Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | ₹46.7 L | L1 | Accepted-AOC AOC accepted. |
| 2 | L2₹48.4 L+₹1.6 L (3.48%)Rejected-AOC 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | ₹48.4 L+₹1.6 L (3.48%) | L2 | Rejected-AOC AOC rejected. |
| 3 | L3₹49.1 L+₹2.4 L (5.10%)Rejected-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | ₹49.1 L+₹2.4 L (5.10%) | L3 | Rejected-AOC AOC rejected. |
| 4 | L4₹53.0 L+₹6.3 L (13.4%)Rejected-AOC | ₹53.0 L+₹6.3 L (13.4%) | L4 | Rejected-AOC AOC rejected. |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
22 Jun 2022, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair/Maintenance of LT / HT OH Line, LT / HT Cables, LT Panels, MCCB, Main switches, HT VCB, Transformer and connected wks at Anarwala and MH Area under AGE E/M-II of GE Dehradun.
2022_MES_527844_1
8470/A/E8
Open Tender
Civil Works
Item Rate
334 days
GE Dehradun
Class D Cat b (ii)
8 documents required · 8 mandatory
₹500
Yes
GE Dehradun
₹99,800
26 Sept 2022
1 Jun 2022
24 Jun 2022
1 Jun 2022
22 Jun 2022
15 Jun 2022
Amount
M&L attending fault/ breakdown in LT Over Head line/ LT UG Cable/Service connection Cable/AC Connection due to any reason including removing of fault, and restoring the electric supply whole Anarwala area incl MH complete all as specified.
M&L for attending fault/ breakdown in HT Over Head line /UG Cable due to any reason like falling of tree branches, Bird hits, Cracking of Pin/ Disc insulator, breaking Over Head conductor complete including patrolling of LT line, Meggering, removing of fault, replacement of insulator any type, replacement of fuses and restoring the feeder by trained person complete all as specified and directed for following areas :- Notes : (i) All T&P & safety tools required to complete job are included in the unit rate. (ii) Unit rates also included the conveyance & communication facilities required to complete the job. (iii) Unit rates also included the HT/LT fault rectification round the clock (24X7hrs) as fault rectification Electricians party should have ITI Passed & sound knowledge/experience in HT/LT field. (iv) Unit rate also incuded the suitable current rating of tinned copper fuses HT/LT tapes, suitable size of Alumn thimble lugs etc for insulated of cables(HT/LT)
Patiya Pump house,ASC,127 EME incl jcos & fafa md accn and MH feeder (Approximate 8 KM go and back ) incl operation of VCB's installed at Sub stn MH Dehradun as and when required.
MAP Qtrs, KV school and 5gdr/414 fd hosp Feeder (Approximate 6 KM go and back )
Old Anarwala Md Accn/Map qtrs of upper camp and 3 Punjab incl AW Pump house feeder (Approximate 4 KM go and back )
S&F in replacement Indoor type single phase Epoxy cast potential transformer of ratio 33000/rt3/110/rt3,class .2 s, burden -25 VA,SV/HSV : 33/36 KV,ILV:70 KV, Connection : 'E' Earthed as per IS : 3156/1992 complete all as specified. MAKE : Adhunik yantra udhyog/CG/AE
S&F in replacement Indoor type single phase Epoxy cast current transformer of ratio 60/1, class : 0.2s,burden : 2.5 VA,STC : 13.1,KA : 1.0 sec,SV/HSV : 33/110V,ILV ; 70 KVp as per IS :2705, complete all as specified. MAKE : Adhunik yantra udhyog/CG/AE
S&F in replacement Indoor type single phase Epoxy cast current transformer of ratio 100/50/1+1A,class : 1.0,burden : 15 VA,STC : 18.4 at 1 Sec ,SV/HSV : 11 KV/110V,ILV ; 70 KVp as per IS :2705 , complete all as specified. MAKE : Adhunik yantra udhyog/CG/AE
S&F in repair of disc type Insulator (three disc in series assembly) porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nut bolts & washers for conductors working pressure 33000 volt grade complete all as directed incl disconnection and taking down existing complete all as specified. Make-Alstom/ABB/JAYSHREE/Southern Insulators/Mull & Co
S&F in repair of Insulator pin type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 33000 volt grade complete all as directed incl disconnection and taking down existing complete all as specified. Make-Alstom/ABB/JAYSHREE/Southern Insulators/Mull & Co
S&F disc type insulator (single disc assembly) porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nut for conductors working pressure 11000 volt grade complete including disconnection and taking down existing insulator complete all as specified and directed.
S&F Insulator pin type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 11000 volt grade complete including disconnection and taking down existing insulator complete all as specified and directed.
S&F Insulator Post type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 11000 volt grade complete with fuse clamps including disconnection and taking down existing insulator complete all as specified and directed.
M&L for spraying of agricultural based chemical inside the installation to control the growth of unwanted herb, shrubs etc incl cutting, removing the vegetation growth & surface dressing all around the installation yard/ transformer /LT panel Board area external only to keep installation always clean and tidy condition. Note:-Installation/Yard shall be kept clean by removing shrub/bushes etc throughout contract period and same shall be measured & paid only once after completion of contract.
M&L for removing the herb, shrubs, creepers etc on the LT/HT Poles the to keep poles/structures always clean and tidy condition. Note:- All the Poles shall be kept clean throughout contract period by repeatedly by removing the grass / shrubs as many times reqd depending on the growth of grass measurement will be measured & paid only once throughout contract period only once.
S&F in replacement of existing unserviceable control cable including laying or fixing with saddles or cable tie etc, jointing and testing LT PVC insulated copper conductor armoured electric power cable ISI marked with multistranded copper conductor heavy duty 1100 volts grade of 2.5 Sq mm 4 core complete all as specified and directed incl disconnection and taking down existing complete.Make: Havells/Polycab/Finolex/Simens.
Supply & fixing powder coated or hot dipped GI preforated type cable trays of size 100mm wide x 40mmx1.6 mm thick fixed to wall or iron gantery inclding all the try accessories,supports,bends,ankor fasteners,GI hardware etc
M&L for servicing 33 KV yard structure complete including replacement unserviceable jumper, sleeves vice type conductor, bolt nut and washers connecting lugs / thimble knife contact, PG clamps applying petroleum jelly to the moving as well as fixed contacts tightning all the connection for its smooth functioning preparing old painted surface of this structure such as poles, cross arms, bracing supports, clamp and back plate complete painting of two coats of anti corrosive weather proof heat resistant aluminium paints over a coat of red oxide zinc chrome primer and phase marking of post insulators, GOD, lightening arrester, CT,PT etc with red, yellow blue paint on all equipments inside the MRS all as directed at site by Engr-in -charge. Note: No extra payment will made for the spares reqd to keep the yard structure in satisfactory functional throughout contract period other than given in schedule complete all as specified and directed.
Supply & filling the new transformer oil of rupturing capacity 50KV for 60 Sec for topping up to required level of transformer complete all as specified and directed. Make: Savita/Poweroil/Castrol
Supply and fix in repair transformer breathers transparent of standard size suitable for 3.15 MVA transformers 33/11 KV volts cast alluminium transparent type including removing the existing u/s one complete all as specified.
Filtration/dehyderartion of the existing transformer oil at site of any make of transformer and capacity upto required dielectric strength as per IE rules and refilling in the transformer upto required level complete. (The diectric strength should not be less than 50 KV after filtration process)
M&L for replacement of old unserviceable LTstuds ,bushing complete set incl synthetic rubber gasket,stud, nut bolt & washers of existing size(set of three) by opening up of top lid with replacement tank cover complete gasket set as per existing one up to 500 KVA Cap transformer and making transformer leak proof complete all as specified and directed.
M&L for replacement of old unserviceable HT studs ,bushing complete set incl synthetic rubber gasket,stud, nut bolt & washers of existing size(set of three) by opening up of top lid with replacement tank cover complete gasket set as per existing one up to 500 KVA Cap transformer and making transformer leak proof complete all as specified and directed.
Supply & Fixing in replacment of aluminium body silica gel breathers of standard size suitable for 400 to 500 KVA Transformers 11KV/433 volt transparent type including removing to existing unserviceable one complete all as specified
Supply & Fixing in replacment of aluminium body silica gel breathers of standard size below 400 KVA Transformers 11KV/433 volt transparent type including removing to existing unserviceable one complete all as specified
Supply & Fixing in replacment Transformer oil temprature guage of standard size suitable for 100 to 500 KVA Transformers 11KV/433 Volts analogue type including removing the existing u/s one complete all as specified
S&F in replacement of one set of 3 Pole micro processor based feeder protection relay with instantaneous 2 Nos over current (50, 50N) element and 1 No Instantaneous earth fault (50, 50N) (o/c setting 50% - 200% and earth fault setting 20 % - 80% having large LCD display of all the parameters ie all three phase current at a time, type of fault, fault history etc operating voltage 110 Volts DC suitable for 11 KV indoor VCB panel including calibration of relay accordingly complete all as specified and directed incl disconnection and taking out existing complete and making necessary modification in existing wiring (if any required). Make ABB Cat No REF611 or Equvalent in Schneider/Siemens/Crompton
S&F in replacement auxiliary Relay 30 ABC,24 Volt DC ,PC : B33 08058 For 33 Volt Control & Relay panel ( tranformer cum feeder)
S&F in replacemet auxiliary Relay 30 DEF,24 Volt DC ,PC : B33 08058 For 33 Volt Control & Relay panel ( tranformer cum feeder)
S&F in replcement supervision Relay for trip relay ,95 T,24 V DC,PC : XR VED 08999 for 33 Volt Control & Relay panel ( tranformer cum feeder)
S&F in repair/ replacement following parts of HT VCB 11 KV, AC 3 phase, 50 HZ indoor type & 33 KV Out door VCB for complete as per existing make all as specified and directed incl disconnection and taking down existing complete Make: Alstom/ABB HT VCB's
Spout set (set of three) shower and rose contacts.
Auxiliary switch.
Rotary switch.
Auxiliary Contactor.
Breaker Trip/close switch (TNC)
Closing Coil 110/30 DC volts.
Shunt tripping Coil 110/30 DC volts.
Relay (PLA/Defferencial etc) 30/110 V DC,6A 250 V AC
Tripping lever.
Charging lever.
Changing gear for VCB.
Indicator LED type lamp assembly 110/30 volts DC Make: Siemens/ L&T/ MEI/Legrand (R, Y, B).
Tripping pin.
Push Button.
Spring Charging Motor complete 220 Volts.
Space heater ,110 Watt,230 V
Thermostate for space heater
Vaccume interrupter bottle as per sample suitable for 11//33 KV VCB at MRS.
Ammeter 0-150 Amps CT ratio 150/1 Amps as per sample Make: AE/Schneider/Siemens/L&T
Voltmeter 0-150 Amps PT ratio 33/110V as per sample Make: AE/Schneider/Siemens/L&T
Voltmeter 0-150 Amps PT ratio 11/110V as per sample Make: AE/Schneider/Siemens/L&T
Digital 3 line display multifunction meter having features to measure Volt Ampere power factor active load reactive load etc.
S&F in replacement 3 Phase Vaccume Circuit Breaker (VCB trolly) switch gear as per existing make & model (ABB VInd), motorized as well as manually charged ,fully interlocked ,horizontal draw out,rated voltage 12 KV ,rated current 800 Amps,insulation level 28 KV/75KV pk,short circuit current rating 26.3 KA for 3 sec, opening & closing coil voltage 110 volt DC and spring charge motor 150 watts 230 volt, 50 HZ and testing complete. Make : ABB VInd or equivalent in Crompton/Schneider
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches exceeding 1.5m wide and not exc. 1.5m depth and getting out in any type of soil complete all as specified and as directed.
Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified and as directed.
Supply and laying dry river sand filling for cable protection in trenches/cable ducts complete all as specified and as directed. (Note : only punned thickness shall be measured).
M&L sub class B bricks well burnt locally available of size 23 x 11.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified.
Surface excavation not exceeding 15 cm deep including dressing up soil etc for laying of gravel in sub stn or switch yard complete all as specified and directed
M&L for 150 mm thick gravel 20mm graded packed in 33 or 11 KV out door sub stn yard complete all as specified & directed
Taking out of HT /LT cable ,11KV OR 1.1 KV of any size from ground or poles etc and testing for serviceability and kept aside for reuse including proper rolling, loading unloading, transportation etc complete all as specified and directed. Note:- Earth work for the same shall be measured and paid separately.
Laying only of existing serviceable cable HT/LT ,11KV OR 1.1 KV in ground retrieved against item No 40 here-in- before complete including unrolling, unloading, transportation etc testing connections complete all as specified and directed.
M&L PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundation, bases for Post/Pole/ FPB /Transformer plinth plateform etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
M & L PCC (1:3:6) type C-1 (with using 20 mm graded stone aggregate) as coping of pole/FPB/TFR plinth plateform including necessary form work as required complete as directed
Material and labour for fault detection in UG HT cable of any size any type at any depth with fault locator incl material T&P required for the same and testing complete all as specified and directed. Note 1- Joint, excavation laying only of cable shall be measured and paid seperately 2. Each fault shall be treated as one job and contractor have to address the said fault immediately.
Supply, laying & connecting XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3.0 core including fixing lugs, cable gland etc including bare conductor duly insulated with Pvc heat shrinkable sleeve 1.1 KV grade at both end complete all as specified and directed including taking out old u/s cable.
All as per item no 45 here-in-above but cross- sectional area 120 sqmm x 3core
All asper item no 45 here-in-above but cross - sectional area 185 sqmmx3core
M &L disconnecting and taking out old unserviceable damaged/burn out cable of any size & make and supplying, laying, jointing and testing LT underground cable, heavy duty cable of size 240 sqmm x 3.5 core, 1100 Volts, XLPE insulated and PVC sheathed, armoured, multi-stranded aluminium conductor cable conforming to IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable including cable gland and lugs etc at both ends incl disconnecting and taking out unserviceable damaged cable complete all as specified and directed. Note : Excavation, earth work, cable sand cushioning & cable protection shall be measured separately under relevant items of this schedule.
All as per item no 48 here-in-above but cross -sectional area 95 sqmm x 3.5 core
All as per item no 48 here-in-above but cross -sectional area 50 sqmm x 3.5 core
All as per item no 48 here-in-above but cross -sectional area 16 sqmm x 4 core
All as per item no 48 here-in-above but cross -sectional area 10 sqmm x 2 core
S&F 1100 voits grade of heavy duty of size 10 x2 core (two single core flat or circular) stranded coductor of caple pvc insulated aluminium conductor ,served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more then 1mtr apart incl 4mm suspension wire one twin core cable flat or circular complete all as specified.
S&F of Cable route indicator showing 11KV HT/ 1.1KV LT of oval shape min 65mm dia or higher size fixed on 25 mm equal angle 60 cm long complete inclding grouting the same in pcc of size 30cmx30cmx30cm complete all as specifid & directed
M & L in replacement for cable end jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
All as per Item No 55 here -in-before but 11 KV 240 to 300 Sqmm cable indoor type.
M & L in replacement for cable end jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
All as per Item No 57 here -in- before but 11 KV 240 to 300 Sqmm cable outdoor type.
M & L in replacement for straight through cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 sqmm including testing after jointing complete all as specified & directed.
All as per Item No 59 here -in- before but 11 KV 240 to 400 straight through type.
M&L in replacement for LT Cable,1.1 KV grade straight through jointing kit ,heat shrinkable type joint complete with jointing materials and accessories for 120 to 185 sqmmx3.5 core
M&L in replacement for LT Cable,1.1 KV grade straight through jointing kit ,heat shrinkable type joint complete with jointing materials and accessories for up to 95 sqmmx3.5/4 core
M&L in replacement for LT Cable,1.1 KV grade cable end jointing kit ,heat shrinkable type joint complete with jointing materials and accessories for 120 to 185 sqmmx3.5 core
M&L in replacement for LT Cable,1.1 KV grade cable end jointing kit ,heat shrinkable type joint complete with jointing materials and accessories for up to 95 sqmmx3.5 core
Dismantling air GOD vertical/Horizantal mounted including insulator and opening machnisum for servicing and repair to existing GOD switch with DO fuse of any size incl replacement of bronze blades post insulators etc complete all as specified and directed.
M & L for switch air break gang operated triple pole out door type 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on porcelene insulators (9 insulators) and frame with operating mechanism from ground level with earth switch and including locking arrangement complete all as directed Make :- Elpro/Pactil/jaipuriya
S & F horn gap type of fuses,expuision type single pole, 11KV mounted on six post insulators porcelene type with gun metal clamps and copper horn complete of 200 Amp including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed. Make :- Elpro/Pactil/jaipuriya
M & L in replacement for lightning arresters porcelene type 12 KV grade complete with all fittings, station class, discharge capacity 65 Kilo Amps complete all as specified and as directed incl taking down old u/s complete Make:- Siemens EL2 or equilent in ABB/ELPRO/GE/BHEL
Dismantling and taking out old unserviceable cross arms and M&L for cross arms, bracing, supports clamps back plates, gantry bay structure etc fabricated from structural steel section such as suitable I section channel ISMC angle iron and flat iron GI nut, bolt & Washers with welding, cutting, drilling hole etc for insulator bolts clamps in any shape and size including one coat of red oxide and two coats of epoxy heat resistant paint all complete all as specified and directed.
Dismantling existing steel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete shifting cost etc. and removing the old unserviceable rubbish etc complete all as specified and directed.
Fixing only Steel pole of any length & dia retreived against respective item no 70 incl loading,shifting,unloading errection in the vertical position all as directed & specified (Excavation and earth work and PCC for foundation channels, clamps ,nuts and bolts shall be measured and paid for separately)
Supply transportation up to and at site of work and erection of steel tubular swaged pole type 410 SP-55, 11 mtr long conforming to IS - 2713 in vertical position, applying two coats of aluminium paint over a coat of red oxide primer externally above ground level and a coat of anti corrosive below ground level and marking with alternate white and black paint strip 30cm wide total 5 Nos with synthetic enameled paint complete with cast Iron base plate , drilling of holes for cable entering and including taper plug complete all as specified and directed. (Excavation and earth work and PCC for foundation channels, clamps ,nuts and bolts to be measured and paid for separately).
S&F in repair of Aluminium conductor steel reinforced (ACSR) for over head line of any size stringing and jointing on poles fixed to insulator including, binding wires pointing sleeves, aluminium tap and PG clamp etc complete all as specified and as directed including taking out old u/s ACSR conductor any size and type ALL-IND/ ICC/ BHARAT CONDUCTORS/ NICCO/ INDIAN ALUMINIUM CO./ UJALA
M&L for Earth continuity conductor on main earthing lead fixing to pole wall or buried in ground including bending/welding as per site requirement for earthing extra as required necessary (beyond 7.5 mtr) of GI strip 32 x6 mm including welding and jointing 02 Nos Nut, bolt & washer etc all as directed incl disconnection and taking down existing complete.
M&L for Earth continuity conductor on main earthing lead fixing to pole wall or buried in ground including bending/welding as per site requirement for earthing extra as required necessary (beyond 7.5 mtr) of GI wire 8mm with protecton of 15 mm MG PVC pipe including welding and jointing 02 Nos Nut, bolt & washer etc with earthing point all as directed incl disconnection and taking down existing complete.
M&L for Earth continuity conductor on main earthing lead fixing to pole wall or buried in ground including bending/welding as per site requirement for earthing extra as required necessary (beyond 7.5 mtr) of Copper strip 32 x6 mm including welding and jointing 02 Nos brass Nut, bolt & washer etc all as directed incl disconnection and taking down existing complete.
M&L for Trimming/ prunning of tree branches upto 5 meters below & both sides to obtain clearance all around the LT over head lines / HT over head lines conductor upto 5 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as directed.
Supply and fixing danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white letters, figures and conventional skull bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20cm (11 KV) size complete all as specified and as directed.
Supply and lay in trenches fixed to poles, wall laid in floor GI steel tubing light grade,80 mm dia including fitting bolt, nut & washers etc or wooden rubber bushing at the ends of complete all as specified and directed incl disconnection and taking down existing complete all as specified.
All as per item no 79 here -in-before but 40mm dia
M&L for Painting to existing 4 pole structure after preparation of old surface of poles including pole fittings such as cross arms of any description, anti-climbing devices, nut, bolts, GO, DO, bracings clamps etc. by applying two coats of aluminum paint and synthetic enamel paint above coping complete all as directed at site by Engr in charge.
All as per item no 81 here -in-before but 2 Pole structure
All as per item no 81 here -in-before but Single Pole structure
Cutting existing road/hardstand of any type by using crow bar chisel uprto a depthof 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
M&L for transformer cable boxes or LT panel board cover/ panel doors etc made out of 3.0 mm CRCA sheet duly powder coated complete to make the system safe and secure complete including making hole nut bolts washer etc all as per site requirement complete all as specified and directed.
M&L MS plain black sheet of 1.60mm thick incl cutting in shape to cover cable duct in Sub Stns complete all as directed by Eng-in-charge
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32x6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR Part 1 including testing on completion all as specified and directed including demolition to existing earthing. NOTE 1. The unit rate includes for protection pipe 40 mm dia and GI strip 32x6 mm dia from top of earth plate up to 7.5 meter above ground level.
Discnnecting all electrical connections of transformers outdoor type up to 200 KVA HT 11KV/433 V,3 Phase 50 HZ with off load tapping and standard fitting,dismounting from plate form or structure(four/two pole) as directed,shifting of proposed site (with in juridistiction of GE DDN,reinstalling on plateform or proper load balancing as per engineering practice ,confirming to is 2026 including connected panel all as directed including making all arrangements (cranes,truck etc) for lifting and transportation complete all as specified. NOTE : Item rate incl necessary transport,tools & plant and labour ,lugs thimble PVC sleeves etc required for shifting ,installation,connection and commissioning of transformer.
Discnnecting all electrical connections of transformers outdoor type 315 KVA to 500 KVA HT 11KV/433 V,3 Phase 50 HZ with off load tapping and standard fitting,dismounting from plate form or structure(four/two pole) as directed,shifting of proposed site (with in juridistiction of GE DDN,reinstalling on plateform or proper load balancing as per engineering practice ,confirming to is 2026 including connected panel all as directed including making all arrangements (cranes,truck etc) for lifting and transportation complete NOTE : Item rate incl necessary transport,tools & plant and labour ,lugs thimble PVC sleeves etc required for shifting ,installation,connection and commissioning of transformer.
Discnnecting all electrical connections of transformers outdoor type up to 500 KVA HT 11KV/433 V,3 Phase 50 HZ with off load tapping and standard fitting,dismounting from existing position for tfr pinth plateform repairing and installing the same after repairing on plateform or proper load balancing as per engineering practice ,confirming to is 2026 including connected panel all as directed including making all arrangements (cranes,truck etc) for lifting and transportation complete NOTE : Item rate incl necessary lifting arrangements,tools & plant and labour ,lugs thimble PVC sleeves etc required for shifting ,installation,connection and commissioning of transformer.
M&L for Brick work with sub class 'B' bricks, well burnt, staight or curved on plan exc 6 mean radius built in CM 1:4 for constuction of plate form with steps for transformer etc complete all as specified.
M&L rendering 15 mm thick in CM (1:4) on fair faces of brick or cocrete surface finished even & smooth with out using extra cement duly painted with three coat of white wash complete all asspecified & directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles but excluding ashlar facings, dressed stonework and precast concrete articles.
M&L for repair to NECS make battery charger 24 volt including replacement of faulted card and any other component to make the system fully functional complete all as specified and directed.
M&L in replacement 2 volt, 200 AH SMF VRLA Maintenance free Battery complete all as specified. Make - Amara Raja Amaron or equaivalent in Exide/ Luminious.
M&L in replacement 12 volt, 65 AH SMF VRLA Maintenance free Battery complete all as specified. Make - Amara Raja Amaron or equaivalent in Exide/ Luminious.
S & F in replacement Change over switch , on load ,four pole ,320/315 amp, SS Enclosure Including complete connections with proper lugs with all arrangement to fixing into existing LT Panel or on wall with rain protection with 3mm ms sheet complete all as specified directed. Make : Havells/L&T/C&S
Supply,Installation, Commission and testing of type tested LT panel outdoor type LT(415 volts,50hz,3 phase 4 wire supply) factory assembeled,weather & vermin proof(protection class IP43) FABRICATED OUT OF 3.15mm thick CRCA sheet with front hinges opening ,rubber lining,locking arrangement,powder coated extermally and internally including cable glands of suitable to accommodate and inclding following including taking down old unserviceable panel complete all as specified and directed. (i)Aluminium busbar consisting of four no of capacity 300 amps duly insulated with heat shrinkable sleeve 1.1 KV grade mounted on heavy duty epoxy insulator . (ii) The minimum size of feeder piller box shold be 1000mmx600mmx500mm (iii) MCCB 415 volt ,200amps ,4pole,adjustable thermal magnetic release 80 to 100% ,35 KA (Ics=100%Icu)-01 (iv) The panel shoud be fixed on and including angle iron stand made out of 50x6mm thick 60 cm height duly grouted 30 cm below ground level in PCC all as directed. (v) Item rate includs excavation ,pcc &earth work reqd for taking out old existing cable incl lugs thimble &relaying the same. Make of MCCB : Legrand/C&S/Havells Make of LT Panel : Universal,Shalab India, Power system & Control
Dismantling fencing wire mesh,any type and in any position complete all as specified.
Dismantling RCC/ wood/ Iron posts or sruts any section ,including taking out embedded portion and making good disturbed ground complete all as specified
Excavation in post holes (or similer holes) each n exc 0.5 cum.getting out and removing surplus soil to a distance n exc 50m complete all as specified
S&fixing mild steel work such as in angle iron for posts,horns including flat iron fillets ,nut,bolts,10mm dia MS bars as in the bar fixed to fencing posts for fixing of chain link fencing ,securing its etc including necessary cuttings,drilling,bolting or reveting etc as per site requirement and other similer works complete mild steel ,conforming to Fe-290 Gde E-165
Supply only chain link fencing made of 4mm dia mild steel galvanised wire and 100x100mm mesh complete all as specified
Fixing only chain link fencing including line wires, any mesh,size and type to any any type to standards,rails,straining bolts etc including provision of binding wire complete all as specified
Taking down existing connection from LT Panel /Busbar chamber/Feeder Piller/Electric Poles/Building carefully (any capacity,any type) carring out repair work at site including replacement of unserviceable /defective screw/nut & bolts/washers/lugs/Spreaders/Hinges of doors/Repairt to locks& handles /Indication lamps/Meters/Cables glands/Busbar (Copper/Aluminium)etc rifixing the fittings in its original or other location after complete two coat of enamel paint over a coat red oxide primer after scrapping thorougly the existing correded paint ,dirt/dust,oil &grease with painting of inside & outside panel incl cleaning/scraping inclding removal of bushes,creapers and trimming of branches around the LT panel /busbar chamber/Feeder Piller/Electric poles inclding takingout fixing site complete all as specified and directed Note : (i) if any major repair is required , attending complaits and replacement of any nature in LT power network at any point and time,the major items ie MCCBs,ST through jont ,PCC etc shall be replaced with respective items of Sch A with paiad saparately (ii) Tools,ledder,vehicle required to carry out the work shall be provided by the contractor.
M&L for paintig to sub stn gates of size 230x170cm with two coat of synthetic enamel paint over a coat of red oxide primer after scrapping thorougly the existing correded paint ,dirt/dust,oil & grease complete all as specifed and directed
S&F in repair MCCBs in existing LT panel box /Feeder piller boxes of capacity 400 Amps 4pole breaking capacity 35KA Ics=100% Icu with thermal as well as magnetic balance adjustable setting type inclding taking down old unserviceable burnt out MCCB complete
S&F in repair MCCBs in existing LT panel box /Feeder piller boxes of capacity 200 Amps 4pole breaking capacity 35KA Ics=100% Icu with thermal as well as magnetic balance adjustable setting type inclding taking down old unserviceable burnt out MCCB complete
S&F in repair MCCBs in existing LT panel box /Feeder piller boxes of capacity 100 Amps 4pole breaking capacity 16 KA Ics=100% Icu with thermal as well as magnetic balance adjustable setting type inclding taking down old unserviceable burnt out MCCB complete
M/S K K ENTERPRISES
M/s SCHOLASTIC ENTERPRISES
Supra Electrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .