| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-AOC | L1 | Accepted-AOC TECHNO COMMERCIALLY ACCEPTED BID | |
| 2 | L2₹1.2 L+₹3,194.63 (2.67%)Rejected-Finance AT GURUDWARA SOUTH BALANDA TALCHER ANGUL ODISHA 759100 | ANUGUL | ODISHA | 759100 | L2 | Rejected-Finance AS PER TC RECOMMENDATION | |
| 3 | L3₹1.3 L+₹9,057.63 (7.57%)Rejected-Finance AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L3 | Rejected-Finance AS PER TC RECOMMENDATION | |
| 4 | L4₹1.3 L+₹11,789.73 (9.86%)Rejected-Finance AT PLOT 2388 8730 239 8731 2387 5729 INFRONT OF BSNL OFFICE GANDHI CHOWK BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L4 | Rejected-Finance AS PER TC RECOMMENDATION | |
| 5 | L5₹1.5 L+₹27,119.26 (22.7%)Rejected-Finance 14 11 ITI COLONY HIRAKUD SAMBALPUR | SAMBALPUR | ODISHA | 768001 | L5 | Rejected-Finance AS PER TC RECOMMENDATION |
Tender Value
₹2.7 L
EMD Value
₹3,400
Closing Date
7 Apr 2025, 5:00 pmClosed
SO E AND M
OFFICE OF SO E AND M BASUNDHARA AREA MCL
Power supply and internal wiring of security office near security barrack of Basundhara Area
2025_MCL_333256_1
MCL/GM/ BA/EM/e-Proc/2024-25/38 Date- 25/03/2025
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
BASUNDHARA AREA
AS PER NIT AND TC
4 documents required · 4 mandatory
₹3,400
Yes
6 May 2025
25 Mar 2025
8 Apr 2025
25 Mar 2025
7 Apr 2025
26 Mar 2025
25 Mar 2025 - 31 Mar 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(GROUP "B" )
Wiring for circuit/ submain wiring alogwith earth wire with the 2 x 2.5 sq.mm. + 1x 2.5 sq.mm. earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alogwith earth wire with the 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Wiring for circuit/ submain wiring alogwith earth wire with the 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (Suitable for the BLDC type fans)
` Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required(5/6 amps switch)
` Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (3 pin 5/6 A socket outlet)
Supplying and fixing suitable size GI box with modular plate and coverin front on surface or inrecess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel,MCB distribution board, 240V, onsurface/ recess, complete with tinned copper busbar, neutral busbar, earthbar, din bar, inter connections, powder painted including earthing etc. asrequired. (But without MCB/RCCB/Isolator (16 way , Double door)
Supplying and fixing following rating,double pole,240V, isolator inthe existing MCB DB complete with connections, testing and commissioning etc. as required(40 A)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (40A)
Supplying and fixing 5 amps to 32 amps rating, 240 volts, "C"-series Miniature Circuit Breaker suitable for inductive load of single pole in the existing MCB-DB complete with connections, testing & commissioning etc. as reqd.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required
Supply of 4 core, 10 sqmm Aluminium Armoured cable, 1.1kV grade
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S. R.K. TRADING AGENCY (BID ID -1147482)
M/S LIGHT PALACE (BID ID -1147395)
R.K SINGH AND SONS (BID ID -1147425)
M/s Subhadra Electricals & Civil Construction (BID ID -1147408)
ASHISH KUMAR AGRAWAL (BID ID -1147593)
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .