Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-Finance | L1 | Accepted-Finance 1st lowest | |
| 2 | L2₹49.2 L+₹84,765 (1.75%)Accepted-Finance | L2 | Accepted-Finance 2nd lowest | |
| 3 | L3₹58.6 L+₹10.2 L (21.1%)Accepted-Finance | L3 | Accepted-Finance 3rd lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical CLARIFICATION NOT FURNISHED |
Tender Value
Refer Docs
Closing Date
8 Feb 2021, 2:00 pmClosed
Executive Engineer Mech. Div Kgl
Office of the Executive Engineer Mech. Div Kgl
Supply, Installation, Testing and Commission of wall mounted Electric Heating Panel system to Residential Quarters of Chief Executive Councilor LAHDC Kargil
2021_PWD_2069_1
MDK/e-NIT/50 of 2020-21
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
30 days
Residential Qtrs at Kurbathang Kargil
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
Executive Engineer Mech. Div Kgl
Exempted
Office of the Executive Engineer Mech. Div Kgl
17 Mar 2021
29 Jan 2021
8 Feb 2021
30 Jan 2021
8 Feb 2021
30 Jan 2021
4 Feb 2021
Amount
Supply, installation testing and commissioning of wall mounted electric panel heating elements of following specifications: The job also includes providing and fittings of all kind of mountings and accessories of proper size and specifications, complete as required, to provide correct services and operations as are intended for. The panels shall be so arranged that a set of panel shall not exceed 2 KW of load
Size= ‘2x3’ (6 Sft) Input Voltage range= 140-230V Cap= 450-watt Surface Temp. Range= 60-85oC Heat Output range =150-350 K.Cal./Hr Material=MS
Size= 1’x2’ (2 Sft) Cap= 100-W-150-W Input Voltage range= 140-230V Surface Temp. Range= 60-85oC Heat Output range=50-150 K. Cal./Hr Material = MS
Supply and fixing of THERMOSTAT suitable for 3-kw rating to control room temperature. The thermostat shall be suitably connected to the electrical circuit. Job incld. make good of disturbed surface to match with existing surface including connection, complete.(for 3-kw)
Supply and fixing of sheet metal enclosure for TPN 24- way DBs Double Door with 200Amps rated bus-bar 440 volts AC, IP 53 protection, double door, concealed in wall including making good of disturbed surface to match with existing surface including connection complete.
Supplying and fixing 32 A rating, 240 V, 10 kA, "C" curve, MCB (miniature circuit breaker) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) Single Pole and Neutral
Supply and Fixing of MCBs TPN 63 Amps C Characteristics of 10KA breaking capacity, including all incoming and outgoing electric connection complete
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4-sq-mm from distribution board to socket 2.5-sq-mm from socket to panel board The job also include providing and fitting of thimbles.
I) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
II) 2X2.5 sq.mm+1X2.5 sq.mm earth wire
Supply and fixing XLPE cable, insulated, screened, electric power cable (heavy duty) 1100 volts grade with standard Cu conductor of following size including end termination/Thimbligs from panel board to distribution board 16-Sq-mm 3.5 Core Copper cable from main panel to distribution board 150-Sq-mm 3.5 Core Aluminium cable from LT Pole to AVR/Panel
I) 16 Sq mm 3.5 core (Copper Cable)
II) 300 Sq mm 3.5 core (Al)
FULLY AUTOMATIC SERVO VOLTAGE REGULATOR SITC of Fully Automatic Voltage Stabilizer/Regulator Duly Filled With Recommended Oil Upto Full Capacity. The AVR shall have following specifications: Type = Fully Automatic Servo Voltage Regulator Rating 180- KVA Input Voltage Range (Phase To Phase) =260-460 V Output Voltage Range (Phase To Phase) =415±1% Output Wave Form = True To Input Input Frequency = 45-55 Hz Response Time = 10 Msec Correction Speed = 25-65 V/Sec Correction Method = Stopless Correction Cooling = Oil cooled Efficiency = 98% (or Better) Control Circuit = Fully Automatic IC Based Solid Stat, Operation = Fully Automatic Suitability = Suitable For 3-PhaseUnbalanced Supply Operating Temperature Ambient = -40°CTo 45°C or Above
Maintenance Free Eearthling:- S.I.T.C. of long life maintenance free electrolytic earthling system with 10 feet vertical k type copper not less than 2”( 50.8mm) ID and not less than 0.08” (2.03mm) wall thickness ,which does not require manual addition of water .The system should be corrosion resistant pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. Rated for high fault currents bas bar rated for 10KA, fault current bus bar connection type as “Terraweld” to withhold temperature of 7000C.The earthling port shall be designed and supplied with poly plastic port cover nonconductive, environment friendly and lockable. The job includes excavation of pit, disposal of earth, installation of rods refilling with suitable earth and leveling copper strip etc.
Supply, installation, testing and commissioning of acoustic enclosed D.G set generating 40-KVA power at 1500 RPM rated for continuous duty with an additional 10% overload capacity for one hour in a period of 12 Hours of continuous operating at site conditions and confirming to standard operational BS 649/5514,BS 649/5514 inclusive of all standard accessories and instruments panel synchronous alternator 40 kva AC 3phase 415 V 50Hz 1500 RPM 0.8 power factor alternator shall be in SPDP enclosure self-erected ,self-regulated confirming to IS 4722/BS 2613 complete with Battery, Base frame ,Fuel system/tank. Acoustic enclosure: Acoustic enclosure suitable for 40-KVA D G set and fabricated from high grade cold rolled cold annealed (CRCA) sheet and steel members lined with density sound absorption material to reduce the sound level to 7-75 decibels measured from distance of 3 meters away from the set. The job includes providing and fixing of fuel piping and valves, fuel transfer pump, Power cables, Cable and termination.
M/S ARYAN ENGINEER AND BUILDERS , KARGIL
M/S Mohammad Khan
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .