Loading…
Loading…
Tender Value
₹15.3 L
EMD Value
₹16,000
Closing Date
25 Sept 2026, 6:10 pmClosed
Executive Engineer, Sabarkantha Irrigation Division, Himatnagar
Renovation of executive engineer bunglow at lal colony, himatnagar for shifting office of himatnagar irrigation sub dn no. 1 himatnagar.
344078
Tender Notice No 09 of 2026-27
Open
Civil Works
Works
Sabarkantha
7 documents required · 6 mandatory · 1 optional
₹900
Executive Engineer Sabarkantha Irrigation Division Himatnagar
₹16,000
11 Sept 2026
11 Sept 2026
11 Sept 2026
25 Sept 2026
11 Sept 2026
BILL OF QUANTITIES
Item Description of Item
Quantity Rate In figures Unit Amount
No. (with brief specification and reference to book of specifications)
1 Demolition including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work 6.00 1081.83 CUM
2 Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. 26.00 49.18 Sqm.
3 Dismantling santtary fittings like wash basin . W.C. pan Indian and European type, flushing tank etc. including stacking the materials with all lead and lift. 5.00 413.49 Each
Removing and scraping of old deteriorated plaster of any thickness fromm wall / R.C.C member including stacking of serviceable material and disposal of unserviceable
from site of work with all lead and lift
Dismentling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats architraves, holdfasts and other attachment etc. complete and stacking them
within all lead and lift.(i) Not exceeding 3 Sq.M. in area.
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter
lead.(A) Loose or soft soil
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter
lead.(A) Loose or soft soiland disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation for depth from 3.0 m to 5.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter
lead.(A) Loose or soft soiland disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Extra for additional depth more than 5.0 m for excavation for foundation including sorting out and stacking of useful materials and disposing of the excavated stuff
upto 50 m lead.(A) Loose or soft soil
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of
10 formwork in (A) Foundation and Plinth : 150 thk. M10 PCC Below Foundation 1.00 3095.25 CUM
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (C)
Slabs,landing,shelves,Balconies, Lintels, Beams, Girders and Cantilever upto floor two level. 150 Thk M25 RCC Slab
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement :
5 -fine sand)(B) Conventional
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cement :
13 5 -fine sand)(B) Conventional 7.00 4526.76 CUM
Extra for brick work in superstructure above plinth level upto floor two level (B) Conventional
Providing and placing in position reinforcement bars including cutting, bending welding, joints where necessary, hooking etc.complete as per drawing for all lead and
14 lifts. 7.00 7194.00 Qtl
Providing 20 mm thick double coat mala cement plaster on interior brick / concrete work for plastering comprising of base coat of 12 mm thick cement plaster in
15 cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including 663.00 284.33 SQM
scaffolding curing etc. complete.
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing
16 flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the 63.00 1311.18 SQM
surface etc. complete for light shade
Providing and laying granite slab 18mm thick in Window-Door seal Frame Etc laid on 10mm thick cement mortar 1:4 ( 1 Cement : 4 coarse Snd ) with nessary adhesive
17 material and finished with flush pointingin white or colour cement, Including eubbing & Polishing comp. Material and procedure of application shall be approved by 64.00 1994.20 SQM
Providing and laying broken chine mosaic flooring including heavy duty water proofing for terrace using 12 mm to 20 mm broken pieces of glazed tiles to be
laid over cement mortar 1:3 admixed with " DR FIXIT LW + " or equivalent after laying 3 coats of " DR FIXIT NEW COAT " or equvalent to plain or slope and to
be tempered to bring mortar creme out upto surface using white cement including rounding off junctions and extending them upto 15 cm along the wall,clearing
with water and oxalic acid etc. as directed
Item Description of Item
Quantity Rate In figures Unit Amount
No. (with brief specification and reference to book of specifications)
i) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement mixed with water proofing compound conforming to IS. 2645 over the RCC slab including
adjoining walls upto 300mm height.ii) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement :
coarse sand) mixed with water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) mixed with
water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of
19 walls and slabs.iii) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound 16.00 826.73 SQM
conforming to IS : 2645.iv) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) mixed with water proofing compound
conforming to IS : 2645 including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry
and making pattern of 300x300 mm square 3mm deep.v) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and
for final test.All above operations to be done in order:
Providing and fixing Alluminium Door with Frame Size 100 x 50 mm and 28 mm thick Alluminium depress panel Single or Double shutter.The Door And Frame insitu
along with embeded steel pieces for stiffening & also taking hinges & fintures.The whole Alluminium frame&single or double shutter is to be waterproof, weatherproof,
termite proof & resistance to mild acid/alkali.Rates are to be inclusive of S.S hinges with necessary screws & alluminum fixtures & fastenings & fartenersleeve.Colour
and Shade approved by Engineer-In-Charge.
Providing and fixing extruded aluminum window having extruded aluminum Colour Powder Coated section frame main outer size 127mm x 38.10mm x 1.35mm, @
Wt. 1.384 Kg/mt, horizontal Three track member size 122.20mm x 31.75mm x 1.10mm @ Wt. 1.205 Kg/mt, vertical member of size 122.20mm x 31.75mm x 1.50mm, @
Wt. 1.398 Kg/mt with sliding shutters of horizontal member size 40mm x 18mm x 1.29mm @ wt. of 0.456 Kg/mt, vertical member of size 40mm x 18mm x 1.29mm @ wt.
of 0.456 Kg/mt, fitted with 5 mm thick transparent bronze colour tinted float glass. One shutter will be provided with a mosquito net, made of high-quality rust-
resistant mesh and powder-coated aluminum frame. The window will include powder-coated aluminum fittings and fixtures, and transparent silicon sealant will be
used for fixing the glass to the frame as per details, etc., complete for the window.
Applying two coats of putty & two coats of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign matter and sand papered smooth.
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly
brushing the surface free from mortar droppings and other foreign matter and sand papered smooth.
Carring out plinth treatment to post construction / existing structure by spraying chemical solution for termite control treatment including labour and material
consistment with I.S.I specification. Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration Weight one percent is recommended i.e one litre
EC chemical emulsion with 19 liter give 1 % concrentration inclusive of one litre chemical emulsion appication at the rate of 5 Litre chemical / Sqm of surface is
recommended as per I.S
Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5 sq. mm & earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated
multi strand copper wires upto max length of 10 mt, in below type of pipe erected with 6A Tissino Type ISI marked flush type switch / bell push and accessories
erected on Metal / PVC/Wooden Box covered with 3 mm thick PC(Polycarbonate) /Acrylic/Laminated sheet. with necessary Lamp holder/ceiling rose / H.D.Connector
as directed. (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Providing & fixing PVC SWR Nahni Trap IS 14735 for Drain - 100 mm diameter with jali of the following nominal diameter of self cleansing design with C.I. screwed
down or hinged grating including the cost of cutting and making good the walls . ( C ) 100 mm dia.
Providing and fixing wsh down water closet (European type, W.C. Pan) with integral P or S trap including jointing the trap with soil pipe in Cement Mortar 1:1 (1-
Cement : 1-fine sand) (Seal and cover to be measured and paid for separately)(A) vitreous China Pattern :(i) in white colour.
Providing and fixing 12.5 Litres high level C..I. flushing cistern with A pair of C.I. or Mild steel brackets, womplete with fittings such as syplionic arrangement, 15mm
28 nominal size brass ball valve with polythene float, lever G.I. China (60 cm. ) and pull union and couplings for connections with inlet, outlet and overflow pipes etc. 3.00 1580.28 Each
including cutting holes in walls and making good the same (overflow pipe to be measured and paid fo separately )
29 Providing and Fixing 15mm dia C.P. 2 Way Bibcock of approved make with C.P. wall flange with 15mm C.P. connector pipes with Health Faucet fixing complete etc. 7.00 2146.25 Each
30 Providing and fixing M.I. fisher union for washbasin or sink. (B) 40mm dia. 4.00 88.65 Each
31 Providing and fixing Rubber plug for sink or wash basin 4.00 17.15 Each
Providing and fixing Washbasin with single hole for pillar tap with C.I. or M.S. brackets painted white including sutting holes, making good the same but excluding
32 fittings.(A) Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white colour, C.P. brass waste for washbasin or sink. (B) 40mm dia., Rubber plug, 4 1830.12 Each
Bottle trap with necessary couplings of approved quality, M.I. fisher union for washbasin or sink. (B) 40mm dia.
Item Description of Item
Quantity Rate In figures Unit Amount
No. (with brief specification and reference to book of specifications)
Providing and fixing 600mm x 450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C. sheet and fixing to wooden pluge with C.P. brass screws and
34 Providing and fixing C.P. brass towel rail complete with C.P. brass brackets fixed to wooden plugs with C.P. brass screws. (B) 600mm x 20 mm size. 4.00 616.42 Each
35 Providing and fixing pillar tap,capstan head, screw down high pressure with screws, shanks and back nuts. (ii) 20mm dia. 20.00 354.69 Each
36 Providing and fixing brass BALL Valve 25mm dia. 20.00 909.00 Each
Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
37 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints 50.00 72.65 Rmt
and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall
38 be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints 150.00 91.84 Rmt
and fixing the same with adhesive solvent, including cost of all materials.
Providing, laying and jointing in true line and level U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, &
fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on
wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with bricks having crushing strength not less than 35Kg./Cm2 in C.M.1:5
C.I. cover with frame (Light Duty) 600mm x 600 mm internal dimensions total weight of cover with frame to be not less than 38 Kg.(Wt. of cover 23 Kg.) and Wt. of
40 frame 15Kg.) ( R.C.C. top slab with 1:2:4 mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick 4.00 7180.44 Each
with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete. (iii) Inside dimensions 600mm x 850mm and
450mm deep for pipe lines with three or more inlets (more than 10 ton)
41 Extra over items 24.44 for every additional depth of 0.1M of part thereof beyond 450mm depth for Brick masonry chamber (iii) for 600mm x 850mm 4.00 325.59 Each
Providing & Fixing S.W. Gully trap with C I grating brick masanry chanber & water tight C I cover with fram 300mm X300mm size ( inside ) standard weight. (i)
Square mount trap (B) 150mm X 100mm size.
Providing erecting and fixing double coated Syntex/Super/Reno PVC (ISI) mark water tank of required capacity each with all necessary fittings & connection etc.
complete on terrace.
Rupees Fifteenm Lakhs Fourty Five thousand Fourty Five Hundred seventy Thirteen rupees and Ninty Six paise only
I / We / am/are willing to carry out the work at ________________________________% above/below percent (should be written in figure and words) of the estimated rates mentioned above. Amount of my/our tender Works out as under.
Estimated Amount Estimated Amount
put to tender Rs. _________ put to tender Rs. _________
Deduct_______% below Add_______% above
Net Rs._________ Net Rs._________
in words ___________ in words ___________
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills.
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as
per actual mix design the cost of difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Signature of Contractor
Deputy Executive Engineer Executive Engineer
Himatnagar Irrigation Sub Dn. No. 1 Sabarkantha Irrigation Division
Item Description of Item
Quantity Rate In figures Unit Amount
No. (with brief specification and reference to book of specifications)
Himatnagar Himatnagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
00 SBD_EERB 1009.pdf
Tender Notice 09 of 2026-27.pdf
BOQ .pdf
PA .pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .