Loading…
Loading…
Tender Value
₹8.3 L
EMD Value
₹20,652
Closing Date
17 Aug 2023, 4:00 pmClosed
Assistant Executive Engineer
Water Works Sub Division Kaloor Kochi 17
Improving water supply to Sree Narayana Road by laying 90mm PVC in Div 49 and 50 old of Kochi Corporation Improving water supply to Sree Narayana Road by laying 90mm PVC in Div 49and 50 old of Kochi Corporation Pipeline Work
2023_KWA_594565_1
CE(CR)/2824/2023-2024
Open Tender
Civil Works - Water Works
Percentage
30 days
old dn 49 and 50
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,825
₹20,652
11 Oct 2023
10 Aug 2023
18 Aug 2023
10 Aug 2023
17 Aug 2023
10 Aug 2023
10 Aug 2023 - 17 Aug 2023
Amount
Working Charges
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
OD110390/2023-2024:Taking connection from100 mm AC pipe to 90 mm PVC Pipe with saddle clamp with suitable packing and nut and bolt, PVC Specials etc complete as per the direction.
OD110421/2023-2024:Taking connection from newly laid 90 mm PVC Pipe with existing 63 mm PVC Pipe using the specials supplied by contractor and charges for earth work excavation etc complete as per the direction
OD110130/2023-2024:Taking water supply house connection from the existing 63/75/90 mm PVC pipe using saddle clamp, PVC MTA, elbow, etc. including earth work excavation, hire charge for tools, cost of materials & conveyance etc complete as per the direction of dept. officer.
100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
100.98.1008:Engaging Coolie.
100.98.1009:Engaging Fitter ( grade 1).
100.32.4:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 80mm Double Acting Air Valve.
Cost of Materials
100.98.213:Supply of PVC Pipe, 6kg/cm2, 90mm Dia.
100.98.450:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 80mm.
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
OD123440/2023-2024:90mm PVC Endcap (Rate adopted from Finolex Tradeprice list)
OD110444/2023-2024:Solvent Cement
OD125276/2023-2024:supply and fixxing of 90mm PVC Bend
Construction of Valve Chamber
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
SHAJU T S
Bidder Name
SHAJU T S
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_881568.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .