| Sl No | Description | Qty | Unit | Nazir Hussain L1 | Bhat Electrical and Mechanical Works L2 | M/S CHOUDHARY ELECTRICAL WORKS L3 |
|---|---|---|---|---|---|---|
| 1.0033 KV LINE | ||||||
| 2.00 | Supply & Erection of 11 Mtr long ST Poles 410 SP-56 complete along with pit excavation and 1/6 th of pole embedded in soil as per relevant REC standards. | 167 | Nos | 30,000 ₹50,10,000 Lowest | 33,500 ₹55,94,500 | 32,000 ₹53,44,000 |
| 3.00 | Supply & Erection of 13 Mtr long ST Poles (ST-540- SP69) complete along with pit excavation and 1/6 th of pole embedded in soil as per relevant REC standards. | 4 | Nos | 34,000 ₹1,36,000 Lowest | 40,000 ₹1,60,000 | 35,000 ₹1,40,000 |
| 4.00 | Providing, Erection and fixing of GI V cross arm with Top bracket including clamps, braces & washers as per relevant Standards | 3,825 | Kg | 170 ₹6,50,250 Lowest | 210 ₹8,03,250 | 170 ₹6,50,250 Lowest |
| 5.00 | Providing, Erection and fixing of GI Channel cross arm including clamps, braces & washers as per relevant Standards | 1,440 | Kg | 170 ₹2,44,800 Lowest | 210 ₹3,02,400 | 170 ₹2,44,800 Lowest |
| 6.00 | Supply, Laying, Stringing and binding of 0.1 ACSR Conductor with jumpering at tension points as per relevant standards. | 28 | km | 1,81,000 ₹50,68,000 | 1,52,000 ₹42,56,000 Lowest | 1,80,000 ₹50,40,000 |
| 7.00 | Heavy duty Pressure di-cast aluminium 630A PG-clamps suitable for 0.1 ACSR Conductor | 40 | Nos | 250 ₹10,000 Lowest | 450 ₹18,000 | 700 ₹28,000 |
| 8.00 | Providing and fixing of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards | 513 | Nos | 750 ₹3,84,750 | 700 ₹3,59,100 Lowest | 900 ₹4,61,700 |
| 9.00 | Providing and fixing of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards complete with suitable tension fittings | 108 | Nos | 1,900 ₹2,05,200 | 1,200 ₹1,29,600 | 1,100 ₹1,18,800 Lowest |
| 10.00 | Providing and fixing of G.I. Nuts & bolts as per relevant REC standards. | 171 | kg | 170 ₹29,070 Lowest | 210 ₹35,910 | 170 ₹29,070 Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.7 L
Closing Date
18 Aug 2025, 4:00 pmClosed
EXECUTIVE ENGINEER STD-IV JPDCL KALAKOTE
EXECUTIVE ENGINEER STD-IV JPDCL KALAKOTE
SUPPLY, ERECTION TESTING, COMMISIONING OF 33 KV LINE OF NEWLY UNDER CONSTRUCTION RECEIVING STATION SADDAMANDI UNDER THE JURISDICTION SUB-TRANSMISSION DIVISION (JPDCL) KALAKOTE UNDER UT CAPEX
2025_PDD_283304_1
STD-IV/JPDCCL/33OF 2025,
Open Tender
Electrical Works
Turn-key
180 days
Kalakote
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,000
EXECUTIVE ENGINEER STD-IV JPDCL KALAKOTE
₹2.7 L
22 Sept 2025
5 Aug 2025
19 Aug 2025
5 Aug 2025
18 Aug 2025
5 Aug 2025
Amount
33 KV LINE
Supply & Erection of 11 Mtr long ST Poles 410 SP-56 complete along with pit excavation and 1/6 th of pole embedded in soil as per relevant REC standards.
Supply & Erection of 13 Mtr long ST Poles (ST-540- SP69) complete along with pit excavation and 1/6 th of pole embedded in soil as per relevant REC standards.
Providing, Erection and fixing of GI V cross arm with Top bracket including clamps, braces & washers as per relevant Standards
Providing, Erection and fixing of GI Channel cross arm including clamps, braces & washers as per relevant Standards
Supply, Laying, Stringing and binding of 0.1 ACSR Conductor with jumpering at tension points as per relevant standards.
Heavy duty Pressure di-cast aluminium 630A PG-clamps suitable for 0.1 ACSR Conductor
Providing and fixing of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards
Providing and fixing of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards complete with suitable tension fittings
Providing and fixing of G.I. Nuts & bolts as per relevant REC standards.
Providing and fitting of danger plates on each pole as per relevant standards
Providing and fitting of Anti climbing devices with clamps on each pole as per relevant standards
Providing and fixing of Earthing Complete of Steel Tubular Poles by GI Pipe 40 mm 3 mtr long through GI Strip 25x3mm as per relevant REC standards.
Providing and painting of 11 mt S.T Poles with two coat of Red Oxide Paint of reputed make as per relevant standards
Providing and painting of 11 mt S.T Poles with two coats of Aluminium Paint of reputed make as per relevant standards
Providing and laying of Cement bottoming for 11 mtr. S.T Poles 1:2:4 mix as per REC standards (0.6 cum/pole)
Providing and fitting of Aluminium Jointing Sleeves as per relevant REC standards
Galvanised Stay Set with 50 x 8 mm stay clamp, guy insulator(2Nos.), anchor plate (300x 300 x 8 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete as per relevant standard
Supply & Laying of Guard Netting as per relevant standards.
Bhat Electrical and Mechanical Works (BID ID -2445473)
M/S CHOUDHARY ELECTRICAL WORKS (BID ID -2443845)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .