| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-Finance | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹28.8 L+₹56,392 (2.00%)Rejected-Finance 37 SUBHASH NAGAR AIR FORCE JODHPUR 342 008 | JODHPUR | JODHPUR | RAJASTHAN | 342008 | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹28.8 L+₹60,358 (2.14%)Rejected-Finance | L3 | Rejected-Finance HIGHEST | |
| 4 | L4₹29.6 L+₹1.4 L (4.89%)Rejected-Finance | L4 | Rejected-Finance HIGHEST | |
| 5 | L5₹30.2 L+₹2.0 L (7.12%)Rejected-Finance PANCHAYATI RAJ ROHTAK | L5 | Rejected-Finance HIGHEST |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
1 Sept 2020, 6:00 pmClosed
SHRI T C SHISHODIYA, DCWE(C)
MULTAN LINE ARMY AREA JODHPUR-342010 (RAJ)
Special Repairs to Bldg No P -922 (C SQN or Accn) of 58 Armd Regt in Army Area Jodhpur
2020_MES_358661_2
CWE (A) JODH-33 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Army Area Jodhpur
4 documents required · 4 mandatory
₹500
GE (A) Central
₹68,000
Yes
27 Oct 2020
17 Aug 2020
2 Sept 2020
17 Aug 2020
1 Sept 2020
18 Aug 2020
Amount
Demolition of reinforcd cement concrete as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including cutting reinforcement etc complete and directed by GE.
M&L for form work to soffits of suspended slabs such as roof slabs floor slabs landing and similar work not exceeeding 200mm thick (horizonal or sloping ) etc all as specifid and as directed of rough finished
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Use and waste of Formwork to edges of concrete flats, treads, , breaks in floors, window cills, concrete railings, openings in concrete walls, floors & roofs n exc 20cm wide & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work exc 10cm but exc 20cm wide
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips L for form work to soffits of suspended slabs such as roof slabs floor slabs landing and similar work not exceeeding 200mm thick (horizonal or sloping ) etc all as specifid and as directed of rough finished
-ditto- all as item No 5 above but 6 to 8 mm dia TMT Bar
-ditto- but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as per item No 05 above.
M&L for RCC M-25 Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for RCC M-25 as in Beams, cantilevers, bressummers, lintels over 1.5m span all as directed by GE.
M&L for RCC M-25 as in Chajjas
M&L for carrying out water proofing treatment for roofs in the following stages first Course : M&L for 10 mm thick plaster with CM 1:3 mixed with water proofing compound as per manufacturee instructions Second Course :One coat of bitumen primer T-10/polymerised confirming to IS 3384 @ 0.30 ltr/Sqm. Third Course : One coat of Bininding material using blown type bitumen conforming to IS 702 grade 85/25 @ 1.20 Kg/Sqm. Fourth Course : A layer of APP membrane polymeric membrane centre core of 100 micron HMHDPE, outer film 20 micron each, thickness 2 mm having weigh 3.00Kg/Sqm Fifth Course : A coat of bonding materail using blown type bitumn conforming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm. Sixth Course : 40mm thick PCC 1:2:4 padding, well compacted using 20 mm graded aggreegate with groovs shall not be exceeding 0.40 Sqmm
Supply only Integral water proofing compund
M&L for PCC 1 : 2 : 4 type B0 using 12.5 mm graded stone aggregate as in roof kerb including weathering, slightly rounded or chamfered angles and throating, as directed etc
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L for 50mm thick PCC 1:3:6 type C-1 using (20mm graded stone Agg) as in plinth protection finished complete including forming joints in 2 mtr inetrvals and filled with bitumen mastic all as drected.
M&L 25mm thick PCC type B-1 (1:2:4) using 20mm graded stone aggregate to receive floor tiles /kota stoneall as specified..
M&L 15mm thick screed bed in CM 1:6 all as specified for laying of floor finishes
Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
-ditto- all as item No 18 above but as in skirting/vertical surface
-ditto- all as item No 18 above but as in treads/risers of step in single piece of stone including bullnose half round to edges of treads etc.
M&L for 18-20 mm thick yellow Jaislmer stone machine cut as in skirting & risers & other vertical surfaces complete over and incl 10 mm thick rendering in CM 1:3 complete
M&L for 18-20 mm thick yellow jaislmer stone mirror polished laid in flooring as in borders or corner stones etc as per approved pattern in flooring over and incl 15 mm thick screeding in CM 1:4 complte all as directed & specified.
M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand blasting scrubbing down concrete surfaces with wire rushes cleaning with water allowed to dry and applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of approved epoxy adjesive on complete exposed surfaces of concrete (Make : FOSROC/SIKA) to be gunited all as specified and applying two layers of guniting over steel welded mesh 2mm dia of wire and aperture 75mm, total thickness of gunite n.exc 25mm thick (average thickness) cement mortar 1:2 using OPC 53 grade cement mixed with polycrete admixture @ 2% by wight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces of required thickness to give even uniform and smooth finish conforming to proper gerometrics in cement meter (1:3) to match with the existing surface as in sides and soffits etc of slabs, chajjas, fins, facias, parapets, columns and beams etc complete including necessary scafflding, shuttering, necessary chases to brick work or RCC members at any height upto double sotrey bldgs incl removing of small trees shurbs etc all as specified. (Note : Steel welded mesh is to be welded with the existing re-inforcement. The cost of welded mesh is deemed to be included in the unit rate quoted.
All as per Ser item No 23 above but thickness of gunite exc 25mm but n.exc. 40mm (average thickness ) -ditto-
All as per Srl item No 23 here - in- before but in patches area n.exc. 1.00 Sq Mtr each.
All as per Srl item No 23 here - in- before but in patches area n.exc. 1.00 Sqm each.
Taking down cement plastering from stone masonry and ceiling etc incl hacking for key scrubbing down with water etc complete all as specified & directed
M & L for rendering 15mm thick to stone masonry surface of wall in CM 1:6 finished even and smooth w/o using extra cement complete all as specified
M&L for Rendering 10 mm thick CM (1:4) on concrete surfaces on ceiling finished even and smooth all as directed and specified.
M&L for three coat of white wash over newly plastered surfaces incl preparation of ceiling etc. all as specified.
M&L for three coat of white wash on newly plastered surfaces incl preparation of previously untreated wall surface.
M/L two coat of OBD on newly plastered/ unplastered surfaces over one coat of chalk whiteing on wall & including preparation
M&L for 10 mm thick rendering as in backing coat of wall tiles, skirting /dados in cement mortar 1:4 all as specified
M&L for Non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement clurry and pointed in white or coloured cement to match
M&L for glazed coloured ceremic tiles in vertical surfaces size 4500x300mmx6 to 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade.
Dismantling structural steel work including window with guard bars doors, gates but excluding framed truss etc.
Taking down chowkhats of any description (with out taking off shutter from the frame) n exc 1.5 Sqm
Taking down chowkhat or frames(without taking off shutters from frame) exc 1.5 sq m but n exc 4 sq m each
S/F of steel window with side hung shutter as shown in Drg No CEJZ/TD/20 sheet 1/3 to 3/3 including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded all as specified.
S/F of steel window with side hung shutter as shown in Drg No CEJZ/TD/20 sheet 1/3 to 3/3 including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded all as specified.
S&F of framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0
S/F of steel ventilator with top hung shutter including hinges with steel handle, and steel peg stay, complete without glazing bars, all as specified.
S&F decorative type powder coated certain rods with double curtain fitting type with brackets fixed to wall complete with two Nos decorative type knobs at end of each curtain rod
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones
S/F of 4mm thick pin headed sheet glass panes of size not. exceeding 0.5 Sqm fixed with oil putty
S/F for 3 mm thick plain glass ordinary quality & glazing.
S&F of Galvanised mild steel wire cloth,0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples
S&F in repairs of Galvanised mild steel wire cloth,0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples
M/L for PCC 1:2:4 type B1 Mix using 20mm graded stone aggregate as in hold fast iron fixing and back filing of pressed steel door frame including necessary form work all as specified.
S&F Pressed steel frames for doors of size 125x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
S/F of 35mm thick 2nd class Hard wood paneled door shutter factory made (two panel) with lock rail andpanel of 9mm thick BWP commercial ply wood, the size of rail and stile is as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated.
S&F 35mm thick 2nd class glazed and skelton shutter, open rebated and prepare to recieive glass, gauge etc (without sash bars)edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass or gauge etc all complete
S&F factory made solid PVC door frames of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube
Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 100mm size butt hinges medium weight (ISI Marked), rolled mild steel complete.
S&F 150mm size extruded aluminium alloy handles, fabricated type anodized complete.
S&F of Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed
s&F of MS 300mm long ordinary rat tail rod pattern springs including roller and roller plate complete
Raking out joints/pointing to square rubble masonry Jodhpur type regular coursed built in cement mortar all as specified
M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in CM 1:3 all as specified.
M&L for two coat of cement based paint on plastered or unplastered surface of wall after preparation of surface
Removing complete existing treatment and preparation of old surffaces by brooming down or steel wire brushinng scraping moulds,moss and effloroscent salts & trading oil and greasy spots to wall including cornices etc plastered or unplastered surfaces (old decorated surffaces) and M&L for applying two coats of white wash on ceiling all as specified and as directed.
Removing complete existing treatment and preparation of old surfaces by brooming down or steel wire brushinng scraping moulds,mossand effloroscent salts &tradiing oil and greasy spots to wall including cornices etc plastered or unplastered surtfaces (old decorated surffaces) and M&L for applying two coat of OBD on newly plastered/ unplastered surfaces over one coat of chalk whiteing on wall all as specified and as directed.
Taking down steel water tubing and connections, 25mm dia including cleaning for re-fixing all as directed.
Taking down steel water tubing and connections, 20mm dia including cleaning for re-fixing all as directed.
Taking down steel water tubing and connections, 15mm dia including cleaning for re-fixing all as directed.
Refxing old 25mm bore steel tubing and connection in new or old position ( walls, ceiling or floor )
Refxing old 20mm bore steel tubing and connection in new or old position ( walls, ceiling or floor )
Supply & Fixing steel tubing 25mm bore medium grade ISI Marked galvanized with and including all fitting fixed on wall, ceiling or laid to floor complete all as specified.
Supply & Fixing steel tubing 20mm bore medium grade ISI Marked galvanized with and including all fitting fixed on wall, ceiling or laid to floor complete all as specified
Supply & Fixing steel tubing 15mm bore medium grade ISI Marked galvanized with and including all fitting on wall, ceiling or laid to floor complete .
Cutting chases for concealed water tubing in stone walls/ concrete block or slabs & walls etc,and making good cutting to facings where required and pointing in CM 1:3, cutting exc. 10cms but n.exc. 20cms girth all as specified and as directed by the Engr-in-Charge.
Dismantling water tanks of capacity exc 500 ltr n exc 1000 ltr and removing to store
S&F1000 ltr Capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S&F of cast iron floor traps, 75mm dia, with SS grating incl jointing to waste pipe fixed in cement conc type B-1 (1:2:4) all as specified.
S&F 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
-ditto- all as item No 24 above but for 25 mm bore pipe
S&F of vitreous china clay water closet ORISSA Pattern size 580x 440 mm white with integral foot rest incl 'P' or 'S' traps, flush pipe of 32mm dia HDPEpipe etc all as specified.
S&f in repair PVC valveless syphonic action type flushing cistern low level white with inlet, ball valve, float and handle including brackets incld 32 mm PVC flush pipe as fixed in repair
S&F in of 15 mm bore Stop valves, ,fancy type, chromium plated with long shank & cup (concealed type) , high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed to 15 mm bore GI Pipe
S&F in repairs Vitrous china wash basin , white flat back size 550 X 450 mm including vitreous china padestral stand , 15 mm CP fancy type pillar tap , waste pipe, MS brackets complete all as specified
S&F in rep Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) Vitreous China urinals,Half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. including PTMT waste coupling , spreader and waste pipe complete
S&F in rep Brass chromium plated shower rose 125mm size
S&F of 600 mm long PVC connction 15 mm size with PTMT nuts of length 600mm.
S/F in repair of 15mm Bib tap fancy type chromium plated, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed
M&L for two caot of synthetic enamel paint to newly steel surface over a coat of red oxide after preparaion steel surface over 10cm in width or grith, not otherwise described over a coat of red oxide after preparaion of new steel surface
M&L for one coat of synthetic enamel paint to old steel decorated surface after preparaion steel surface over 10cm in width or grith, not otherwise described over a coat of red oxide after preparaion of new steel surface
M/L for one coat of synthetic enamel paint on old wooden surface including preparation of surface, over 10Cm width or girth all as specified.
Towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats .(Minimum weight 170gms)
Demolition of stone masonary built in CM all as specilfied and as directed.
M&L for stone slabs as in sun shade chhajas 5cm thick n exc 2.00 mtr length punched dresssed on face and along exposed edges, self faced on other side and set and pointed in cement mortar complete
M&L for squarred rubble walling Jodhpur type regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6 all as specified and directed.
-ditto- all as item No 95 above but except stone
Extra over squared rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing
M&L for Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregate with solid blocks, exc. 10 cm in width and setting in mortar 1 : 6 , complete
M&L for PCC 1 : 3 : 6 type C2 using 40 mm graded stone aggregate as in foundation filling and mass concrete
Excavation in trenches for fdn n.exc 1.5m wide and n.exc 1.5m in depth & getting out in soft /loose soil
S&F for PVC gully trap 125/110mm setting and jointing with solvent cement
Cutting into existing manholes for connecting new drain pipe and making good to pipe and rendering cutting out existing benching for and forming branch (1/2type B-1 smooth finished, and reforming benching as required] round or 3/4th Section) in cement concrete 1:2:4 channel
M&L for cement concrete bed to drain pipes incl forming cradle packing under and haunching etc in PCC 1:3:6 for 150mm thick bedding
M&L for 100mm dia SGSW pipe laid in trenches and jointed as specified
Returning filling in soil including spreading ,levelling,watering and well ramming in layers not exc 25cm
Removing excavated material soil n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point
M&L for 100 thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base complete all as speficed and as directed
M & L 75 mm thick PCC (1:4:8) type C1 using 40mm graded agg as for receiving paver tiles.
M&L for sand filling under floors etc complete incl watering & well ramming complete.
S&F machine made precast cement concrete blocks (Interlocking pavers ) rubberised finished coloure of 60mm thick top layers of anti abrasive material laid over and incl 50mm thick sand cushion. The interlocking tiles joint will be filled with fine sand.
S&F machine made precast cement concrete curb stone blocks using cement concrete 1:2:4 type B1 (20mm graded agg) all as specified and directed.
S&F of CI bend 100 mm bore complete and jointing to pipe
-ditto- all as item No 112 above but 75 mm bore bend
S&F of Cast iron cowls of 100 mm bore pipe
- ditto- all as item No 114 above but 75 mm bore
S&F of Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches for 100 mm bore CI pipe
S&F of Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches for 75 mm bore CI pipe
Dismantling of cast iron or reinforced concrete drain pipes, of 100 mm/75 mm bore jointed in cement mortar and taking out of trenches, if required
S&F Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floorsin repar for CI pipe 100mm dia laid in floor/Wall with cement joint all as spcified.
Ditto as item No 119 above but 75mm dia
Taking down carefully copper/aluminium point wiring for light, fan, bell socket power slocket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose, celing fan etc complete
M & L for Point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC (FR) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked in and including PVC rigid conduit (MMS) ISI marked with accessories fixed Concealed in wall / roof / ceiling etc and including sunken pressed steel terminal boxes in wall and 1.50 sq mm PVC insulated unsheathed stranded copper conductor for common earth and connecting to earth dolly material and labour for :- (a) One light point controlled by one, one way switch
(b) One light point controlled by two two way switchs.
(c) One fan point controlled by one way switch.
(d) One socket outlet 3 pin 5/6 Amps on same board
(e) One socket outlet 3 pin 5/6 Amp on independent board
All as per item No 122 above but with 2.5 Sq mm single core multistanded copper conductor cable for 6 pin 15 Amp socket outlet on independent board .
S&F switch flush type single pole one way 6 Amp ISI Marked .
S&F switch flush type single pole two way 6 Amp ISI Marked .
S&F switch flush type single pole one way 16 Amp ISI Marked.
S&F socket outlet 3 pin, 6 Amp flush type ISI marked.
S&F socket outlet 2 in 1, 6 pin, 6 and 16 amp flush type ISI Marked .
supply and fix socketed stepped type electonic fan regulator ISI marked . flush type.
S & F Ceiling rose, 3 terminal/PVC/ polycarbonate, isolated body ISI marked
M&L for angle holder made out of poly carbonate with metal lamp holder ISI marked with back plate fixed on PVC square block with LED Lamp 7 Watt (CG/ Phillips/Bajaj).
Hanging only ceiling fan of any size, taken down under item no 121 above.connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor of size 0.5 Sq mm from ceiling rose/ connector to fan.
M&L for taking down exhaust fan 300/450mm carefully after disconnecting electrically and mechanically by all means from existing position at location and refixing complete with fastner nut, bolts & washers with S&Fixing louvers made out of MS ,up to the entire satisfaction of Engg-in-charge after completion of electrical work.
Light fittings, with1X0watt LED 230 volt 50 Hz bulk head luminaries, complete with all accessories and including connecting up with PVC insulated and sheathed , 1100 volts grade , flexible , multistranded 1.0 sq mm copper conductor three core cable.
Sup and fixing LED tube light fitting.18/ 20 w, Complete 230 v ( power factor not less than 0.90 ),brightest LED batten, luminous intensity 100/w,Driver Efficienty not less than 90% etc. complete with all accesssories internally pre-wired , connectiong up with PVC insulated and sheathed , 1100 volts grade , flexible , multistranded 1.0 sq mm copper conductor three core cable .
S&F street light .fitting LED Type 1x30W,, single phase 240V comprising of , all fittingslfixtures pre-wired, , with epoxy powder coated, with rubber gasket with hinge arrangement on one side and two latches on the other side including 25 mm dia galvinised iron pipe light grade bracket bent to shape over all length 1.6 mtr fixed to wall with 2 Nos F1 clamps made of 40x6 mm F1 and 15 cm long 8 mm dia boiJts and nuts with washers grouted in wall including , all accessories pre-wired all as specified. Street light fitting Make- CG Model No, LSTN-30 - CDL or equivalent of Phillips/ Bajaj.
M&L for sub main wiring with 2x4 Sq mm single core multistrandred copper conductor PVC insulated and unsheathed (FR) cable incl 4 Sq mm single core copper conductor cable PVC insulated and unsheathed (FR)cable as earth wire. , passing through in and including PVC conduit ( MMS), ISI marked with accessories fixed to surface of wall/roof/ceiling etc. and making good the distrurbed surface of wall Note :-(i) Two runs of cable 4 Sqmm and One run of 4 Sqmm along with PVC conduit shall be measured as unit length.
S&F distribution board double door , in sheet metal enclosure dully flushed in wall, when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS TPN 4 way suitable for fixing MCCB 4 Pole as incomer and MCB for out going.
Taking out old U/S DB's with wooden board / boxes S&F distribution board manufacturer prewired , IP 42 in sheet metal enclosure dully flushed in wall, when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 12 way cat no.- SD 3707,
Taking out old U/S DB's with wooden board / boxes S&F distribution board manufacturer prewired , IP 42 in sheet metal enclosure dully flushed in wall, when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 4 way cat no.- SD-3809 ,
S& F MCCC 4 Pole 100 A mps 16 KA
S& F MCB SPN 25 amps 10 Ka, "C' series
S&F MCB single pole 5 to 30 Amps, 10 Ka, "C' series
M & L for earthling complete with galvanized Steel earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and incl galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or controll board GI pipe light grade 20mm bore for watering funnel with wire mesh PCC chamber pit in PCC 1:3:6 type C-1 40mm yhick Precast RCC -25 cover reincorced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as sprecified and shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Supply,laying and fixing only along the poles,floor, ground or passing through walls etc jointing and testing LT Cross Linked Polythene Insulated galvanised steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC of cross sectional area 16 sqmm x 4 core ISI marked ,all as directed by Engg-in-charge.
Supply and fixing MCCB 125 Amps 25 KA including sheet metal enclosure powder coated finish and fixed flush in wall including making good to distrubed surface etc complete.
Supply and fixing Sheet metal Busbar chamber factory fabricated powder coated finish complete with copper busbar TPN 250 Amps including fixing arrangement etc complete
Excavating in trenchs in soft/loose soil, n exc 1.5m wide and n exc 1.5m in depth; for laying of cables etc. n.exc 10sq m on plan and n exc 1.5m in depth and getting out .
Removing surplus excavated material (soil) not exceeding 50 metre and deposRing where directed at a level not exceeding 1.5 metre above the starting point.
Returning, filling soil, including, spreading, levelling, watering and well rammin in la ers not exceeding 25 cm thick complete.
S & L Jodhpur stone quarry faced stone slab cover 40 to 50mm thick, 25cm to 30cm wide, 60cm long, laid dry and abutting each other with gap cetween adjacent slab not exceeding 10mm over under ground cables for protection.
Sand cushioning to under ground cable using river sand and gently punning for cushioning to cable all as specified.
S&F Pipe galvanized iron light grade complete with all fittings laid in road crossing, and on pole, floors buildings complete all as specified and directed ISI marked. of 40mm bore.
DEV INDUSTRIES
Rajesh Enterprises
S. D. Construction Co.
HOODA CONSTRUCTION COMPANY
Harsh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .