grade complete with nacessary fitting in bore of size 50mm all as specified and directed by engr-in-charge
Supply ,louring, fixing and testing of submersible pump three phase 415 v 10 HP suitable for 150mm dia bore well casing pipe size) with all accessories and as directed by engr-in-Charge
Supply and fixing of submersible copper cable for 6sqmm 3 core all as specified and directed by engr-in-charge
Supply and fixding of DOL starter for 10 HP submersible motor three phase 430 volt all as specified and directed by engr-in-charge
Sch 'A' Part-VII
Supply & fixing 'E' board (Everest make) 605 x 605 x 4 mm thick white prelaminated set & embosed, reinforced, designer ceiling board tiles of approved texture fixed at all height laid on hot dipped galvanised iron imposed grid with 24 mm wide T-section exposed flanges which shall be powder coated, white,.the frame work shall comprises of main runner made from 0.33 mm thick galvanised steel sheet and of size 24 x 32 x 300 mm and spaced at 1200 mm center to center fixed to be structural soffits by approved hangers at 1200 mm rawl center, hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level and fasteners and screws etc., the last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall, flush fitting of 120 mm long cross tee (with double stiching) to be interlocked between main runners at 600 mm center to center, size 1200 x 600 mm modules, cross tee longer than 600 mm to be supported independently on 600 x 600 mm moduler to be formed by fitting 600 mm long cross tee centrally between the 1200 mm cross tee. Tee, perimeter wall angle shall be of 0.45 mm thick GS sheet of size 19 x 19 mm and 300 mm long of white colour all as per manufacturer's instructions complete all as directed.
M&L Point wiring complete with 1.5 sqmm PVC insulated stranded copper conductor multistrand core cable drawn through and including rigid non metalic PVC conduit 20 mm dia ( medium grade with electric code of colour) , ISI marked with concealed conduit wiring including cutting chases and making good in CM 1:3 & white/colour wash to match existing surface, pressed steel terminal boxes modular type not less than 1.6 mm thick concealed in wall duly painted with two coat of black bituminous paint over a coat of red oxide primer, plastic laminated top sheet cover 2.8 mm thick of required size and colour for housing switches and sockets, 1.5 sqmm PVC insulated (green insulation) copper conductor as earth continuity cable drawn with wiring and connected to common earth dolly with modular boxes all as specified for -
(a) One light/Fan/Bell point controlled by one switch
(b) One socket out let 5 pin 5 Amp on independent board
(c) One socket out let 5 pin 5 Amp on same board
Supply and fixing of single pole & neutral 8 way double door 240 volt with 200 amps rated bus bar
Supply and fixing of MCB SPN 40 Amps 240 volt
Supply and fixing of MCB SP 6-40 amps 240 volt
supply and fixing of modular switches 1 way 6 A 1 module
Supply and fixinf of socket 6A 2/3 combined 2 module
supply and fixing of ceiling light 2'x2' 42 watt enviornment friendly new geneartion maesthetically designede ultra modern ceiling mounting luminaries with high brightness SMD LEDs as light source suitable for Arm strong/grid ceiling with necessary connection with 3 core copper cable 0.75 sqmm all as specified and directed by engr-in-charge Make Havells/BAJAJ/Crompton/Phillips
Supply and fixing of submain wring alonwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface recessed as required with casing caping/PVC conduict as per site requirement of 2x4sqmm with1x 1.5 sqmm as earth wire all as specified and directed y engr-incharge
Sch 'A' Part-VIII
Material and labour installation and testing of Air Break switch gang operated HT 1100 Volt suitable for horizontal or vertical mounting fixed type complete triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 amps complete wish all accessories all as specified as directed by Engr-in-Charge.
Supply and fixing of lighting arresters explusion type complete with all fittings tranmission class discharge capacity 65 kilo Amp of 11000 volt complete all as specifiede and directed by engr-incharge
Earthing with Galvanised Iron Earth Plate Electrode 600X600X6mm size buried directly in Ground vertically at a depth not less than 2.25 METRE below Ground Level with the Top Edge of Earth Plate at a depth not less than 1.50 METRE below Ground Level connected to GI Strip 32X6.0mm as Earth Lead by means of Bolts, Nuts, Check Nuts and Washers of Galvanised Steel, Earth Plate Electrode surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers not exc. 150mm thick, Aluminium Strip protected with and including Galvanised Iron Pipe 40mm Bore (dia) Light Grade, upto 1.0 METRE above the Floor Level of the Building where Main Switch/DB situated including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 540X540X50mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion including Taking down Unserviceable Earthing, complete all as specified and as directed.
Supply and fixing of earth continutity conductor or main earthing lead fixed to wall on battern or recess or chases or buried in ground or drawn in conduict/pipe ot fixed to poles aor any other indicatede situation for loop earthing etc as required32x6mm galvanised iron strip all as especified and directed by engr-in-charge
m/s ramanuj singh and sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .