Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-Finance | ₹15.3 L | L1 | Accepted-Finance PLACE WORK ORDER |
| 2 | L2₹17.2 L+₹1.9 L (12.1%)Rejected-Finance | ₹17.2 L+₹1.9 L (12.1%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹18.8 L+₹3.4 L (22.4%)Rejected-Finance | ₹18.8 L+₹3.4 L (22.4%) | L3 | Rejected-Finance REJECTED |
| Sl No | Description | Qty | Unit | M/S K.K.ENTERPRISES L2 | HARIOM ENTERPRISES L1 | M/S H N ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00Items : | ||||||
| 1.01 | M&L Brushing neat cement slurry @ 3Kg/Sqm. | 200 | m2 | 2,554 ₹2,554 Lowest | 5,000 ₹5,000 | 5,800 ₹5,800 |
| 1.02 | M&L Plain cement concrete 1:2:4 (12.5 mm graded aggregate) 40 mm thick. | 200 | m2 | 34,200 ₹34,200 Lowest | 80,000 ₹80,000 | 60,000 ₹60,000 |
| 1.03 | M&L Rendering 15mm thick cement mortar plaster 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing with smooth finish without using extra cement in all position, including taking down damaged plastering on wall. | 200 | m2 | 55,400 ₹55,400 Lowest | 98,000 ₹98,000 | 60,000 ₹60,000 |
| 1.04 | M&L Preparation of old plastered or unplastered surfaces of external walls including brooming down or steel wire brushing; scrapping down smoke soots, moulds, moss and efflorescent salts and trading oil and greasy spots, including filling holes of nails and unevenness. Including Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. | 200 | m2 | 18,200 ₹18,200 Lowest | 28,000 ₹28,000 | 20,000 ₹20,000 |
| 1.05 | M&L Preparation and cleaning of horizontal/ vertical surfaces at any height (maximum 7.0mtrs) with mechanical grinder /wire brush to remove all protutions, oil, dirt, mud, dust, etc. The old coatings if any has to be removed completely. The cracks cavities below 3mm thick to be filled with poymeric filler and if cracks are beyond 3mm thick water resistant polymer adhesive paste to be filled after cutting / enlarging cracks in complete dry condition. The surface then to be air cured for 72 hours. Again same surface has to be rubbed/ polished with 150 number emery paper. After surface preparation dampness has to be checked with appropriate instrument and first coat of Polyurethane based polymeric compositions water resistance materials 2k properties tested and certified by National Chemical Laboratory has to be applied with roller/ brush over complete dry and clean surface. After leaving for 24 hours for air curing the applied surface to be rubbed with 320 number emery paper and bubbles/ unevenness if any to be repaired. Second coat of Polyurethane based polymeric compositions water resistance materials 2k properties tested and certified by National Chemical Laboratory has to be applied with roller/ brush which will be further air cured for 72 hours. | 3,144 | m2 | 16,06,584 ₹16,06,584 | 13,20,480 ₹13,20,480 Lowest | 17,29,200 ₹17,29,200 |
Tender Value
₹19.9 L
EMD Value
₹39,799
Closing Date
3 Jun 2026, 10:00 amClosed
The Chief General Manager
Ordnance Factory Varangaon
Repairs to cemented roof/terrace leakage by applying polyurethane based polymeric compositions Water resistance materials 2k properties tested and certified by National Chemical Laboratory, repairs to parapet wall plaster
2026_MIL_277456_1
RD2604/EO
Open Tender
Civil Works
Works
180 days
Ordnance Factory Varangaon
3 documents required · 3 mandatory
₹0
₹39,799
Yes
18 Sept 2026
14 May 2026
4 Jun 2026
14 May 2026
3 Jun 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Items : | |||||
| 1.01 | M&L Brushing neat cement slurry @ 3Kg/Sqm. | 200 | m2 | - | - |
| 1.02 | M&L Plain cement concrete 1:2:4 (12.5 mm graded aggregate) 40 mm thick. | 200 | m2 | - | - |
| 1.03 | M&L Rendering 15mm thick cement mortar plaster 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing with smooth finish without using extra cement in all position, including taking down damaged plastering on wall. | 200 | m2 | - | - |
| 1.04 | M&L Preparation of old plastered or unplastered surfaces of external walls including brooming down or steel wire brushing; scrapping down smoke soots, moulds, moss and efflorescent salts and trading oil and greasy spots, including filling holes of nails and unevenness. Including Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. | 200 | m2 | - | - |
| 1.05 | M&L Preparation and cleaning of horizontal/ vertical surfaces at any height (maximum 7.0mtrs) with mechanical grinder /wire brush to remove all protutions, oil, dirt, mud, dust, etc. The old coatings if any has to be removed completely. The cracks cavities below 3mm thick to be filled with poymeric filler and if cracks are beyond 3mm thick water resistant polymer adhesive paste to be filled after cutting / enlarging cracks in complete dry condition. The surface then to be air cured for 72 hours. Again same surface has to be rubbed/ polished with 150 number emery paper. After surface preparation dampness has to be checked with appropriate instrument and first coat of Polyurethane based polymeric compositions water resistance materials 2k properties tested and certified by National Chemical Laboratory has to be applied with roller/ brush over complete dry and clean surface. After leaving for 24 hours for air curing the applied surface to be rubbed with 320 number emery paper and bubbles/ unevenness if any to be repaired. Second coat of Polyurethane based polymeric compositions water resistance materials 2k properties tested and certified by National Chemical Laboratory has to be applied with roller/ brush which will be further air cured for 72 hours. | 3,144 | m2 | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
TERMSANDCONDITIONSRD2604.pdf
Tender Documents • 0.14 MB
ATTACHMENTS1.pdf
Other Document • 0.35 MB
BOQ_324032.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .