Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹16.9 L+₹13,489 (0.81%)Rejected-Finance | L2 | Rejected-Finance Second lowest | |
| 3 | L3₹16.9 L+₹15,301.44 (0.91%)Rejected-Finance | L3 | Rejected-Finance Third lowest | |
| 4 | L4₹17.2 L+₹41,226.44 (2.46%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Fourth lowest |
Tender Value
Refer Docs
EMD Value
₹39,400
Closing Date
14 Dec 2020, 6:00 pmClosed
GE Palampur
Holta Camp Palampur Kangra (H.P) 176061
OUTSOURCING OF SERVICES FOR MAINTENANCE AND OPERATION OF INTERNAL ELECTRIC SUPPLY AT MH AT PALAMPUR AND METER READING AT PALAMPUR AND ALHILAL MIL STN
2020_MES_397021_1
GEP- /2020-21
Open Tender
Civil Works
Item Rate
330 days
Palampur
As per tender docuements
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹39,400
Yes
11 Jan 2021
21 Nov 2020
16 Dec 2020
21 Nov 2020
14 Dec 2020
30 Nov 2020
Amount
SCHEDULE 'A' PART-I:- ( OUTSOURCING OF SERVICES FOR MAINTENANCE AND OPERATION OF INTERNAL ELECTRIC SUPPLY AT MH AT PALAMPUR AND METER READING AT PALAMPUR AND ALHILAL MIL STN) Outsourcing of Services for Maintenance and operation of the Military Hospital by engaging 01 skilled tradesmen (Electrician) (ITI qualified) each shift at Palampur Military Station for three shifts of 8 hours in a day including Sundays & holidays as mentioned below for entire internal Electric Supply from Electric meter board onwards incl repairing to the main DB's , submain DB's , submains , MCB's ,internal wiring, fittings and fixtures, exhaust fans, ceiling fans, geyser maintaince incl repairing to the garden , gate lights complete rectification of faults, attending of complaints on day to day basis complete all as specified and directed by Engr-in-charge.
Outsourcing of Services for Maintenance and operation of the Military Hospital by engaging 01 Helper for Electrician at Palampur Military Station in each shift of 8 hours for three shift in a day including Sundays & holidays as per directions of Engr-in-charge.
Note for Item No 01 to 02:- (i) Inside, surrounding area of the Installations and all equipments shall be maintained neat and clean all the time and the unit rate quoted shall be deemed to incl the cost of the same. (ii) The skilled tradesmen shall be ITI certificate holder & capable to attend emergency repair/ maintenance and complaints as per the directions of Engr-in-charge. (iii) All T&P required for attending complaints and maintenance of plant and installation will be supplied by the contractor and cost is incl in the rate quoted. (iv) Proper attendance register shall be maintained by the contractor. (v) The Tradesmen shall be provided with protective clothings / safety hand gloves /industrial helmets /safety belts/ face masks / rain coat and shall bear that while on duty and the cost is incl in the rate quoted. (vi) The contractor has to provide adequate means to the workmen for conducive work environment and he has to ensure that the workers are covered as per labour law and insurance act. All the tradesmen should be covered under Insurance act vide Indian Electricity Rules, 1956. (vii) The contractor shall be provided with approved colour of uniform for the tradesmen. The rate quoted deemed to be included in the quoted rate. (viii) In case the contractor fails to depute person in shift as asked, then suitable recovery shall be made for the same. Panel reovery @ Rs 600/- per shift shall be recovered in case of operator / technician / helper found absent from duty. (ix) The contractor will provide two sets of complete tools and one commando torch, tool bag which will be used by the technicians and Helpers while on duty at the installtions. The tools will be returned to the contractor on completion of the contract. The rates for the same are deemed to be included in the rates quoted. In case of non provision of tools Rs. 20000.00 will be recovered will be recovered from the contractor due amount. (xii) Contractor has to ensure all COVID - 19 precaution are maintained by preventive materials shall be incl in the quoted rate.
Sch 'A' Part-II (Outsourcing of services for Meter Reading at Palampur & Alhilal Mil Stn) Providing the one meter reader for meter reading work-services including the following:- (a) Noting and recording the readings (using manual or required software) of electronic meters of any type and any capacity located at different premises of consumers at Palampur and Alhilal Mil Stn i.e Md accn of Officers, single accn of Officers, Md Accn of PBORs, Pvt Shops, URCs, Staff Qtrs of KV School, MES/Civil quarters, etc situated at Palampur and Alhilal Mil Stn under the contractor arrangement of conveyance. (b) Entering the readings in user's Meter Reading Cards and also entering in a separate register held with meter reader (Meter Reader Book) duly signed by users of the respective premises and preparation of recovery return for each category of consumer as per schedule of meter reading specified by the department or as directed by Engr-in-charge. (c) Necessary arrangement of conveyance (TPT) for taking meter reading will be borne by the contractor.
(d) Meter reading will be done during only working days and payment will be made accordingly (i.e no payment will be made for Sunday & holidays) Note :- Requisite qualification shall be ITI certificate from recognized institute in Electrician trade or 10th passed with 3 Yrs experience certificate in the relevant filed from the reputed firm/Central/State Govt Deptt.
SCHEDULE 'A' PART-II:- Supply and fix in repairing PVC casing caping of size 20mm complete all as specified.
Supply and fix in repairing PVC insulated & unsheathed FRLS-H multistrand copper conductor wire 1100 volt grade of size 1.5 sqmm complete all as specified.
Supply and fix in repairing PVC insulated & unsheathed FRLS-H multistrand copper conductor wire 1100 volt grade of size 2.5 sqmm complete all as specified.
Supply and fix in repairing T5/T8 tube rod 28 watt 4 feet (2700K/6500K as per requirement) complete all as specified.
Supply and fixing recess / surface mounting LED 2X2 fitting 36 W (2700K/6500K as per requirement) complete all as specified. Make - Bajaj Cat Part No BZRSQL 36W GZ1 CW or equivalent.
Supply and fixing in repairing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed standed conductor 6 sqmm twin core cable flat or circular complete all as specified and directed.
Taking down old unserviceable exhaust fan (PVC body) any type/size, supply and fixing of exhaust fan AC single phase 240 V of size 250 mm sweep 1400 RPM with louvers shutter and making good disturbed complete with connection from ceiling rose to exhaust fan all as specified. Note - Old unserviceable exhaust fan to be deposited in MES store yard.
M/S PARVEEN ENTERPRISES
M/S J N TRADERS
satpal and brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .