| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC | ₹15.5 L | L1 | Accepted-AOC lowest |
| 2 | Rejected-Technical KEETHADATH HOUSE INKKUR P O 670503 | INKKUR | KANNUR | KERALA | 670503 | - | - | Rejected-Technical Rejected |
| Sl No | Description | Qty | Unit | PRADEEP KUMAR.V.K L1 | MANSOOR KEETHADATH L2 |
|---|---|---|---|---|---|
| 1.00Electrification | |||||
| 1.00 | 90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters | 15 | each | 28,053 ₹4.2 L | 29,971 ₹4.5 L |
| 1.00 | 90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 45 | each | 15,368 ₹6.9 L | 16,418 ₹7.4 L |
| 1.00 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | 375 | metre | 79 ₹29,625 | 84 ₹31,500 |
| 1.00 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm | 15 | metre | 148 ₹2,220 | 157 ₹2,355 |
| 1.00 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm | 90 | metre | 170 ₹15,300 | 181 ₹16,290 |
| 1.01 | 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size | 40 | metre | 283 ₹11,320 | 302 ₹12,080 |
| 1.01 | 90.16.2.5:Supply and laying of the following sizes of
B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.50 mm dia. G.I. pipe (medium class) | 24 | metre | 797 ₹19,128 | 851 ₹20,424 |
| 1.01 | OD180893/2025-2026: 24 Hours Timer for operating automatic ON-OFF function | 15 | each | 1,508 ₹22,620 | 1,611 ₹24,165 |
| 1.01 | OD180894/2025-2026: 32A, 2pole, AC I rated power contractor with INO+INC auxiliary contract & with Ac coil | 15 | each | 1,117 ₹16,755 | 1,193 ₹17,895 |
Tender Value
Refer Docs
EMD Value
₹41,468
Closing Date
31 Oct 2025, 11:00 amClosed
Nimil R T
Office of Assistant Executive Engineer LID EW LSGD Iritty Block Panchayat
Annual Plan-Iritty Block Panchayath Pro. No.72/26- Supply and Installation of Mini Mast in ST Unnathees at Aralam.-General Electrical Work
2025_LSGD_803725_7
DB/TEN/03/25-26
Open Tender
Electrical Works
180 days
Iritty
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
Yes
₹41,468
Yes
16 Jun 2026
24 Oct 2025
1 Nov 2025
24 Oct 2025
31 Oct 2025
24 Oct 2025
Amount
Electrification
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.16.2.5:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.50 mm dia. G.I. pipe (medium class)
OD180893/2025-2026: 24 Hours Timer for operating automatic ON-OFF function
OD180894/2025-2026: 32A, 2pole, AC I rated power contractor with INO+INC auxiliary contract & with Ac coil
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD183652/2025-2026: Provision for Horizontal road drilling for UG service cable from mast to KSEB LT post and per mission from PWD road and other related authority if required.
OD183648/2025-2026: Preparation charges for sketch, schematic diagram, load details etc, and submitted with test report to KSEB for further action.
OD183649/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 25 x 3mm brass bolt & nut
OD180895/2025-2026: Supply and providing 32 A HRC Fuse with 25 A Fuse link and giving connection on existing panel board.
OD180896/2025-2026:Supply and providing 32-A Neutral link mounted on DMC/ SMC base and giving connection on existing panel board.
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
OD189389/2025-2026:Supply & installation of dust and vermin proof, wall mounting, three phase syntax meter box (GS MB suitable size) as per site for fixing KSEB meter ,fuse units, CT, MCB, timer etc, hinged door construction , providing vision panel for the meter compartment, knock out for cable entry and exit etc.as required including fixing to wall / electric post etc. and making good the wall as required..
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
MANSOOR KEETHADATH (BID ID -2419709)
Bidder Name
PRADEEP KUMAR.V.K
MANSOOR KEETHADATH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1361163.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
viewsbd72.pdf
Tender Documents • 1.63 MB
BOQ_1361163.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid