Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.4 LAccepted-AOC | 1 | Accepted-AOC Accepted | |
| 2 | Rejected-Technical | - | Rejected-Technical Pls refer Uploaded Evaluation Report | |
| 3 | Rejected-Technical | - | Rejected-Technical Pls refer Uploaded Evaluation Report |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
22 Oct 2024, 12:00 pmClosed
City Engineer
MBMC Head Office
Empanelment of agency for Demolition of Existing structure within corporation Limits of Mira Bhayandar Municipal Corporation.
2024_MBMC_1113726_1
MBMC/PWD/Tender/94/24-25
Open Tender
Consultancy
Item Rate
365 days
MBMC
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,180
₹2 L
21 Mar 2025
11 Oct 2024
23 Oct 2024
11 Oct 2024
22 Oct 2024
11 Oct 2024
Amount
Description
Item no. 1 Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc SSR 46.09 /296
Item no. 2 Dismantling brick masonry in Mud and stacking the materials as directed with all leads,lifts etc. complete SSR 46.08 / 296
Item no. 3 Dismantling stone masonry in Mud including stacking the materials as directed with all leads, lifts etc. complete SSR 46.10 / 296
Item no. 4 Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. SSR 46.11 / 296
Item no. 5 Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. SSR 46.12 / 297
Item no. 6 Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. SSR 46.13 / 298
Item no. 7 Removing brick bat coba including stacking the spoils as directed with all leads,lifts etc, complete. SSR 46.14 / 299
Item no. 8 Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. SSR 46.29 / 297
9Item no. 8 Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. SSR 46.15 / 296
Item no. 10 Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. SSR 46.16 / 297
Item no. 11 Removing wooden or A.C. partition including frame work and stack-ing the materials as with all leads, lifts etc. complete. SSR 46.17 / 297
Item no. 12 Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete SSR 46.19 / 298
Item no. 13 Dismantling wooden floor including beams and joists, stacking the materials as directed with all leads, lifts etc. complete. SSR 46.21 / 297
Item no. 14 Removing mud plaster including disposing of the spoils as directed with all leads, lifts etc, complete SSR 46.23 / 297
Item no. 15 Removing earthen, stonewate pipe and stacking them as directed with all leads, lifts etc. complete. SSR 46.27 / 297
Item no. 16 Removing cast iron or wrought iron or A.C. pipe and stacking them as directed with all leads, lifts etc. complete SSR 46.28 / 297
Item no. 17 Removing Np-2 and Np-3 class pipes including stacking at road side as directed by the Engineer in charge. Upto 900mm dia. etc complete. SSR 46.30 / 297
Item no. 18 Removing Np-2 and Np-3 class pipes including stacking at road side as directed by the Engineer in charge. Upto 900mm dia and above. etc complete. SSR 46.31 / 297
Item no. 19 Removing single country tiled roof with battens and stacking the materials as directed with all leads and lifts etc. complete. SSR 46.32 / 297
Item no. 20 Removing battens from roof and stacking them as directed with all leads and lifts etc. complete. SSR 46.33 / 297
Item no. 21 Removing matting from roof and stacking as directed with all leads and lifts etc. complete. SSR 46.34 / 297
Item no. 22 Removing purlins from roof including stacking as directed with all leads , lifts etc. complete SSR 46.35 / 298
Item no. 23 Removing rafters from roof including the materials as directed with all leads , lifts etc. complete. SSR 46.36 / 298
Item no. 24 Removing cloth partition with frame work and stacking the materials as directed with all leads , lifts etc. complete SSR 46.37 / 298
Item no. 25 Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete. SSR 46.38 / 298
Item no. 26 Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete SSR 46.40 / 298
Item no. 27 Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. SSR 46.41 / 298
Item no. 28 Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. SSR 46.42 / 299
Item no. 29 Removing Manglore tiled roof and ridge tiles with battens, ridge and barge boards, eaves 8 A boards etc and sacking the materials as directed with all leads and lifts complete. Including removing wood work below etc. complete SSR 46.43 / 299
Item no. 30 Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately SSR 7.25 / 72
Item no. 31 Removing wire fencing with iron/ C.C. fencing post and stacking the materials as directed with all leads, lifts etc. complete. SSR 46.25/ 297
Item no. 32 Dismantling of concrete pedestal up to required height including cutting reinforcement by using of concrete saw, complete including all fixing arrangements of the machines, water for cooling, diamond saw, other accessories, safety of workers and removal and disposal of debris as per instruction of site in- charge etc complte SSR 19.37 / 150
Item no. 33 Dismantling of concrete pedestal up to required height using electrical breakers including cutting reinforcement by gas cutters, other accessories, safety of workers and removal and disposal of debris as per instruction of site in- charge SSR 19.38 / 150
Item no. 34 Removing double country tiled roof with ridge and with battens and stacking the materials as directed with all leads and lifts, complete including removing wood work below etc. complete SSR 46.01 / 296
Item no. 35 Removing planking from roof or ceiling and stacking them sa directed with all leads and lifts etc. complete SSR 46.02 / 296
Item no. 36 Removing Queen Post truss from roof and stacking the materials as directed with all leads and lifts etc. completse SSR 46.03 / 296
Item no. 37 Removing King Post truss from roof and stacking the materials as directed with all leads and lifts etc. complets SSR 46.04 / 296
Item no. 38 Removing other type truss below 5 metres span from roof and stacking the materials as directed with all leads and lifts etc. complets SSR 46.26 / 296
Item no. 39 Removing iron pipe raling having wooden R.C.C. or C.C. or iron post and stacking the materials as directed etc. complete SSR 46.26 / 297
Item no. 40 Removing cloth ceiling including frame work and stacking the materials as ditected with all leads, lifts etc. complete SSR 46.07 / 297
Item no. 41 Removing the tiles, battens and dungry cloth purlins, rafters and ridges etc. from roof, sorting out the serviceable and unserviceable materials and stacking the same as and where directed in the compound, scaffolding etc. complete. SSR 38.25/ 235
Item no. 42 Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding etc. complete. SSR 38.26/ 235
Item no. 43 Removing and lowering the roof truss carefully without damaging the members and stacking as and where directed in the compound including scaffolding etc. complete. SSR 38.27/ 236
Item no. 44 Removing R.S. girders of any size and span lowering the same and stacking neatly wherever directed in the compound scaffolding etc. complete. SSR 38.28/ 236
Item no. 45 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means SSR 21.02/ 153
Item no. 46 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means SSR 21.04/ 153
ITEM NO. 47 TRANSPORTING OF EXCAVATED MATERIALS lead 20.00 k.m.
Item no. 48 Lowering down the debris obtained from breaking and removing the cement plaster /burnt brick masonry of the first floor by any means without causing dust nuisance and damage to structure, stacking the same as and where directed including cleaning the site complete. SSR 46.59 / 301
Item no. 49 Providing Heavy Duty Fibre Glass Reinforced Plastic Temporary Barricade of 1.75 m hight, with base width of 430 mm as a provision to accept water ballasting of 101 Itrs-110 Ltrs approx. and arrangement for traffic diversion such as traffic signals during construction at site, for day and night as per requirement. The raw material shall be UV stabilized Linear Low Density Polyethylene and should meet the requirements stipulated in standard IS: 10146-1982, IS:10141-1982 and should also comply to FDA:CFR Title 21.177.1520. Olefin Polymers , with specific FRP Grade 300-104 reinforced during moulding process to the permissible extent for improved impact strength. Qualification Criteria: For qualifying the sample , few tests shall be performed at Government Lab OR NABL Accredited Lab on Site Safety Fence sample, failure or deviations in test results of sample shall be disqualified.The tests and qualifying results are as under, (a) tensile strength at yield by ASTM D 638 =20.93 mPA, (b) Elongation at break ASTM D 638 = 121.66 mPA (c) Flexural Modulus ASTM D 790 = 633.76 mPA (d) Izod Impact Strenth (Notched) ASTM D 256 = 4.41Kilogram/ One Square Metre (e) Izod Impact Strenth (Un Notched) ASTM D 256 = 67.04Kilogram/ One Square Metre (f) Drop Impact strength 25KilogramLoad from 1 m, 2 m & 5m height the weight of empty single Rotomoulded Plastic Barricade without water ballasting shall be 34 Kilograms approx. & total weight after water allasting shall be 135 Kilograms -140 Kilograms +/- 5 Kilograms (tolarance)The main Barricade body of hight 1750 mm approx is connected with the Extension body through 4 set of nut bolt washers .extenstion body through 4 set of nut bolt washers. Extension body is designed with 9 Nos kiss offs on rear side; the dimension of Extension body are 1500 mm (length),70 mm (width),250 mm (effetive height after fixing ) & dimension of its male collarare 1420 mm (length),25 mm (width),30 mm approx ( height), it is inserted in U groove provisioned on top of main body Barricade Model for interlconnecting.the minimum thickness of all over surface of plastic barricaed shall be 5 mm +/- 20%.the rear bottam shall have to provision to fix two brackets at both end in corner for anchoring purpose .each rear bracket is constructed through rod of Dia.60 mm with curvature welded with MS strip of 3 mm thick ,50 mm width and 90 mm length at its top and base ,effective bracket shall be 410 mm approx. the anchoring SSR 50.46 / 342
a) For 725 mm height (LType Jersey Barrier ) ,Empty Weight:6.67 Kilogram/Rgm,Weight Full : 35.89Kilogram/ Rgm approx. (After Water / Sand Filling)
b) For 750 mm height (With Interlocking provison - For Traffic Delineation Applications ) , Empty Weight:9.04 Kilogram/ Rgm,Weight Full : 57.14Kilogram/ Rgm approx. (After Water / Sand Filling)
c) For 750 mm height ( Jersey Barrier Model with unique Interlocking Provision) ,Empty Weight:9.0 Kilogram/ Rgm,Weight Full : 55.00Kilogram/ Rgm approx. (After Water / Sand Filling)
d) Site Safety Fence (1.75 Mtrs(H)) (Efficient Substitution to sheet Metal Barricade) ,Empty Weight 16.57: Kilogram/ Rgm,Weight Full : 74.29 Kilogram/ Rgm approx. (After Water / Sand Filling)
e) Site Safety Fence (2.00 Mtrs(H)) (Efficient Substitution to sheet Metal Barricade) ,Empty Weight : 17.00 Kilogram/ Rgm,Weight Full : 70.00 Kilogram/ Rgm approx. (After Water / Sand Filling)
Item no. 50 Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete. SSR 46.06 / 296
Item no. 51 Dozer D-8 H ( Heavy ) Capacity 270 HP SSR Page No. 547 Sr. No. 1 A -1
Item no. 52 Dozer D 80 A 12 (Medium ) Capacity 180 HP SSR Page No. 547 Sr. No. 1 A -2
Item no. 53 Shantui Dozer D-3 B (Medium ) Capacity 65 HP SSR Page No. 547 Sr. No. 1 A -3
Item no. 54 Shantui Dozer SD13 Capacity 130 HP SSR Page No. 547 Sr. No. 1 A -4
Item no. 55 Shantui Dozer SD16 Capacity 180 HP SSR Page No. 547 Sr. No. 1 A -5
Item no. 56 Hydraulic Excavator ( Tata Hitachi EX 350 ) Capacity 1.7 Cum SSR Page No. 547 Sr. No. 1 A -5
Item no. 57 Hydraulic Excavator ( Tata Hitachi EX 350 ) Capacity 1.7 Cum SSR Page No. 547 Sr. No. 1 A -5
Item no. 58 Loader 1.00 cum Bucket capacity Capacity 1.00 Cum SSR Page No. 547 Sr. No. 1 A -19
Item no. 59 Loader 1.00 cum Bucket capacity Capacity 1.00 Cum SSR Page No. 547 Sr. No. 1 A -20
Item no. 60 Loader 2.0 cum bucket capacity Capacity 2.00 Cum SSR Page No. 547 Sr. No. 1 A -21
Item no. 61 Loader 2.0 cum bucket capacity Capacity 2.00 Cum SSR Page No. 547 Sr. No. 1 A -22
Item no. 62 Motor grader 3.35 mtr Blade Capacity 145 Hp SSR Page No. 547 Sr. No. 1 A -23
Item no. 63 Eicher Tipper 8.5 Cum Capacity 8.5 Cum SSR Page No. 547 Sr. No. 1 A -36
Item no. 64 Eicher Tipper 8.5 Cum Capacity 8.5 Cum SSR Page No. 547 Sr. No. 1 A -37
Item no. 65 Tipper -6 cum Capacity 6 Cum SSR Page No. 547 Sr. No. 1 A -40
Item no. 66 Tipper -6 cum (20 Km/Hr) Capacity 6 Cum SSR Page No. 547 Sr. No. 1 A -41
Item no. 67 Tipper TATA LPK 2518 BS III Capacity 25 MT SSR Page No. 547 Sr. No. 1 A -44
Item no. 68 Tipper TATA LPK 2518 BS III Capacity 25 MT SSR Page No. 547 Sr. No. 1 A -45
(ELECTRICAL WORK)
Item no. 69 Credit for Dismantled Material -PVC armoured/unarmoured cables and wires (Aluminium) CSR 20-1-1
Item no. 70 Credit for Dismantled Material - PVC armoured/unarmoured cables and wires (Copper CSR 20-1-2
Item no. 71 Credit for Dismantled Material -Aluminum materials CSR 20-1-3
Item no. 72 Credit for Dismantled Material -H.G. / M.S. / G.I. Materials / Poles etc. CSR 20-1-4
Item no. 73 Credit for Dismantled Material - Copper / Brass materials CSR 20-1-5
Item no. 74 Credit for Dismantled Material -Wooden materials CSR 20-1-6
Item no. 75 Credit for Dismantled Material - PVC pipes/materials CSR 20-1-7
Item no. 76 Credit for Dismantled Material -Paper cartoons/boxes. CSR 20-1-8
Item no. 77 Credit for Dismantled Material -I.C. / M.C. switches / D.P. / D.B./ T.P. / feeder pillar etc. CSR 20-1-9
Item no. 78 Credit for Dismantled Material - Meters (Ammeter / Voltmeter / Energy meter / All types of PCB etc..) CSR 20-1-10
Item no. 79 Credit for Dismantled Material -O.C.B. (without oil)/ A.C.B / V.C.B CSR 20-1-11
Item no. 80 Credit for Dismantled Material - Ceiling/cabin/bracket/pedestal/table fan. CSR 20-1-12
Item no. 81 Credit for Dismantled Material -Exhaust Fan 9" Sweep CSR 20-1-13
Item no. 82 Credit for Dismantled Material -Exhaust Fan 12" Sweep CSR 20-1-14
Item no. 83 Credit for Dismantled Material -Exhaust Fan 15" Sweep CSR 20-1-15
Item no. 84 Credit for Dismantled Material -Exhaust Fan 18" Sweep CSR 20-1-16
Item no. 85 Credit for Dismantled Material -Exhaust Fan 24" Sweep CSR 20-1-17
Item no. 86 Credit for Dismantled Material -Air circulators CSR 20-1-18
Item no. 87 Credit for Dismantled Material -Fluorescent fittings CSR 20-1-19
Item no. 88 Credit for Dismantled Material -Street/flood light fittings. CSR 20-1-20
Item no. 89 Credit for Dismantled Material -Geysers CSR 20-1-21
Item no. 90 Credit for Dismantled Material - Accessories such as tube starter / bell / holder / ceiling rose / MCB / MCCB / Contactor / PT etc. CSR 20-1-22
Item no. 91 Credit for Dismantled Material - Chokes / condenser / small coils / motor starter etc. CSR 20-1-23
Item no. 92 Credit for Dismantled Material -Lift ropes / belts CSR 20-1-24
Item no. 93 Credit for Dismantled Material -Hot water boilers CSR 20-1-25
Item no. 94 Credit for Dismantled Material -Electric motors CSR 20-1-26
Item no. 95 Credit for Dismantled Material -Water pump sets. CSR 20-1-27
Item no. 96 Credit for Dismantled Material -A.C compressors / Inverter Compressor CSR 20-1-28
Item no. 97 Credit for Dismantled Material - Window air conditioning unit CSR 20-1-29
Item no. 98 Credit for Dismantled Material - Outdoor unit of split / Cassette air conditioner. CSR 20-1-30
Item no. 99 Credit for Dismantled Material -Indoor unit of split / Cassette air conditioner. CSR 20-1-31
Item no. 100 Credit for Dismantled Material -Instant type water cooler CSR 20-1-32
Item no. 101 Credit for Dismantled Material -Storage type Water cooler CSR 20-1-33
Item no. 102 Credit for Dismantled Material -Refrigerator up to 165 Litre CSR 20-1-34
Item no. 103 Credit for Dismantled Material -Refrigerator above 165 Litre CSR 20-1-35
Item no. 104 Credit for Dismantled Material -Air coolers without fan. CSR 20-1-36
Item no. 105 Credit for Dismantled Material -Air coolers with fan. CSR 20-1-37
Item no. 106 Credit for Dismantled Material -Transformer oil / OCB Oil CSR 20-1-38
Item no. 107 Credit for Dismantled Material -Diesel Generating set CSR 20-1-39
Item no. 108 Credit for Dismantled Material - Transformer (Copper Winding CSR 20-1-40
Item no. 109 Credit for Dismantled Material - Transformer (Alluminium Winding) CSR 20-1-41
Item no. 110 Credit for Dismantled Material -Telephone exchange (EPABX) CSR 20-1-42
Item no. 111 Credit for Dismantled Material -Telephone instrument CSR 20-1-43
Item no. 112 Credit for Dismantled Material -Water Purifier CSR 20-1-44
Item no. 113 Credit for Dismantled Material -Inverter / UPS CSR 20-1-45
Item no. 114 Credit for Dismantled Material - Voltage Stabilizer CSR 20-1-46
Item no. 115 Credit for Dismantled Material -Amplifier CSR 20-1-47
Item no. 116 Credit for Dismantled Material - Mikes CSR 20-1-48
Item no. 117 Credit for Dismantled Material -Storage type water purifier CSR 20-1-49
Item no. 118 Credit for Dismantled Material - Tubular / SMF Battery CSR 20-1-50
Item no. 119 Credit for Dismantled Material -All types of SS material CSR 20-1-51
Item no. 120 Credit for Dismantled Material -All types of LED Tube and Fixtures CSR 20-1-52
Item no. 121 Credit for Dismantled Material -FPC Solar Hot Water System 100 LPD CSR 20-1-53
Item no. 122 Credit for Dismantled Material -FPC Solar Hot Water System 200 LPD CSR 20-1-54
Item no. 123 Credit for Dismantled Material -FPC Solar Hot Water System 300 LPD CSR 20-1-55
Item no. 124 Credit for Dismantled Material -FPC Solar Hot Water System 500 LPD CSR 20-1-56
Item no. 125 Credit for Dismantled Material -ETC Solar Hot Water System 100 LPD CSR 20-1-57
Item no. 126 Credit for Dismantled Material -ETC Solar Hot Water System 200 LPD CSR 20-1-58
Item no. 127 Credit for Dismantled Material -ETC Solar Hot Water System 250 LPD CSR 20-1-59
Item no. 128 Credit for Dismantled Material -ETC Solar Hot Water System 300 LPD CSR 20-1-60
Item no. 129 Credit for Dismantled Material -ETC Solar Hot Water System 500 LPD CSR 20-1-61
Item no. 130 Dismantling the existing 8 to 12 Passenger lift of all types travelling G+1 floors (2 Landings/2Stops) having with auto/manual operated doors for lift car & all landings with door frames, guide rails, controller, wiring buffers, Lift Machine, ropes complete with all allied accessories of Lift and making the site clear in all respect complete with refilling the holes with cement mortar & making the site as original this job includes transportation of the dismantled material up to division/section store and handing over to the section engineer/store keeper in charge complete. CSR 17-2-2
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .