Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Competent committee approved the tender in favour of Ist Lowest Bidder | |
| 2 | L2₹19.8 L+₹2.5 L (14.7%)Rejected-AOC | L2 | Rejected-AOC Competent committee rejected the file due to higher rates |
Tender Value
₹16.1 L
EMD Value
₹16,110
Closing Date
30 Nov 2023, 5:00 pmClosed
SUPERINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE, KATJU MARG, BAREILLY
For Increasing Capacity of 11 Nos Existing Distribution Transformer and Installation of 33 Nos New Distribution Transformer of Various Capacity and Replacement of Damaged/Jarjar 11 KV VCB under Additional Business Plan scheme under EDD-II, Bareilly
2023_MVVNL_856712_1
68/EDCB/2023-24
Open Tender
Electrical Works
Item Rate
90 days
WORK
AS PER TENDER FORM
3 documents required · 3 mandatory
₹3,540
SE,EDC
₹16,110
14 May 2024
28 Oct 2023
1 Dec 2023
28 Oct 2023
30 Nov 2023
28 Oct 2023
Amount
The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-II Bareilly Approx. distance upto 60 Km. Including safe loading and unloading.
ST Pole 11 Mtr
PCC Pole 8.5 Mtr
ACSR Weasal Conductor
AB Cable 3x120 sqmm
AB Cable 3x95 sqmm
AB Cable 3x50 sqmm
11/0.4 KV 3 Phase 400 KVA T/F
11/0.4 KV 3 Phase 250 KVA T/F
11/0.4 KV 3 Phase 100 KVA T/F
11/0.4 KV 3 Phase 63 KVA T/F
11/0.4 KV 3 Phase 25 KVA T/F
LT Cable 1x120 sqmm
LT Cable 1x240 sqmm
LT Cable 1x400 sqmm
LT Cable 3.5x150 sqmm
LT Cable 3.5x70 sqmm
11 KV Incoming Panel (VCB)
11 KV Outgoing Panel (VCB)
Other Line material
Construction of T/F plinth 1.5x1.5x2 m3 for mounting 250 KVA T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect
Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation.
Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5 m length is inserted at the bottom. Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work Contractor will provide all material, Manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE)
Dismantling and removing of old and used/damaged 11 KV VCB (1 Incoming & Outgoing) in Control room including opening/cutting of power cable connection and earthing strip with dragging/cartage from control room to J.E. Store.
Erection/Installation of following new panel (VCB) in control room including grouting of Anchor bolt of Panel and making/repairing of pocket for cable to insert in panel from trench and fixing, taping of bus bar with wiring for PT. AC, DC connection including providing of AC & DC Supply.
11 KV Incoming Panel (VCB)
11 KV Outgoing Panel (VCB)
Providing cutting, fixing and welding of MS Strip from existing, earthing to new 11 KV VCB Complete in all respect, all material shall be arranged by the Contractor.
Dismentaling of 250 KVA Transformer as per norms complete in all respect
Dismentaling of 100 KVA Transformer as per norms complete in all respect
Dismentaling of 16 KVA Transformer as per norms complete in all respect
Dismentaling of 10 KVA Transformer as per norms complete in all respect
Mounting of 250 KVA T/F Transformers as per norms complete in all respect -
Mounting of 400 KVA T/F Transformers as per norms complete in all respect -
Mounting of 100 KVA T/F Transformers as per norms complete in all respect -
Mounting of 63 KVA T/F Transformers as per norms complete in all respect -
Mounting of 25 KVA T/F Transformers as per norms complete in all respect -
Fabrication & Installation of 11 KV Fuse set unit to be installed on midway of 11 KV Double Pole Structure. Material Detail for complete the work given below :- 1. MS Channel 100x50x2028mm) - 1 Nos (Provided by Contractor) 2. Iron Strip (50x5x305mm) - 3 Nos (Provided by Contractor) 3. 200 mm Fuse wire of required capacity - 3 lenght (Provided by Contractor) 4. Holding Clamps - 2 Nos (Provided by Contractor) 5. Aluminium Lug 70 sqmm - 4 Nos (Provided by Contractor) 6. Off Size Nut & Bolt - As Required (Provided by Contractor) 7- 11 KV Composite Pin Insulator - 6 Nos (Provided by Department) (Manpower & T &P would be provided by the contrator at his own cost)
Erection of Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms
PCC Pole 8.5 Mtr (Single)
ST Pole 11 Mtr long (Double)
PCC Pole 8.5 Mtr (Double)
Grouting of following Pole with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms
PCC Pole 8.5 Mtr (Single)
ST Pole 11 Mtr long (Double)
PCC Pole 8.5 Mtr (Double)
Laying of LT Cable 1x120 sq mm complete in all respect
Laying of LT Cable 1x240 sq mm complete in all respect
Laying of LT Cable 1x400 sq mm complete in all respect
Laying of LT Cable 3.5x150 sq mm complete in all respect
Laying of LT Cable 3.5x70 sq mm complete in all respect
The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms
Laying, Stringing & Sagging of Following Conductor complete in all respect
ACSR Weasal Conductor
AB Cable 3x120 sqmm
AB Cable 3x95 sqmm
AB Cable 3x50 sqmm
The work of digging of pits, erection of Stay Clamp, Insulator etc.
Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms.
Fixing of 3 Pahse Distribution Box complete in all respect
Fixing of 1 Pahse Distribution Box complete in all respect
Supply and Fixing of Following Material as per RESPO norms complete in all respect (would be Provided by contractor through approved vendors of Discom at his own cost)
Stone Pad 300x300x75 mm
Distribution Box Clamp
Cross Arm Holding Clamp
F Clamp with Nut & Bolt
Danger Board With Clamp
Barbed Wire
Aluminium Lug 120 sqmm with Nut&Bolt
Aluminium Lug 240 sqmm with Nut&Bolt
Aluminium Lug 400 sqmm with Nut&Bolt
Tailless Unit 400 Amp
Tailless Unit 600 Amp
Stay Clamp
Earth wire Clamp
P G Clamp
Holding Clamp for S/s
Holding Clamp for LT T-Off
Holding Clamp for M S Channel
LT Clamp With Nut & Bolt
Stay Insulator
LT Shackle Insulator
Nut & Bolt for Shackle Insulator
Piercing Connector
Safe back carriage of Following item (if any) from work site to C.B. Ganj store Bareilly approx distance upto 60 Km including loading & unloading.
11 KV VCB (Damaged)
11/0.4 KV 3 Phase 250 KVA T/F
11/0.4 KV 3 Phase 100 KVA T/F
11/0.4 KV 3 Phase 16 KVA T/F
11/0.4 KV 3 Phase 10 KVA T/F
M/S SAMAR ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .