| 1 | 1₹4.8 CrAccepted-AOC | ₹4.8 Cr | 1 | Accepted-AOC Lowest |
| Sl No | Description | Qty | Unit | M K KAVITHA L1 |
|---|---|---|---|---|
| 1.00Civil Work | ||||
| 1.00 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix) | 25 | cum | 1,514.13 ₹37,854.76 Lowest |
| 1.00 | Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge | 11.8 | cum | 3,576.7 ₹42,190.75 Lowest |
| 1.00 | Diamond wire saw cutting by roof slab, lifting in telescopic crane, lowering from third floor and breaking etc complete | 45.69 | cum | 16,611.37 ₹7,58,956.88 Lowest |
| 1.00 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | 78.31 | cum | 2,074.63 ₹1,62,460.13 Lowest |
| 1.00 | Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.Bwork | 648.78 | kg | 9.13 ₹5,923.36 Lowest |
| 1.01 | Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50
metres lead:Of area 3 sq. metres and below | 86 | each | 369.72 ₹31,795.92 Lowest |
| 1.01 | Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area beyond 3 sq. metres | 24 | each | 506.37 ₹12,152.88 Lowest |
| 1.01 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres spanand 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above | 9.77 | cum | 4,488.4 ₹43,847.18 Lowest |
| 1.01 | Dismantling tile work in floors and roofs laid in cement mortar including stackingmaterial within 50 metres lead.For thickness of tiles 10 mm to 25 mm | 3,253.99 | sqm | 73.9 ₹2,40,469.57 Lowest |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
15 Jan 2026, 5:00 pmClosed
The Managing Director, KTDC
The Managing Director, KTDC corporate office PMG Near Mascot Hotel Trivandrum
Upgradation and renovation of Hotel Samudra_Phase IV
2025_KTDC_802574_2
KTDC/EW/HS-Phase-4/UPG/25
Open Tender
Civil Works - Buildings
Item Rate
365 days
Hotel Samudra, Kovalam
Please refer Tender documents.
12 documents required · 12 mandatory
₹11,800
₹2 L
10 Aug 2026
1 Jan 2026
17 Jan 2026
1 Jan 2026
15 Jan 2026
1 Jan 2026
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix)
Demolishing R.C.C. work manually / by mechanical means including stacking ofsteel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge
Diamond wire saw cutting by roof slab, lifting in telescopic crane, lowering from third floor and breaking etc complete
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.Bwork
Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area beyond 3 sq. metres
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres spanand 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above
Dismantling tile work in floors and roofs laid in cement mortar including stackingmaterial within 50 metres lead.For thickness of tiles 10 mm to 25 mm
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Dismantling G.I./C.I pipes ( external work) manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer- in Charges: < br>Above 40 mm nominal bore
Dismantling and carefully stacking CPVC or PVC pipe of 32mm dia to 50mm dia etc. complete as per the directions of Engineer-in charge at site.
Dismantling and removing all sanitary and plumbing fittings of existing toilet such as wash basin, closet, taps, shower arms, health faucet, angle clock, bathtub etc. removing carefully stacking in convenient places pointed out by the engineer in charge for reuse including disposal of all debris outside KTDC premises and cutting and removing all projected parts of existing pipes and fittings etc.and making all the surfaces ready for fixing new fittings to wall tile etc.complete.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-incharge.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Providing and laying in position ready mixed or site batched design mix cementconcrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 toaccelerate / retard setting of concrete, to improve durability and workability withoutimpairing strength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades ofconcrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix ismore than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cementAll work above plinth level upto floor V levelConcrete of M25 grade with minimumcement content of 330 kg /cum
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Corrosion resistant steel (CRS|) bars of grade Fe 500D or more
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threadedfittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chasesand making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good thewall etc.32 mm nominal dia pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per irection of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 -External work- Exposed on wall
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipesincluding jointing with PVC solvent cement 110x110x110 mm dia Tee
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia Vent cowl
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
Constructing masonry chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. (non modular) bricksof class designation 7.5
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 90 mm dia Elbow
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 90 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
Providing and laying water proofing treatment in sunken portion of WCs, bathroometc., by applying cement slurry mixed with water proofing cement compoundconsisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to aircure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed withwater proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to aircure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing & fixing of white colour ceramic Table top wash basin of size420x320x135 mm (made of Jaquar Designer model No. ARS-WHT- 39901) andSingle Lever Tall Boy with 150mm Extension Body & 600mm Long BraidedHoses (made of Jaquar Designer model No. ARI-WHT- 39005B) etc. complete asirected by KTDC. Bottle Trap 32mm Size with 300mm & 190mm Long WallConnection Pipes & Wall Flange (made of Jaquar Designer model No. ALD-769L300x190 ), Angular Stop Cock With Wall Flange (made of Jaquar Designermodel No. CQT-23059) ( 2Nos for hot & cold water), 450mm braided hose with nipple, nut, O-ring rubber washer suitable for basin mixer ( 2Nos for hot & coldwater), CP brass waste coupling (made of Jaquar ALD-705L 130) including allaccessories for fixing wash basin etc.complete (quality and brand as approved by theKTDC) . The rate includes cost and conveyance of all materials , all labour chargesetc. complete (DAR-17.7.2 Based)
Supplying and fixing in position Robe hook - double coat hook (model No. AKP-35761P of Jaquar), including cutting & making good the walls ,cost and conveyance of all materials and labour charges for fixing etc. complete.(DAR-18.65Based)
Supplying and fixing in position C.P. Cloth Liner Retractable of Jaquar make-AHS-1565, including cutting & making good the walls ,cost and conveyance of allmaterials and labour charges for fixing etc. complete. (DAR-17.73.1 Based)
Providing and fixing Wall Hung WC with UF soft close slim seat cover, Hinges, Accessories Set, Size: 360x580x360 mm (made of Jaquar Designer model No. ARSWHT-39951UFSM) & Single Piece Slim Concealed Cistern with Floor Mounting Frame, Installation Kit and “P-Type” Drain Pipe ConnectionSet for Wall Hung WC(made of Jaquar Designer model No. JCS-WHT-2400FP)including Control Plate (made of Jaquar Designer model No. JCP-CHR-392415)Fixing of the above closet with stainless steel rack bolt (seam bolt ) white cap etc.complete with supply of Brass Pan connectors, noise reduction gasket &necessary fasteners. Providing water & Soil connections to the closet, togetherwith cutting and making good the walls and floors wherever required, quality andbrand as approved by the KTDC, etc. complete.
Supplying and fixing corner shelf or equivalent (Jaquar) of approved make includingcost, fixing charges etc omplete including connection pipe and all its accessories
Supplying and fixing PVC floor trap of required specifications as per site conditionsincluding charges for chipping floors and making good the floors after fixing the trap,etc. compete
Supplying and providing good quality cylindrical lock of approved make. The rateincluding all material cost labour charge etc completed. Premium Cylindrical Locks-Keyless
Supplying and fixing 5" gratings heavy duty of approved make including cost,fixing charge etc complete
Supplying and fixing SS Towel rack 600mm long (Jaquar Model No. AKP-35781PFS) with CP brass Screws and concealed fitting arrangement etc. complete. (DAR17.73.1 Based)
Supplying and fixing SS Towel rail 600mm long (Jaquar Model No. AKP-35711PS )with CP brass Screws and concealed fitting arrangement etc. complete. (DAR 17.73.1Based)
Supplying and fixing SS Towel Ring Square (Jaquar Model No. AKP-35721P)usingCP brass Screws and concealed fitting arrangement etc. complete. (DAR 17.72Based)
Supplying and fixing SS paper holder with flap guard (Jaquar Model No. AKP-35753PS) using CP brass Screws and concealed fitting arrangement etc. complete.(DAR 17.34.1 Based)
Supplying and fixing Soap Dish Holder (Jaquar Model No. AKP-35731P) etc.complete.
Supplying and fixing Health Faucet with 8mm Dia, 1 Meter Long Flexible Tube& Wall Hook (made by jaquar model no. ALD-573) connecting with Angular Stop Cock with Wall Flange (made by jaquar model no. ARI-39053) etc.complete.(DAR 50.17.1.5 Based)
Supplying and fixing Regular Body of Concealed Stop Cock Suitable For 20 mm PipeLine with Protection Cap (made by jaquar model no. ALD-089) with Exposed PartKit of Concealed Stop Cock & Flush Cock with Fitting Sleeve, Operating Lever& Adjustable Wall Flange with Seal (made by jaquar model no. FLR-5083NK)etc. complete (DAR 18.55.3 Based)
Supplying and fixing Overhead Shower 100mm Round Shape Single Flow (FacePlate Stainless Steel & ABS Body in Chrome finish) with Rubit CleaningSystem (made by jaquar model no. OHS-1661) with Shower Arm 20mm dia. & 300mm Long Round Shape with 900 Bend for Wall Mounted Showers with StainlessSteel Flange(made by jaquar model no. SHA-479L300S). (DAR 18.22.1 Based)
Supply and installation of shower cubicle (Jaquar made Model No. JSE-CHR-830G1216H19X ) using 8mm thick toughened glass as per the design. The rateincludes the cost and conveyance of all materials, labour charges, etc., mplete, asper the directions of departmental engineers at site and architectural drawings
Supplying and fixing Concealed Body for Single Lever Diverter 40mm Cartridgewith Button Assembly (Button On Top) (made by jaquar model no. ALD-065M) and Exposed Parts Kit of Diverter Consisting of Operating Lever, Cartridge Sleeve, WallFlange (with Seals) & Button Assembly Sleeve & Button (Compatible withALD-065M)( made by jaquar model no. ARI-9065MK).including supplying andfixing of Bathtub Spout with Wall Flange(made by jaquar model no. SPJ-10429PM),Overhead Shower 200X200mm Square Shape Single Flow (ABS Body ChromePlated with Gray Face Plate) with Rubit Cleaning System (made by jaguar model no.OHS-35497) and Shower Arm 400X25X25mm Square Shape for Wall Mounted Showers with Flange Also available (made by jaquar model no. SHA-455L400) etc.complete as per the directions of Departmental officers at site.
Supplying and fixing white glazed earthenware Urinal With Sensor Kit, Spreader And Fixing Accessories Set, Size:360X350X710mm (made by jaquar model no. URSWHT-13267S) using TW plugs and screws embedded in CM including connectionwith water supply inlet and waste water outlet etc. complete including cutting andmaking good the wall. (DAR 17.80 Based)
Supplying and Fixing Rectangular shaped urinal partition 450mm x 900mm sized and10mm thickness frosted glass with hrome Finish clamps etc complete as erdirection of Engg-in-charge (Jaquar made Model No : JSE-CHR-110US450X)
Providing and fixing false ceiling at all height including providing and fixing of framework made of special sections, power pressed from M.S. sheets and galvanized withzinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting ofangle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mmdia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangersof 25x10x0.50 mm of required length with nuts & bolts of required size and other endof angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at thespacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thickbottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm,at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel withconnecting clips made out of 2.64 mm dia x 230 mm longG.I. wire at every unction, including fixing erimeterchannels 0.5 mm thick 27 mmhigh having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed towall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wallscrews @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edges of theboard with recommnded jointing compound, jointing tapes, finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats ofprimer suitable for board, all as per manufacturer's specification and also includingthe cost of making openings for light fittings, grills, diffusers, cutouts made withframe of perimeter channels suitably fixed, all omplete as per drawings, specificationand direction of the Engineer in Charge but excluding thecost of painting with:12.5mm thick tapered edge gypsum moisture resistant board
Providing and Fixing 15 mm thick densified tegular edged eco friendly lightweight calcium silicate false ceiling tiles of approved texture of size 595 x 595mm in true horizontal level, uspended on inter locking metal grid of hot dippedgalvanised steel sections (galvanising @ 120 grams per sqm including bothside) consisting of main ‘T’ runner suitably spaced at joints to get requiredlength and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm(Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre tocentre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mmand size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked atmiddle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting onperiphery walls /partitions on a Perimeter wall angle pre-coated steel ofsize(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help ofrawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230mm interval and laying 15 mm thick densified edges calicum silicate ceilingtiles of approved texture in the grid, including, cutting/ making opening forservices like diffusers, grills, light fittings, fixtures, smoke detectors etc.,wherever required. Main ‘T’ runners to be suspended from ceiling using G.I.slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mmlong dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clipsof size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’,bottom exposed with 24 mm of all Tsections shall be pre-painted with polysterbaked paint, for all heights, as per specifications, drawings and as directed byEngineer-in-Charge.
Scraping and cleaning old polished or varnished surface with sand paper
Polishing on wood work with ready made mat finish Melamine polish of approvedbrand and manufacture to the old polished wooden surfaces of doors, windows,etc.after scraping, cleaning, sand papering to smooth even finish etc. and applyingpolish successive coat to get a smooth finish including applying primary coat for fillerseater etc complete as per direction of Engineer-in - charge including cost and conveyance of all materials, labours etc complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exteriorprimer applied @ 2.20 kg/10 sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and laying water proofing treatment on roofs of slabs by applying cementslurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with waterproofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be lessthan 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarsesand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by watercuring for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tillingwith cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
Providing & laying on roof double groove Mangalore ridge tile of 20 mm thicknessandof size 16x10 inches on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand)
Providing and fixing on roof double groove MP tile of 20 mm nominal thickness of417x261mm size, on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand mixed with 2% integralwater proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1cement : 4 coarse sand) andfinished neat complete
Providing and fixing 12 mm thick frameless toughened glass door shutter of approvedbrand and manufacture, including providing and fixing top & bottom pivot & springtype fixing arrangementand making necessary holes etc. for fixing required door including Door handle, lockand floor spring etc all complete as per direction of Engineer-in-charge
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Granite of any colour and shadeArea of slab upto 0.50 sqm
Providing and fixing 11.53 mm laminated toughened clear glass( 5 mm toughenedglass + 1.53 P VB + 5 mm toughened glass) with approved frame work for top andbottom channels, verticalswhere ever it touches masonry/partition as per manufacturer specification. The topchannel is supported till the original ceiling using adequate M S frame work and the bottom and side channelsare strongly anchoredto the floor/wall using chemical anchor fasteners with option for installing glass toglass joint with siliconeor other required accessories from FFL to required height as per the drawing andtechnical specification.The rate shall includes cost and conveyance of all materials, labour charges, lead, lift, ,all fixing arrangementand making necessary holes etc for fixing required fittings, all complete etc as directed by Engineer-in Charge. All toughened Glass shall be heat soaked
Providing and applying a protective coating system for steel beams and columnsincludes pre-cleaning by sanding, followed by 125- micron Jotamastic 80 AL as aprimer for corrosion resistance. 125-micron Jotamastic 80 AL Red will be used as theintermediate coat for durability and contrast, with a 60- micron Hardtop XP 7021topcoat for gloss retention and long-term protection, totaling 310 microns. Allcoatings will be applied with the proper thinner per manufacturer recommendations,including labor, materials,and equipment.
Supplying of wicker chair of size 600x600mm ( Specification :The frame isaluminum powder - coated and wrapped in synthetic hemp rope ) Including the costof all loading and unloading charges, conveyance, etc. as directed by departmental engineers.
Supplying of wooden chair with size of 500*500*750 mm or nearest available size asper the design provided pecification :Hardwood with teak wood finish. Cushionwith jute material.) Including the cost of all loading and unloading harges,conveyance, etc as Directed by Departmental Engineers.
Supplying of wooden table with size of 2400x750x750 mm or nearest available sizeas per the design provided Specification : second class teak wood ,finishing with two coats of melamine (glossy/matt finish) polish ) Including the cost of all loading andunloading charges, conveyance, etc as Directed by Departmental Engineers.
Supplying teak wood balcony table size of 600mm Dia or nearest available size as perthe design provided. Including cost of Italian marble top and finished with two coats of melamine (glossy/matt finish) polish and all loading and unloading charges, all conveyance, etc as Directed by Departmental Engineers.
Supplying Second class teak wood arm chair size of 605 X 630 X 775 mm or earestavailable size as per the design provided (Specification : cushion with rexin fabric.) Including the cost of all loading and unloading charges, conveyance, etc as Directedby Departmental Engineers.
Supply and fixing Bed Runner with Lining same as Curtain fabric as directed by theEngineer in charge.
Supply and fixing Cushion Cover of 450 x 450mm same fabric of Curtain as directed by the Engineer in charge.
Supplying and fixing the teak wood bed cot head board set with size of 3688 x 1200mm or the nearest available size as per the design.including the rates of upholstery, two coats of melamine (glossy/matt finish) polish, all loading and unloading charges,all conveyance, etc., as directed by Departmental Engineers
Repairing and modifying of second class teak wood wardrobe without any extra decoration per the design provided. Including rates of handles, hinges ,hanging rod ,finishing with two coats of melamine (glossy/matt finish) polish, all loading and unloading charges, all conveyance etc as Directed by Departmental Engineers.
Repairing and modifying second class teak wood luggage rack of size 600 X 1000X900 mm or nearest available size and replacing top surface with second class teak.Including the rates of finishing with two coats of melamine (glossy/matt finish)polish, all loading and unloading charges, all conveyance etc as directed byDepartmental Engineers
Dismantling old plaster or skirting raking out joints and cleaning the surface forplaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing and laying cement concrete in retaining walls, return walls, walls ( anythickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks,plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:1½:3 (1 cement : 1½ coarse sand (zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes with one step PVC solvent cement andtesting of joints complete as per direction of Engineer-in-Charge. oncealed work,including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75x63 mm dia Reducer
Providing and applying integral crystalline slurry of hydrophilic in nature forwaterproofing treatment to the RCC structures like retaining walls of the basement,water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 partsintegral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducingpermeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of the engineer in chargeThe product performance shall carry guarantee for 10 years against anyleakage.For vertical surface two coats @0.70 kg per sqm
Providing and applying integral crystalline slurry of hydrophilic in nature orwaterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 partsintegral crystalline slurry : 1 part water) for horizontal surfaces and applying thesame from negative (internal) side with the help of synthetic fiber brush. The materialshall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as perDIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The workshall be carried out all complete as per specification and the direction of theengineerincharge.The product performance shall carry guarantee for 10 years against anyleakage.For horizontal surface one coat @1.10 kg per sqm.
Providing and laying swimming pool tiles in floor with different sizes (thickness to bespecified by the manufacturer), with water absorption less than 0.08% andconforming to IS:15622, of approved brand & manufacturer, in all colours andshade, laid with cement based high polymer modified quick set tile adhesive (waterbased) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Basic price of tile is notless than 120 Rs/sft
Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of pproved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), excluding grouting the joints with white cementand matching pigments etc.(Payment for grouting of joints to be made separately),complete.Size of Tile 1200 x 600 mm.
Providing and laying Vitrified wall tiles in different sizes (thickness to be specified bythe manufacturer), with water absorption less than 0.08% and conforming to IS :15622, of approved brand & manufacturer,in all colours and shade, in skirting,riser of steps, laid with cement based high polymer modified quick set tile adhesive(water based) conforming to IS : 15477, in average 6 mm thickness, includinggrouting of joints (Payment for grouting of joints to be made separately). Size of Tile1200x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy groutmix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction ofEngineer-in-charge.Size of Tile 1200x600mm
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Elbow
Providing wood work in frames of doors, windows, clerestory windows and otherframes, wrought framed and fixed in position with hold fast lugs or with dashfasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for shutters for doors,windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled andglazed shutters for doors, windows and clerestory windows (Area of opening forpanel inserts excluding portion inside grooves or rebates to be measured), Panellingfor panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teakwood
Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of thickness 5.5 mm (weight not less than 12.5kg/sqm)
Providing and fixing aluminium die cast body tubular type universal hydraulic doorcloser heay type forr wooden shutter (having brand logo with ISI, IS : 3564,embossed on the body, door weight upto 35 kg and door width upto 900 mm), with necessary accessories and screws etc. complete as specified by the Engineer at site.
Supplying and providing good quality cylindrical lock of approved make. The rate including all material cost labour charge etc completed.
Filling floors of bathrooms with cement sand mixture in the ratio 1:15, compacting,etc. complete
Providing and fixing 500mm along with antiskid/non slip steps for extra safety alongwith anchoring fixtures complete. SS Ladder With 2nos Steps
Providing and fixing Floor inlet White ABS Plastic Floor inlet for concrete with S.S screws and regulate flow
Providing and fixing S.S. grab rail 32mm dia all around the pool with SS Flanges andFittings etc. complete
Providing and fixing Vacuum Head with Maintenance Accessories such as deep bagnet brush, curved brush, algae brush, wall side brush, telescopic pole, test kit etc.
Providing and fixing Vacuum Point
Providing and fixing S.S Main Drain 200x200mm
Providing and fixing Skimmer 15 ltrs with square lid
Providing and fixing 500mm along with antiskid/non slip steps for extra safety along with anchoring fixtures complete. SS Ladder With 3nos Steps
Taking out existing brick blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for whichpayment shall be made separately and stacking of serviceable material within 50metre lead as per direction of Engineer-in-Charge.
Providing and laying 60 mm thick factory made cement concrete interlocking paverblock of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and patternover and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil
Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying flamed finish Granite stone flooring in required design andpatterns, in linear as well as curvillinear portions of the building all complete as perthe architectural drawings with 18 mm thick stone slab over 20 mm (average) thickbase of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cementslurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-charge. a. Flamed finish granite stone slab Jet Black,Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainlesssteel dash fasteners, stainless steel bolts etc., of required size on the top of the floor orthe side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall beconsidered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement
Supplying and fixing window/door Heavy curtain of 2.15m or nearest Height ofgoodquality including cost of Main and Blackout cloth , all fixing arrangements ,Costof SS curtain Hooks etc.complete as per the directions of Deptl. Engineers atsite.Details for 3.00m
Stitching and fixing pleated sheer curtain into position using M-track of heavy dutyaluminium section of approved design and size, after dismantling the existing curtainrods. Rate including transportation, all material cost, stitching charges, labourcharges, etc. complete (rate excluding cost of fabric) – length of M-track to be considered for payment purpose only
Structural steel work riveted, bolted or welded in built up sections, trusses and framedwork, including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete.
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting,fixing in position and applying a priming coatof approved steel primer, including welding and bolted with special shaped washers etc. complete
Steel work for purlin/single section with G I pipes including cutting, hoisting, fixingin position and applying a priming coat of approved steel primer, including weldingand bolted with special shaped washers etc. complete
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoidscratches during transportation and should be supplied in single length upto 12 metreor as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/selftapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters andtrusses and including cutting to size and shape wherever required.
Supplying and fixing UPVC door with glazing/without glazing of size 0.80x2.00 m or nearest including all accessories like handles lock set etc complete as per direction
Supplying duroflex/sleepwell or approved equivalent pocketed spring mattress withsuperior quality foam, fabric, spring with proper edge support, tempering, border etcwith a minimum warranty of one year(210 x 180 x 20cm or nearest size to suite the Bed)
Supplying duroflex/sleepwell or approved equivalent pillows
Changing of upholstery fabric with superior quality fabric of approved design andcolour for Sopha full cover single seated including cost of 32 density foam of 1, 3 and4 inch thick , cora cloth , nails, adhesive, beeding rope etc, conveyance of all materials, all labour charges etc. complete as per the directions of Deptl. Engineers at site.
Changing of upholstery fabric with superior quality fabric of approved design and colour for Writing Chair including cost of 32 density foam of 2 inch thick , cora cloth, nails, adhesive etc, conveyance of all materials, all labour charges etc.complete as per the directions of Deptl. Engineers at site.
Changing of upholstery fabric with superior quality fabric of approved design and colour for Double seated Sopha including cost of 32 density foam of 1, 3 and 4 inch thick , cora cloth , nails, adhesive, beeding rope etc, conveyance of all materials, all labour charges etc. complete as per the directions of Deptl. Engineers at site.
Changing of upholstery fabric with superior quality fabric of approved design and colour for Head board Double including cost of 32 density foam of 2 inch thick , coracloth , nails, adhesive etc, conveyance of all materials, all labour charges etc.complete as per the directions of Deptl. Engineers at site.
Teak wood framed Wooden Bed side table of size 45x45x45cm or nearest size with double drawer and brass ornamental handles, locks and knob for all rooms duly finished of Teak wood frame as per the design provided. Wood surface shall be sanded smoothly with two coats of sealer applied and finished with two coats of polyurethane / melamine ( glossy/matt finish) in teak finish.
Repairing and modifying existing teak wood framed Wooden Bed side table of size 45x45x45cm or nearest size with double drawer and brass ornamental handles, locks and knob for all rooms duly finished of Teak wood frame as per the design provided. Wood surface shall be sanded smoothly with two coats of sealer applied and finished with two coats of polyurethane / melamine ( glossy/matt finish) in teak finish.
Repairing existing Teak Wood double Cot including Wood surface shall be sanded smoothly and two coats of sealer applied and finished with two coats of polyurethane melamine (glossy/matt finish) polish, all loading and unloading charges, all conveyance etc as Directed by Departmental Engineers.
Repairing and modifying existing Teak Wood writing table with attaching a carboard for 45L refrigerator with suitable brass handle and hinges, including Wood surface shall be sanded smoothly and two coats of sealer applied and finished with two coats of polyurethane melamine (glossy/matt finish) polish, all loading and unloading charges, all conveyance etc as Directed by Departmental Engineers.
Supplying LED TV stand including drawer for keeping remote as specified by the Engineer in charge at site.
Supply and installation of PVC fibre form board with suitable superior quality bracket.
Scarifying the existing granular road surface to a depth of 50 mm and disposal of scarified material within all lifts and leads upto 1000 metres.
Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniformlayers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means
Providing and applying tack coat with bitumen emulsion (RS) using emulsion pressure distributor at the rate of 0.25 - 0.30 kg per sqm on the prepared Granular Surface cleaned with mechanical broom.
Providing, laying and rolling of open graded premix carpet of 20 mm thickness with 0.27 cum of 12 mm departmental aggregates premixed with 12.96 kg of bitumen per10 sqm using penetration grade bitumen to required line, grade and level on apreviously prepared base, after priming the existing surface with 5 kg of bitumen (VG30) 10 sqm including mixing in a suitable plant, laying and rolling with a three wheel static roller of 80-100 KN capacity, finished to required level and grades,followed bya seal coat of 0.09 cum of 6 mm epartmental aggregates premixed with 8.64 kg of bitumen per 10 sqm. By Manual Means.
Filling up pot holes (cut and formed to regular shapes and all loose and defective materials removed) after supplying a prime coat of hot bitumen using 12mmdepartmental broken stone and compacting with power roller to get a compact surface.
Charges for dismantling the existing Switch board,pipe,wires,Light fittings, and all accessories etc. in rooms and passage including the related cable connected etc. completely and stacking the same as usable / reusable materials etc. complete. (4 labours per day)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 1.00 sq.mm 2 Run
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 X 1.5 sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 5 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 4 sq. mm
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant) 6A universal socket
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base and cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base and cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base and cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
Supply and Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant ) 3 module moulded plastic box on surface
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing following modular type USB Charger 1M 1000mA on the existing modular plate and switch box including connections but excluding modular plate etc. as required
Supply and Providing 16/20A Electronic Key Tag switch with card operation on existing modular plate, box etc. and giving connection etc. complete as required at site
Supply and providing modular type DND-MMR indicators with bell push (1+1) module (Both external and internal controls) on existing MS box and modular plate including giving connection etc. complete as required at site.
Supply of 8/9W Round Concealed CEILING LED fittings-COB (Warm) including all the accessories like clamps,screws and standard length connection leads etc. required for fixing and working on 240V, 50 Hz AC supply.
Supply , installation, testing & commissioning of the 4 Feet 20W LED Tube Light fitting including all the accessories like clamps,screws and standard length connection leads etc. required for fixing and working on 240V, 50 Hz AC supply (Havells)
Supply, installation, testing and commissioning of 5W/ Metre LED strip light (IP 20), 3000K colour temperature with drive suitable for indoor applications, including all connections, etc as required.Make - Philips LED Strip Skycove or equivalent.
Supply ,conveyance,installation,testing and commissioning of 6W LED Round recess mounting fittings in rooms, luggage rake and Toilet
Supply of 3W LED surface mounted led spot light fixture, colour temperature 3000K, Lumen output minimum 100lumen/Watt, CRI>80, including all necessary accessories etc as required. Make: Hybec or equivalent
Supply and installation of 7+/-2W led decorative type custom made table lamp in wood with fabric shadein linen with stiffene, E27 lamp holder , colour temperature 3000K, including all necessary accessories etc as required. (Note: The light fittings shall be in the range of Rs.2500- Rs.3000, custom made or branded)
Supply, installation, testing and commissioning of 3W LED flush or surface mounted foot light fixture, housing made of polycarbonate, 3000K colour temperature, working on 240V AC, suitable for indoor applications, including all connections etc. as required. Make - Legrand Myrius Next gen 679248 or equivalent.
Supply, installation,testing and commissioning of outdoor Wall fitting with 9w E27 LED bulb and giving connection as required. (Note: The light fittings shall be in the range of Rs.3750- Rs.4250, custom made or branded suitable for guest rooms)
Supply, installation, testing and commissioning of single pendant light fitting with suitable lamp and giving connection as required. (Note: The light fittings shall be in the range of Rs.2000- Rs.2500, custom made or branded suitable for guest rooms)
Supply of 7W led decorative wall light fittings with clear glass panel, colour temperature 3000K, including all necessary accessories etc as required. (Note: The light fittings shall be in the range of Rs.3750- Rs.4250, custom made or branded suitable for guest rooms)
Supply, installation, testing and commissioning of bed side Wall fitting with suitable lamp and giving connection as required. (Note: The light fittings shall be in the range of Rs.2750- Rs.3250, custom made or branded)
Supply, installation, testing and commissioning of custom made oval shaped framed mirror with antique brass finish, size: 500mm width x 1200mm height x 35mm projection with backlite led, colour temperature 4000K, including all necessary accessories etc as required. Make: Lumino or equivalent
Supply, installation, testing and commissioning of round shaped wall mounted adjustable swivel arm magnifying mirror with inbuilt led lighting, colour temperature 3000K, including all necessary accessories etc as required. Make: Lumino custom made or equivalent
Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: (Make: Havells Epic Pro BLDC)
Supply and Fixing the following modular switches and accessories in the existing front plates and giving necessary connections as required (RoHS compliant) Step Fan regulator - type 2 M
Supply and providing garden bollard fitting with suitable lamp and giving connection as required. (Note: The light fittings shall be in the range of Rs.1800- Rs.2200, custom made or branded)
Supply and providing outdoor wall facade light and giving connection as required. (Note: The light fittings shall be in the range of Rs.1000- Rs.1400, custom made or branded)
Supply and providing out door 2/3W LED step light and giving connection as required.
Supply and providing aluminium die cast 20 inch one side 6 watt LED bollard grey with top branded LED and high quality LED driver. Make: SUPERSCAPE K1018-M or equivalent
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
Supply,installation,testing and commissioning of 150mm light duty Exhaust fan working on 230V single phase AC supply of good quality and approved make to the existing opening /False ceiling making good damages with 3cx1.5sqmm FR PVC insulated copper conductor flexible cable etc as required
Supply and fixing the following Modular switch/socket on the existing modular plate and switch box including connections but excluding modular plate etc as required. RJ 45 Socket
Supply ,and fixing of modular type electronics chime in the existing switch board (Bell ding dong) working on 230 V AC supply
Supply and providing of push button type Telephone
Supply and providing 43 inch commercial LED Television of good quantity and reputed make
Supply of 1.0 Ltr or nearest higher capacity kettle
Supply of 45 Ltr or nearest higher capacity vapour compression type minifridge working on 230V AC supply
Supply installation testing and commissioning of swimming pool control panel:63A 4P Isolator-1no,63A ,100mA RCCB-1No.DP MCB 16A-3 Nos.Timer-3 Nos.3pole power contactor-3Nos, Auto ON/OFF switch-3Nos Powder coated control panel Box ,LED indicators, etc. complete as required at the site.
Charges for dismantling ,re-fixing, testing and commissioning of existing 3 HP swimming pool pump etc. complete at site.
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 4.00 sq mm
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 2 core 2.50 sq mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supply and fixing 15/18W under water LED light with stainless steel body, ultra thin fitted inside plastic ,100% leak proof model installed in level with tiles.(Make- Voltech, Spain or approved equivalent)
Supply and installation of connection box in ABS, size 18x18,water proof type.(Make-Voltech, spain or equivalent
Supply and fixing of 50VA/12V transformer 50W with polyester powder coated for dust free and long life, whisper quiet operation and X10 compatible, heavy duty power cord, Class H(180 deg.) insulation system and IP64 protection.
Supply of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the existing trench in one tier horizontal formation (in ordinary soil) 4 core 4 sq mm
Supply of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the existing trench in one tier horizontal formation (in ordinary soil) 4 core 6 sq mm
Supply of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the existing trench in one tier horizontal formation (in ordinary soil) 4 core 10 sq mm
Supply of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the existing trench in one tier horizontal formation (in ordinary soil) 4 core 16 sq mm
Supply of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the existing trench in one tier horizontal formation (in ordinary soil) 4 core 25 sq mm
Supply of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the existing trench in one tier horizontal formation (in ordinary soil) 4 core 35 sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Supply of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the existing trench in one tier horizontal formation (in ordinary soil) 4 core 50 sq mm
Supply of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the existing trench in one tier horizontal formation (in ordinary soil) 4 core 70 sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 6 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
Supply and laying of underground 0.5 mm 20 pair armoured telephone cable with HDPE insulation etc. as required
Supply and laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation 63/50 mm or nearest size
Supplying and Drawing unarmored PVC insulated and PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit. 10 pair
Supplying and Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit. 20 pair
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 core upto 6 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 50 sq. mm (35mm)
Charges for ground excavation (30 cm x 50 cm) for laying cable direct in ground and refilling the trench etc as required but excluding sand cushioning and protective covering
Supplying and providing of foundation of size 20 cm x 20 cm x 30 cm including plastering, excavation etc. as required for fixing of garden bollards
Supply, Installation, testing and commissioning of IP 66 rated weather proof Outdoor type junction boxes having dimension L x B x H (mm):- 130 x 180 x 77 mm with terminal having grey colour suitable for 2.5-6 sqmm cable (Make: Hensel, Model no: DK 1006 G)
Charges for dismantling the existing DBs and cable connected etc. completely and stacking the same as usable / reusable materials etc. complete. (4 labours per day)
Supplying and fixing IP 65/66 rated outdoor type isolator box for 4 Pole, 415 volts, 100 A isolator complete with connections, testing and commissioning etc. as required. (Make: Hensel, Model No: IB MI 4100 G)
Supplying and fixing IP 65/66 rated outdoor type isolator box for four pole, 415 volts, 63 A isolator complete with connections, testing and commissioning etc. as required. (Make: Hensel, Model No: IB KF 4063 G)
Supply and installation of Hensel make wall mounting type high quality Glass fiber reinforced Polycarbonate insulated Panel with IP 65 according to IEC 60 529, withprotection class II and internally embedded gasket made of polyurethane, flame retardant, self extinguishing with glow wire test at 960degC in accordance with IEC 60 695-2-11 UL subject 94; Impact strength IK 08(5 Joule) in accordance with DIN EN 50102. The Panel is in accordance with IEC 61439-1 & 2.The material should conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1 in accordance with IEC 60439-1. Bus bar ? 250A three phase, with provision for fixing the following (without switchgears) 100A FP MCCB, 25kA ? 1No, Digital multifunction meter -1No, 100/5A CL1, CTs- 3Nos RYB indication lamps ? 1Set, 2A SP MCB ? 3Nos, Outgoings- 32/63A TP+NL MCCB - 6Nos
Supply and installation of best quality vertical TPN DBs in accordance with IEC61439-3 made of high quality Polycarbonate PC - GFS IP 66 according to IEC 60 529, insulated-shock proof protection class II and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 960degC in accordance with IEC 60 695-2-11 UL subject 94; Impact strength IK 08(5 Joule) in accordance with DIN EN 50 102. The material should conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1 With 125A vertical TPN copper bus bar, Earth and neutral link, gland plate at top and bottom for cable entry suitable to fix metal glands. ( Including closing vaccant slots using Dummy ) 63A 8Way VTPN DB (8Way VTPN DB with provision for fixing 63A FP MCB/RCBO/RCCBm as incomer and 8Nos TP MCBs at outgoings.) Make: Hensel, Model no: FP VN 0800
Supply and installation of best quality vertical TPN DBs in accordance with IEC61439-3 made of high quality Polycarbonate PC - GFS IP 66 according to IEC 60 529, insulated-shock proof protection class II and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 960degC in accordance with IEC 60 695-2-11 UL subject 94; Impact strength IK 08(5 Joule) in accordance with DIN EN 50 102. The material should conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1 With 125A vertical TPN copper bus bar, Earth and neutral link, gland plate at top and bottom for cable entry suitable to fix metal glands. ( Including closing vaccant slots using Dummy ) 63A 4Way VTPN DB (4Way VTPN DB with provision for fixing 63A FP MCB/RCBO/RCCB as incomer and 4Nos TP MCBs at outgoings.) Make: Hensel, Model no: FP VN 0400)
Supply and installation of best quality TPN DBs in accordance with IEC61439-3 made of high quality Polycarbonate + Polystyrene IP 65 according to IEC 60 529, insulated-shock proof protection class II and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 700degC in accordance with IEC 60 695-2-11 UL subject 94; Impact strength IK 08(5 Joule) in accordance with DIN EN 50 102. The material should conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1 With Earth and neutral link, metric knock outs on top and bottom for cable entry. ( Including closing vaccant slots, using Dummy) 40A 6Way TPN DB, Provision for fixing MCB/RCBO/RCCB as incomer and 6Nos TP MCBs at outgoings (Make: Hensel, Model no: KV 9336)
Supply and installation of best quality TPN DBs in accordance with IEC61439-3 made of high quality Polycarbonate + Polystyrene IP 65 according to IEC 60 529, insulated-shock proof protection class II and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 700degC in, accordance with IEC 60 695-2-11 UL subject 94; Impact strength IK 08(5 Joule) in accordance with DIN EN 50 102. The material should conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1 With Earth and neutral link, metric knock outs on top and bottom for cable entry. ( Including closing vaccant slots using Dummy) 32A 16Way SPN DB, Provision for fixing MCB/RCCB as incomer and 16Nos SP MCBs as outgoing (Make: Hensel, Model no: KV 9118 M)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 WAY(4+12), DOUBLE DOOR
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 125 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Supplying and fixing 25A double pole contactor in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip
Supply, installation, testing and commissioning of 1 kVA, single phase input, single phase output UPS system along with necessary 12V SMF batteries for 30 minutes back up and powder coated rack including all accessories, cabling etc. as required.Make: Socomec or equivalent
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 2.65 mm copper conductor (12 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Supply and fixing following size earth bench, fixing on surface of wall/parapet using iron screws, bench having holes for connecting earth strip/wires, making good the damages, colour washing etc as required. 25x3x400 mm Cu earth bench.
Storage Tank for Hot Water System 2000 Ltr calorifier tank made of SS 304,16 SWG sheets,Tig welded and tested to withstand 1kg/cm2,duly insulated with 100 mm thick 48 kg/cm3 Rockwool and covered with Aluminium 22 SWG in waterproof manner, top manifold for inspection and cleaning. Temperature guage, air release valve, temperature and pressure release valve, electrical heating port with adequate heating coils for back up, with necessary mounting MS structural stand protected with epoxy paint and lifting hooks etc. complete
15 Tonne Heat Pump for Hot water System Air to water heat pump 55 kW or nearest output capacity and 12.3 kW or nearest input power requirement with rated output water temperature 55 deg C with 1380 L/Hr or nearest delivery capacity, working on 1 Phase/3 phase electrical power supply at ambient temperature range of 10 to 43 deg C, CFC free refrigerant, evaporator coil with coating for corrosion prevention, tube in tube copper / SS heat exchanger, expansion valves, expansion vessels, hot gas bypass arrangements, high efficiency fans, with necessary prewired digital control panel with BMS compatibility for automatic operation based on temperature requirement and all the required motor & starter circuits, motor overload & short circuit protection components, metering / controls / indication / sensors and related accessories with provision for cable entry of required size housed in a powder coated steel housing pre factory tested and certified. The rate circulation pump shall be included in the quote if necessary
Timer based operating Automatic re-circulation pumps (1 HP or nearest) as permanufacturer / OEM specification and standards
Centralized Control Panel for the operation of heat pump, circulation pumps and allother electrical accessories in the system in a dust tight, vermin proof Enclosure having provision for cable entry / outgoing as per standards with suitably rated MCB/MCCB as incomer and SP/TP MCBs as outgoing, starters, motor over load protection devices, Multi function meter to read current, Voltage and, Active power etc. The control connections shall be wired using PVC insulated 1 Sqmm copper conductor etc. complete using good quality and approved make of materials
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit, as required. 2X2.5 sq.mm + 1X2.5 sq.mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm
Supply and drawing bare earthing conductors of 3.15 mm copper conductor (No. 10 SWG) ( data for 25m ) along with wiring/ cables and giving earth connection asm required
Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes. 4 sq mm
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
Supply and providing CPVC pipe lines of required size having thermal stability for hot & cold water supply, ,brass valves,y strainers,line thermal insulation and all other fixing accessories required at site for the interconnection between tanks,heat pumps & re-circulation pumps etc.complete
Supply, installation, testing and commissioning of Modulating outdoor units, with inverter scroll compressors, special pre-coated fins, panel, corrosion resistant coated condenser, inverter based condenser fan , Vibration isolation pads, electrical & microprocessor panel, isolating valves and all the necessary accessories for proper functioning of the units
Supply, installation, testing and commissioning of Modulating outdoor units Remote and receiver
10 HP VRF SIDE Discharge Outdoor Unit Refent Joints
Supply, Installation, testing & commsssioning the VRF indoor units as per specification including Thermostats and all accessories as specified and as required
Supply,installation,testing and commissioning of carrier make cealing concealed FCU: Concealed cealing suspended chilled water coil 4 speed fan motor reversible design,V shaped insulated extended zinc coated steel drain tray,single skin,washable filter,return air plenumand electrical terminal box.with 25 mm valve packege & Digital thermostat
Supply,installation,testing and commissioning of carrier make cealing concealed FCU: Concealed cealing suspended chilled water coil 4 speed fan motor reversible design,V shaped insulated extended zinc coated steel drain tray,single skin,washable filter,return air plenumand electrical terminal box.with 25 mm valve packege & Digital thermostat
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 Thickness 1.00 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 Thickness 1.25 mm sheet
Supplying and fixing 50 mm thick Al foil faced resin bonded fibre glass insulation(on duct) of density 24 kg/cu.m or mineral wool insulation of density 44kg/cu.m after applying two coats of cold setting adhesive(CPRX compound) sealing all joints with self adhesive Al tape and covering with .63mmx19mmGI wire mesh netting and butting all joints and laced with GI wire complete and finally covered with one layer of Tar felt stuck with hot bitumen as per specifications and as required.(for outdoor applications). 50mm thick
Supplying & fixing of powder coated extruded aluminum Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
Installation Testing and Commissioning Charges (Lifting, Shifting , Installation, Pressure Testing with necessary supports/ Stands, and acessories as per consultant specifications ) of 6 HP Out Door Unit,4 TR Casset unit,1.5 TR Hiwall unit
Supply Installation, Testing & Commissioning of Refrigerant Cu Piping with as per OEM specifications VRF/VRV units 19 mm tubular nitrile rubber insulations
Communication Cabling between Indoor and Outdoor units- VRV/VRF system
Supply and laying of Electrical Cabling for Indoor units& vav units
Communication cabling for thermostats & Electrical cabling from Isolator to Outdoor Unit
R410a Refrigerant Gas for VRV/VRF system
Supplying, installation, testing of following Condensate Drain piping with 25 mm UPVC pipe and thermal insulation
Supplying, installation, testing of following Condensate Drain piping with 32 mm UPVC pipe and thermal insulation
Supply and installation of 1000 CFM Inline Fresh air Fan ( 10 ESP ) with canvass connection and vibration isolators with Ducting for fresh air
Control Valve Package 3-way Motorized 25 mm valve with actuator and strainer.with Digital Thermostat
Supply, installation, testing, and commissioning of HDPE (PE100) pressure pipe conforming to ISO 4427 / IS 4984 for chilled water application, PN10 (SDR 17), suitable for 0-40°C, including all necessary fittings, jointing by butt fusion/electrofusion, testing as per standard practice
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size- 50mm dia. (32mm thick fiber glass insulation) COST
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. Chilled water piping of nominal size-32mm dia. (19mm thick nitrile rubber insulation)
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable rubber based adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (32mm thick nitrile rubber insulation
Supplying,fixing,testing and comissioning of following valves,strainers, guages in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) 150mm
Supplying,fixing,testing and comissioning of following valves,strainers, guages in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) 100 mm
Supply, installation, testing & commissioning of Ball valve with 32mm thick Single layer of nitrile rubber inslation and matching flanges. Make: H- GURU. 25 MM BALL VALVE
Handling , Installation , Positioning , Pressure Testing and Commissioning of Ceiling Suspended FCU. Support must be provided with anchor blots not less than four numbers. Rubber pads should be provided to reduce the vibration
Supply, Installation, assembling, connection, testing & commissioning of Fiber Optic Single Mode 6 core armoured outdoor with all necessary accessories to comply the installation.
Supply and Installation of 16 Port Patch Panel with all accessories
Supply and Installation of 24 Port Patch Panel with all accessories.
Supply and installation of 6 Port LIU rack mounted
Supply and installation of Optical Fiber Media Convertor Single Mode Single Fiber (Type A & B)
Supply and installation of 16 Port Gigabit PoE Ethernet Switch rack mounted (with 2 normal uplink)
Supply and installation of 8 Port Gigabit PoE Ethernet Switch
Supply and installation of 25mm HDPE Pipe (Standard ISI ) with all accessories such as saddles etc and complete.
Supply, Installation, Testing and Commissioning of Wall mounted 6U Rack along with power sockets
Supply of 25mm PVC conduits/casing capping, (Standard ISI medium) with all accessories such as saddles etc and complete.
Supply and Fixation RJ 45 Connectors
Supply of Outdoor 8 Megapixel High Definition IP Bullet Camera of good quality & approved make with 3840 × 2160 30fps resolution,4 mm lens, minimum 30 m IR range, H.264 Compression, Video bit rate 32 Kbps~16Mbps, 2.54cm progressive scan CMOS,PoE (Power over Ethernet), 120db Wide Dynamic range, 3D Digital Noise Reduction,Dual stream, DC12V & PoE (802.3af), IP67 Weather Proof, day/night vision,Auto, scheduled Day/Night Switch,RoHS Compliance etc
Supply of Indoor 4 Megapixel High Definition IP Dome Camera of good quality & approved make with 2560 × 1440@30fps resolution,4 mm lens, minimum 30 m IR range, H.264 Compression, Video bit rate 32 Kbps~16Mbps, 2.54cm rogressive scan CMOS,PoE (Power over Ethernet), 120db Wide Dynamic range, 3D Digital Noise Reduction,Dual stream, DC12V & PoE (802.3af), IP67 Weather Proof, day/night vision,Auto, scheduled Day/Night Switch,RoHS ompliance etc
Supply and installation of 1Mtr Patch Cord
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required
Supply and installation of Wall Mount Wi-Fi Access Point (Dual Band)
Supply of High Definition 5 Megapixels (upto 8 mp) 32 channel NVR, HDMI and VGA output at up to 1920 x 1080 resolution,Network cameras can be connected with 80M/160M incoming and Outgoing bandwidth, Upto 2 SATA interfaces capacity up to 6 TB for each HDD, support network detection,including network delay, packet loss etc. optical mouse, IR Remote etc. Provision for easy backup to USB, built-in reporting of various alarms including hard disc errors, unauthorized logins, network conflicts etc, full feature remote access through IE Browser and with Client Software.(Black Metal Body)
Supply and installation of 4 TB Surveillance SATA Hard Disc.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.11 MB
FormA.pdf
Tender Documents • 0.02 MB
FormB.pdf
Tender Documents • 0.11 MB
GENERALCONDITION.pdf
Tender Documents • 0.21 MB
P.pdf
Tender Documents • 0.21 MB
Tnotification.pdf
Tender Documents • 0.48 MB
SC_AirConditioning.pdf
Other Document • 0.35 MB
AM_Electrical.pdf
Other Document • 0.06 MB
AM_cctv.pdf
Other Document • 0.06 MB
AM_AirConditioning.pdf
Other Document • 0.15 MB
SC_electrical.pdf
Other Document • 0.05 MB
BOQ_1383301.xls
BOQ • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .