Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 accepted | |
| 2 | L2₹56.9 L+₹8.6 L (17.9%)Rejected-AOC | L2 | Rejected-AOC Being L2 Rejected | |
| 3 | L3₹64.0 L+₹15.7 L (32.6%)Rejected-AOC 114 JYOTHI SHIKHAR BUILDING 8 DISTRICT CENTRE JANAKPURI NEW DELHI 110058 | NEW DELHI | WEST DELHI | DELHI | 110058 | L3 | Rejected-AOC Being L3 Rejected |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
24 Jan 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MANAGING DIRECTOR
KSDP LTD,KALAVOOR P.O,ALAPPZUHA
SUPPLY, INSTALLATION AND COMMISSIONING OF CLEAN ROOM PANEL WORKS USING PCGI PANELS AS PER GMP STANDARD FOR NON BETA LACTUM PROJECT
2021_ksdp_453454_3
KSDP/PRJ/NB/PCGI/09/21-22/123
Open Tender
Civil Works - Buildings
Item Rate
90 days
KSDP LTD, KALAVOOR P.O, ALAPPZUHA
AS PER TENDER DETAILS
12 documents required · 12 mandatory
₹2,950
₹50,000
19 Aug 2022
14 Jan 2022
25 Jan 2022
14 Jan 2022
24 Jan 2022
14 Jan 2022
14 Jan 2022 - 24 Jan 2022
120 days
CLEAN ROOM WALL PARTITIONS ( Powder Coated Galvanised Iron ) ( PCGI / PCGI)
Double skin Wall panels- 80 mm thick ( Suitable to accomodate return air risers ) 80mm thick double skin wall panels of skin thick 0.8 mm Sheet 0n both sides . PUF as infill material Density 40-42 Kg/Cu mtr with both side powder coating of thickness 60-70 microns including Bottom track & silicon sealent etc. as completed.
Double skin Wall panels- 50 mm Thick
50 mm thick double skin wall panels of skin thick 0.8mm Sheet 0n both sides . PUF as infill material Density 40-42 Kg/Cu mtr with both side powder coating of thickness 60-70 microns including Bottom track & silicon sealent etc.
Double skin panels for Column Cladding- 50 mm thick
50 mm thick double skin wall Clading panels of skin thick 0.8 mm Sheet. PUF as infill material Density 40-42 Kg/Cu mtr with both side powder coating of thickness 60-70 microns.
Double skin wall panels- 80 mm thick (PCGI/SS304) ( Suitable to accomodate return air risers ) 80 mm thick double skin wall panels of skin thick 0.8 mm Sheet one side other side SS304 , 0.8 mm thick Matt Finish. PUF as infill material Density 40-42 Kg/Cu mtr with powder coating of thickness 60-70 microns.
False Ceiling Panels (PCGI/PCGI)
50 mm thick double skin Non walkable Clean Room False ceiling panels with skin thickness of 0.8 mm
False Ceiling cut outs in existing erected and new panel
HVAC cutouts for filters , grills and risers (Dimensions: Maximum 790 X 790 mm )
Luminaires cutouts (Dimensions : Maximum 600 x 600 mm )
Double Glazed View panel as per following diamentions suitable for 80 and 50 mm thick wall panel
covings ( MOC Aluminium) supply and fixing in existing and new panel
floor to wall
wall to wall and wall to ceiling
EDGE Guard
corner pieces( 2 D AND 3D)
PVC Conduits - Size 25mmØ inside panel for existing and new panel
Electrical (power point , switch , magnehellic gauge ) cutouts (Dimensions upto : ( 300 X 300 mm ) in new panel
Electrical (power point , switch , magnehellic gauge ) cutouts (Dimensions upto : ( 300 X 300 mm ) in existing panels Iincluding drilling for conduit entry
GI PU Painted clean room Doors Doors suittable for 80 and 50 mm thick wall/panel mounted for following diamentions with frame , lock etc as complete
1000 to 1300 mm X 2100 MM with frame
Emergency exit Door - wall/panel mounted for following diamtions with frame , lock etc as complete
1000 to 1300 mm X 2100 MM with frame
supply and Application of food grade sealant in already erected panels
Dismantling of already erected PCGI wall panel/ceinlg panel of 80/50 mm thickness
Erection of PCGI wall including application sealant panel/ceiling panel of 80/50 mm thickness ( Accessories required for erection to be considered supply of panel is not in scope)
supply and fixing of view glass of size upto to 1200 x 1200 mm in panel
Removal of already erected GI PU painted Doors
refixing of available GI PU painted Doors (supply of door not in scope. bidder has to quote the rate for erection. materials/accessories required for erection also to be considered. )
supply and fixing of double glazed view glass in doors upto 400x 400 mm
supply and fixing of ss handle for exisitng doors
covering channel 0.8 mm thick GI powder coater C channel to intercoonet new panel with exisiing panel
return air riser suitable to inbulit in fabricated wall panel of thickness about 80 mm made out of 22 GI sheets suitable for fixing module and perforated grills
mak clean air systems pvt ltd
CREATIVE HEALTHTECH PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .