Tender Value
Refer Docs
EMD Value
₹79,000
Closing Date
6 Feb 2021, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
SPECIAL REPAIR TO 126 HF COMPLEX AT AF STN CHANDIGARH
2021_MES_410826_1
GE (AF)/CHD/T-40/2020-2021
Open Tender
Civil Works
Item Rate
240 days
GE (AF) Chandigarh
All as per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹79,000
Yes
25 Mar 2021
9 Jan 2021
8 Feb 2021
9 Jan 2021
6 Feb 2021
23 Jan 2021
Amount
Taking down wooden/steel/aluminium chowkhats or frames with shutters (without taking off shutters from the frame), of any description, not exceeding 1.50Sqm each, complete all as specified and directed.
Taking down wooden/steel/aluminium chowkhats or frames with shutters (without taking off shutters from the frame), of any description, exceeding 1.50 Sqm but not exceeding 4.00Sqm each, complete all as specified and directed.
S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S&F, anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-Charge.
S&F, anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-Charge.
S&F 125mm in size aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F 150mm in size aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F aluminium die cast boby, door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F brass Mortice lock 4 levers, vertical type, size 100 mm, complete all as specified and directed by Engineer-in-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed by Engineer-in-Charge.
M&L for false ceiling at heights of 600mm x600mm x16mm minral fiber ceoling tiles of type classic lite RH-99 fine texture of armstrong/ E-board 6mm thick or equivalent in 'Saint govind' laid on exposed grid systems. The frame work comprising of main runner spaced at 1200mm maximum (centre to centre),hangers (GI wire 4.0mm dia) to be fixed by approved roof plug level adjusters and screws etc. The last hanger at the end of each main runner shoul not greater than 450mm from the adjacent wall, flushing fitting 1200mm long cross trees (with double sticthing) to be interlocked between main runner at 600mm shall be 'T' shape section with single rotary stitching made of GS sheet and of size 15mm x32mm and 3000mm long, cross runner shall be 'T' shaped with double rotary stitching made of GS sheet and of size of 19mm x 19mm and 3000mm long, colour white, centre to from 1200mm x 600mm modules, cut cross tees longer than 600mm to be supported independently, 600mm x 600mm modules to be formed by fitting 600mm long flush fitting cross tees centrally betweeen the 1200mm cross tees. perimeter trim to be wall angle secured to wall at 450mm maximum (centre to centre) including PVC clips to hold the ceiling tiles, complete all as specified and directed.
Supply and fixing, 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing, solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, complete all as specified and directed by Engineer-in-Charge.
Supply and fxing, venation blind roller type (horizontally rolled) including all fittings, complete all as specified and directed.
Disconnecting existing tanks of capacity exceeding 250ltrs but n. exceeding 500ltrs, draining out of water, setting a side( or lowering if required) for repair/cleaning and removing accumulated sluge/dirt scales from tank bottom, side and from mouths of circulating pipes of service tanks located on roof of building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enemel paint on black ground "Cleaned on (date)" height of words100mm, and hoisting if required, refixing and reconnecting in position after cleaning, complete all as specified and directed by Engineer-in-Charge.
Supply and fix, ball valve high pressure of PTMT with epoxy coated aluminium rod and heigh density plastic ball, ISI marked screwed & suitable for iron pipe 15 mm dia bore and minimum weight 210 gms as in repair , complete all as specified and as directed
Dismantling brick tiles or terracing tiles single layer in roofs pointed in cement mortar stacking serviceable tiles to re-use and removal off rubbish out side MoD land complete all as specified and directed.
Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface, and removal out side the MoD land complete all as specified and directed.
Demolition of unreinforced cement concrete in any description and in any position not other wise specifically provided for, complete all as specified and directed.
Roughening of surfaces of old concrete slab by wiring brushing sweeping, cleaning and washing down to removal all loose dust etc. brushing neat neat cement slurry @ 3.00 kg/Sqm on roof surfaces, complete all as specified.
M&L plain cement concrete (1:2:4) type B-0(using 12.5mm graded crushed stone aggregates) as in roof kerb,benching and like complete all as specified and directed.
M&L 15mm thick cement plaster on roof or wall surfafes in cement mortar (1:4) mixed with WPC as per manufacturer's instruction @ 3% by weight of of cement on concrete surfaces,finished even and fair without using extra cement, after applying neat cement slurry @ 3Kg/Sqm, including wire brushing sweeping, cleaning, washing down to remove all loose dust etc. and preparing roof surfaces, complete all as specified and directed. Note:- WPC will be measured and paid separately.
M&L for water proofing treatment of roof consisting as under:- (a) Applying a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 Ltr/ Sqm including preparation of roof surfaces. (b) A layer of 3mm thick APP polymer mambrane of weight not less than3.67Kg/ Sqm, reinforced with polyster non wove fabric (wt. not less than 160 Gms/Sqm) duly sealed at over laps(100mm side lap and 150mm end over lap) and joint with LPG flame by torch aplication) all as per manufacturer's instruction complete all as specified and directed.
All as per Srl no. 24 here-in-before but on vertical surfaces, over primer @ of 0.30 Kg/Sqm complete all as specified and directed.
M&L cutting out cracks to V-section in existing RCC roofs or tarracing, cleaning out, wetting ,grouting with cement and sand slurry 1:3, complete all as specified and directed.
M&L for 40mm thick brick tiles laid on 15mm thick cement mortar screed bedding in cement mortar (1:6) and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on tiles are bedded in cement mortar (1:6) or lime mortar (1:3), 15mm thick, complete all as specified and directed.
All as per item No-27 here-in-before but retrived from dismantling.
M&L for cutting grooves in brick walls 75mm wide and 65mm deep for inserting APP membrane and shaping horizontal face of groove with cement mortar (1:3), removal the rubbish off the permises upto a distance not exceeding 50 mtrs complete all as specified and directd.
Preparation of old surfaces of walls including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. rubbing down and stoping of surfaces using sand paper and applying two coat of oil bond destemper complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises out side MoD land, complete all as specified and directed.
M&L for non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc.laid over 15mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in wall tiles, skirting etc, including 10mm thick cement plaster in cement mortar(1:4),complete all as specified and directed.
Demolition of cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing the rubbish out side MoD land, complete all as specified and directed.
M&L for 150mm thick Cement concrete type B- 2, 1:2:4 (40mm graded aggregate), as on paving /flooring, complete all as specified and directed.
Demolition of cement Concrete (reinforced) any description and in any position not otherwise specifically provided for and removing the rubbish out side MoD land, complete all as specified and directed.
M&L for PCC (1:2:4)type B-0, using 12.5mm graded stone aggregates, as in padding concrete to sunken floor. Coving /gola to junction of the floor and virtical walls including chamfering on edges, complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories.
S&F 110mm PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to wall with suitable size of mild steel clamp and screw, including making good mouth of rain water pipe in cement mortar 1:3 or PCC 1:2:4 complete all as specified and directed.
S&F 110mm PVC (SWR) bends any radius, complete all as specified and directed.
S&F Mild steel work as in bands, straps, supports/ stays and clamps for rain water pipes and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings and removing from site, complete all as specified and directed
S&F for pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
Dismantling framed timber scantlings of cross area exc 40 sq. cm and over in section, in any position, complete all as directed.
S&F Fe 410-W(Gde-E-250)Quality -rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, complete all as specified and directed.
M&L for preparation of new surfaces of iron/steel, over 10cm in width or girth, and applying two coat of synthetic enamel paint over a coat of redoxide primer not otherwise described, complete all as speified and directed.
Demolition of brick work built in cement mortar, including all quoins, arches, pillars, etc, complete all as directed.
S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; as gates for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, et and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
M&L for Cutting out bricks, forming toothing for, and bonding new into old work including value of new mat- erials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only), complete all as directed.
M&L for brickwork with subclass ‘B’ bricks(old size bricks), straight or curved on plan exc 6m mean radius built in cement mortar 1:4, complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks(old size bricks), straight or curved on plan exc 6m mean radius built in cement mortar 1:4, but except bricks, complete all as specified and directed.
M&L for Cement concrete type B-2, 1:2:4 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Taking down cement plaster in any description or in any position, including raking out joints, hacking for key, scrubbing down with water, etc, complete all as directed.
M&L complete removal to existing treatment on plaster/unplaster surfaces of wall and applying two coats of oil bond distemper including chalk whitening prepatory to distempering, complete all as specified and directed.
M&L complete removal to existing treatment on plaster/unplaster surfaces of ceiling and applying two coats of oil bond distemper, complete all as specified and directed.
M&L complete removal to existing treatment on plaster/unplaster surfaces of wall and applying two coats of first quality weather proof exterior acrylic emulsion paint over a coat of primer, complete all as specified and directed. Note: Primer and paint should be same manufacturer.
M&L for Rendering 15mm thick in cement mortar(1:4) on brick or concrete surfaces of wall finished even and fair without using extra cement, complete all as specified and directed.
M&L for Rendering 10mm thick in cement mortar(1:3) on brick or concrete surfaces of ceiling finished even and fair without using extra cement, complete all as specified and directed.
M&L for Rendering 15mm thick in cement mortar(1:6) on brick or concrete surfaces of ceiling finished even and smooth without using extra cement, complete all as specified and directed.
M&L preparation of new plaster/unplaster surfaces of wall and applying two coats of first quality weather proof exterior acrylic emulsion paint over a coat of primer, complete all as specified and directed. Note: Primer and paint should be same manufacturer.
Taking down defective main switches , electric meters, distribution board iron clad or sheet metal of any size and capacity including wooden board & MCBs etc, complete all as specified and directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.
M & L for point wiring complete with single core multi stranded Copper conductor cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including PVC conduit of size 20 mm dia or higher including Tee, junction, bends etc concealed in wall/fixed on ceiling and including M.S modular boxes of suitable size for housing modular switches, sockets etc including 1.5 sqmm. green PVC insulated wire for earth continuity complete. complete all as specified and directed by Engineer-in-Charge.
One light/fan point controlled by one way switch
One three pin 5 amp socket outlet multipurpose on independent board
One three pin 5 Amp switch socket cum on same board
All as per item No 64 above but with 2.5 sqmm cable insulated for 3 pin 15 amp multipurpose outlet including 1.5 sqmm PVC insulated copper wire for earth continuity on independent board complete.
Supply and fixing switch piano type, flush type, single pole, one way, 16 Amps, all as specified and directed.
Supply and fix, socket outlet, flush type, multi purpose 3 pin, 6 Amps & 16 Amps, 230 volts, all as specified and directed
Supply and fixing switch piano flush type, single pole, one way, 6Amps, all as specified.
Supply and fixing socket outlet flush type 2/3 pins 5 Amps multipurpose, all as specified and directed.
Supply and fix ceiling fan regulators step type electronic for 1200/1400 mm sweep ceiling fan, Make Usha/Orient/Khaitan/crompton and connecting up complete with provision of PVC flexible cable size 23/.0076 twin core copper conductor all required, all as specified.
Taking down fan, Sealing cable end, dismantling blades and removing fan and blades to store and M&L for painting of ceiling fans complete in situ with sysnthetic enamel paint buy spraying including filling cavities with filler , one coat after cleaning all dust etc
Disconnecting and taking down the complete exhaust fan of 450 mm sweep from the existing location and carry out rewinding by dismantling from frame with and including super enameled copper wire of suitable gauge of any make including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, greasing, lubricating, replacement of missing / worn out nuts, bolts & washers, split pins etc. and testing, complete all as specified and directed by Engineer – in - Charge for the following size: Make : Wire : Devi Dayal / HTP Ltd Bombay / Victor Varnish: MODI/CHINAR/ LOTUS
Supply and fixing in replacment of louver shutter suitable for exhaust fan of size 450 MM sweep, complete all as specified and directed by Engineer-in-Charge.
S & F sheet metal enclosure single pole and neutral with a two pin & earth plug and socket etc complete with on Double pole & earth MCB 20 Amps, 'B' curve, 240 volts 10 KA all as specified and directed.
Supply and fixing, in replacement of MCB SP 240 Volts 6 Amps to 32 Amps complete all as specified and directed by Engineer-in Charge.
Supply and fixing, in replacement of DB sheet metal enclosure double door for MCBs, company made, SPN 240 Volts 8 ways with IP 42 protection complete all as specified and directed by Engineer-in Charge.
S&F Isolator SPN 40 Amp 240 volts, 10KA, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of LED environmental friendly new generation, aesthetically designed , ultra modern recess mounting luminarie with high brightness SMD LEDs as light source suitable for Armstrong/Grid ceiling 42 W complete with all accessories . Make Havells Model No - PLUTONEO2x2PLR42WLED840S/Bajaj/Phillips/Wipro/ CG
Material & labour, earthing complete with galvanize steel earth plate electrode 60 cms x 60 cms x6.00mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate not less than 1.5 metre below normal ground level earth plate surrounded by 15 cm thick and packed alternate layers of charcoal dust and common salt, earth lead GI wire 4mm by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron or steel pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade (ISI marked ) with funnel and wire mesh ,including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No, 5 of MES Sch Part-1 (2009), complete all as specified.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 25 x 4 mm galvanised iron strip.
S&F wiring for circuit/Sub main wiring along with earth wire with two single core 2x 4 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper FRLS conductor in and including PVC concealed conduit 20 mm dia or higher ISI marked including one run of continuous PVC insulated FRLS multi stranded copper cable of size 1x2.5 Sqmm earth wire for earth continuity conductor complete all as specified.
Taking down carefully submain wiring including service connection complete with PVC conduit & GI wire any size and making good distrubed surfaces.
Note:- Amount of credit of Rs. 63270.00 for retrieved materials is mentioned in Schedule of Credit Page No 128 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Tejpal Singh and Co.
B N FRIENDS AND CO
SS BUILDERS
VRIDHI ENTERPRISES
shree balaji builders
SYNDICATE BUILDERS
MOHAMMAD RASHID
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .