Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹1.5 L+₹1,630 (1.10%)Rejected-AOC | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹1.7 L+₹21,098.06 (14.2%)Rejected-AOC | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹1.7 L+₹22,199.72 (14.9%)Rejected-AOC | L4 | Rejected-AOC L4 Bidder | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.7 L
EMD Value
₹2,000
Closing Date
21 May 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC I, Lucknow
Pareshan Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow
Work of dismantling of old existing structures and equipments and construction of 1 No. 33 KIV feeder bay etc. at 132 KV R.S. Ghat under ETD III, Lucknow
2021_UPTCL_585425_1
Short term e-tender03/2021-22
Open Tender
Electrical Works
Piece-work
30 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹236
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹2,000
8 Jul 2021
6 May 2021
22 May 2021
6 May 2021
21 May 2021
6 May 2021
180 days
Amount
Dismantling of following Equipments Of 33 KV BP Mavai & 33 KV Kotwadham Feeder Bay & 01 No. 33/0.4 KV S/S. T/F alongwith associated works like Opening of Jumpers, Cutting of Earthing, Opening of Cable Connections etc. including Shifting of Dismantled Items to Stores at the Sub Station :
Auxiliary Structures
33 KV Bus Isolator
33 KV Line Isolator
33 KV VCB
33 KV CT 400/200/1A
33/0.4 KV 250 KVA S/S. T/F
DO Fuse Set
Erection of following structure/Equipment including their shifting from storage place to Erection site with all other associated works for satisfactory completion of the job as per Technical specifications.
For 33 KV Feeder Bay:-
Auxiliary Structures
33 KV VCB
33 KV CT 800/400/1A
33 KV CT 400/200/1A
33 KV CT JB
33 KV Line Isolator
33 KV Bus Isolator
For 33/0.4 KV 250 KVA S/S. T/F:-
Auxiliary Structures
33/0.4 KV 250 KVA S/S. T/F
Installation of 33 KV Bus Isolator and DO Fuse Set including : (a) Shifting of equipment and associated structures from store to work site. (b) Erection of ALP & ABL structure including fabrication of the platform for DO Fuse set using old and used Tower Parts of 'Off' sizes and earthing of all structures. (c) Erection & fixing of 33 KV Bus Isolator, 33 KV Post Insulator and DO Fuse set. (d) Jumpering between 33 KV Main Bus to Bus Isolators, 33 KV Bus Isolator to Fuse Set and Fuse set to HV Side of Station Transformer by using PG Clamps / Connectors including bending & measuring of ACSR Panther Conductor.
For 33 KV Feeder Bay:-
Jumpering of Equipment with the help of ACSR Panther Conductor with main bus bar to Equipments with the help of suitable clamp to be provided by the Department with all other associated works for satisfactory completion of the job as per technical specifications ( 1 Job Each Bay )
Laying of control cables of following size as laid in the cable schedule in cable Trenches from 33 KV C&R Panel to Equipments in the switch yard along with saddling at every 750 mm Distance with M.S. Saddles of size 25*2 mm Carriage cable drums from stores to the laying side and shifting back to the store after completion of work, and all other associated works to complete the job. satisfactory.
2C X 2.5 MM SQ. Unarmoured
4C X 2.5 MM SQ. Unarmoured
6C X 2.5 MM SQ. Unarmoured
Termination of control cables laid as above as per cable schedule including making necessary holes in Gland plates providing cable glands of proper size and proper Ferruling on both ends of the each core of the cables, their termination and all other associated works to complete the job satisfactory as per technical specification .
Cutting , Straightening & Laying of 50 x 6 mm size M.S. Flat for Earthing for Main & Auxiliary Structures , Equipments to connect with main Earth mat at 2 Places with due excavation of 500 mm deep Trench , its back filling and painting of Earthing Strips with all other associated works for satisfactory completion of the job as per technical specifications And as per details below. (MS Flat will be provided by the department).
Earthing of Auxiliary Structures with 50 X 6 mm Size M.S. Flat
Earthing of Cable Trenches with 25 X 5 mm Size M.S. Flat
For 33/0.4 KV 250 KVA S/S. T/F:-
Termination of 300 mm dia 3 Core XLPE Power Cable From 33 KV Main Bus To Bus Isolator of 33/0.4 KV S/S. Transformer at Both Ends with all other associated works for satisfactory completion of the job as per technical specifications.
Jumpering of 33/0.4 KV S/S. T/F with the help of ACSR Panther Conductor with main bus bar to DO Fuse and DO Fuse to S/S. T/F with the help of suitable clamp to be provided by the Department with all other associated works for satisfactory completion of the job as per technical specifications.
Earthing of 250 KVA 33/0.4 KV Station Transformer's LV Neutral with 75 x 10 mm size M.S. Flat to connect with Delta after preparation of Delta Earthing by Using 3 meter long Electrode with 40/36 mm Dia M.S. Rod having 150mm long Conical shape as per Technical specification along with T/F Body, BBL Structure, and DO Fuse's Structures with 50*6 mm size M.S. Flat to Connect with Main Earth mat at 2 places. (MS Flat will be provided by the department).
Termination of Power cables as Existing laid including making necessary holes in Gland plates providing cable glands of proper size on S/S. T/F ends and all other associated works to complete the job satisfactory as per technical specification .
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .