Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-Finance | L1 | Accepted-Finance BEING L1 | |
| 2 | L2₹8.0 L+₹10,135 (1.29%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite category | |
| 4 | Rejected-Technical DOOR NO 1 1 K M PALEM VILL A KOTHAPALLI POST DEVARAPALLI MD ANAKAPALLI DIST 531 022 | ANAKAPALLI | ANDHRA PRADESH | 531022 | - | Rejected-Technical Not enlisted in requisite category | |
| 5 | Rejected-Technical | - | Rejected-Technical not enlisted in requisite category |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
17 Oct 2024, 6:00 pmClosed
Madhab Chakraborty, AE
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8561 CERATIN REPAIRS TO 33 KV POWER TRANSFORMERS AND 11KV DISTRUBUTION TRANSFORMERS, 2/ 4 POLE STRUCTURES (33/ 11 KV) INCLUDING DEHYDRATION/ ROUTINE MAINTENANCE AT NSTL AREA UNDER AGE (I) R n D NSTL, VISAKHAPATNAM
2024_MES_676767_1
AGE I R AND D NSTL VIZAG 8561
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Visakhapatnam
Class E, Cat b(iii)
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹19,000
Yes
20 Nov 2024
26 Sept 2024
19 Oct 2024
26 Sept 2024
17 Oct 2024
3 Oct 2024
Amount
M&L for filteration of transformer oil of step down 33 KV /11 KV indoor/outdoor type Transformers installed at different sub stations & locations of NSTL Area ,testing of dielectric strength of transformer oil of indoor/outdoor type transformer,33KV/11 KV volt, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to 60 KV for 1 minute at 4 mm gap including new transformer oil for toping up & testing after filtration complete as specified. (Note: Extra Transformer oil will be measured & paid seperately.)
M&L for filteration of transformer oil of step down 11 KV / 0.433 KV indoor/outdoor type Transformers installed at different sub stations & locations of NSTL area,testing of dielectric strength of transformer oil of indoor/outdoor type transformer,11 KV/0.433 KV filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to 90 KV for 1 minute at 4 mm gap including new transformer oil for toping up & testing after filtration complete as specified. (Note: Extra Transformer oil will be measured & paid seperately.) Notes for Item Nos 1&2: (a) The contractor will take shut down orders in working before commencement of the work from Engineer-in-charge. (b) The contractor shall ensure no wastage at transformer oil. (c) The Contractor is solely responsible for any damage to the transformer during filetration operations. He is responsible for making good any damage to the transformer at his own cost without any extra cost to the department (d) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration. (e) The di-electric strength of oil shall be tested before & after filtration. Test results shall be submitted to Engineer-in-charge
Supply and fix in repair silica gel breather assembly with first fill of silica gel suitable for upto 1600 KVA Transformers complete including connecting with proper rubberized gasket complete including necessary GI fitting complete all as specified and directed. Make : Patel Electrical Industries or equivalent recommende by OEM
All as per item No 3 above but suitable for Capacity of transfomer 3150 KVA to 5000KVA
Supply and filling Silica gel in Breathers of Transformers all as specified. Note: The Silica Gel shall be brought in Air-tight container.
Supply and fix Temperature gauge meter suitable for outdoor/indoor type 11/0.433 KV transformers of capacity up to 1600 KVA including taking down unserviceable one from the transformer complete all as specified and as directed.Make :-Precisemeasure or its equivalent.
Supply and fix Winding temperature indicator & oil temperature indicator suitable for outdoor/indoor type 33/11 KV transformers of capacity up to 5000 KVA including taking down unserviceable one from the transformer complete all as specified and as directed.Make :-Precisemeasure or its equivalent recommended by OEM.
Material and labour for Spray painting with Silicon Acrylic heat resistant paint of approved quality & colour to indoor/outdoor type, step up/ down transformer of capacity up to 500 KVA, installed at different locations at NSTL after thoroughly scrapping the existing corroded paint/ rust, filling of cavities complete without disturbing/ damaging the electrical network system including writing the details such as SM/ MES No, Capacity/ Rating/ Incoming and outgoing details all as specified and directed.
All as per item No 8 above but from 630 KVA to 1600KVA
All as per item No 8 above but from 3150 KVA to 5000KVA
Supply and filling new Transformer Oil in sealed drum with di-electric strength of 60 KV for topping up the transformer & Extra oil required for repaired transformers complete all as specified and as directed. Make : Power Oil/ Electrol/ Servo/Savitha
Supply and replacement of burnt transformer oil with new Transformer Oil in sealed drum with di-electric strength of 60 KV for topping up the transformer & Extra oil required for repaired transformers complete all as specified and as directed. Make : Power Oil/ Electrol/ Servo/Savitha. Note : (a)The transformer oil shall be type EHV confirming to IS - 335(2018) (b) Mineral oil grade shall be used. (c) The transformer oil should have a high dielectric strength not less than 60 KV/Min
M&L for disconnecting the existing HT/ LT electrical connections of defective transformer terminals and shifting the transformer of any capacity from existing position to workshop for repairs, and reinstalling the same after repairs in position including necessary testing after reinstalling the transformer complete all as specified and as directed. Notes :- (i) Repair/ replacement of transformer parts shall be measured and paid separately under respective items of BoQ. (ii) The unit rate quoted shall be deemed to include for the cost of shifting of transformer to workshop and back to position.
M&L for opening the transformer cover along with the conservator by removing the nuts,bolts then after removing the internal HT & LT connections by taking them out by removing studs,bushings,taking out the core winding assembly out of the tank,removing out burnt HV& LV windings from the core assembly,cleaning of core assembly with CTC including necessary repairs for the unserviceable transformers having ratio 11/.433 KV ,draining & decanting of burnt transformer oil and cleaning of sludge deposited in the tank with CTC for the transformers.Rewinding of HV & LV coils with suitable turns & size of super enamelled copper wire/strip winding material measured separately(As existing) having suitable class insulation material.Heating of core winding assembly as per existing procedure & removing the moisture present in it,removal of leakage of tank if any by welding,refilling transformer oil to tank,after putting the core winding assembly in to tank,reassembling making the internal HT & LT connections by fixing the studs,bushings,fitting the top cover by replacing the cork sheet gasket along with conservator ,testing the trnsformer in the workshop duly filled with oil all as specified and directed by Engr-in-charge. Notes: (i) The unit rate quoted shall be inclusive of varnish sleeving of insulating material, taking down the clamps, upper channels and core & HT links and re-clamping, positioning with separators, brazing etc complete. (ii)Weight of copper coil, HT & LT insulation shall be considered for payment. (iii)Replacement of of u/s items such as HT & LT bushings,studs,nut,bolts & washers shall be paid separately. (iv) Extra Transformer oil will be measured & paid seperately. (v)Synthetic rubber cork sheet gasket will be measured & paid separately.
Supply & replacement of super enamealled copper winding wire/strip of suitable guage as per existing for H.T &L.T coils of transformer of capacity up to 1600 KVA & 11/0.433 KV including providing HT< insulation complete all as specified and directed by Engr-in-charge.
Supply and Fix in replacement of HV bare porcelain bushing with insulator,stud,nuts & washers of rating 12 KV, 250 to 630 Amps complete suitable for indoor/ outdoor type, step up/ step down transformers of any make/ model complete all as specifieed and as directed.Make :Pactil/Jaypura/WSI
Supply and Fix in replacement of LV Porcelain bushing with insulator,stud,nuts & washers of rating 1.1 KV, 400 to 100 Amps complete suitable for indoor/ outdoor type, step up/ step down transformers of any make/ model complete all as specifieed and as directed.Make :Pactil/Jaypura/WSI
Material and labour for Transformer Oil Leakage arresting by providing synthetic rubberized cork sheet gasket 6mm thick for top cover HT/LT bushes at places existing and tighting all the bushings and top cover including Taking down unserviceable sheet gasket (Cork sheet),transformer capacity of 11/.433 KV 100 KVA to 1600 KVA complete all as specified and directed
Material and labour for Transformer Oil Leakage arresting by providing synthetic rubberized cork sheet gasket suitable thickness for top cover HT/LT bushes at places existing and tighting all the bushings and top cover including Taking down unserviceable sheet gasket (Cork sheet),transformer capacity of 33/11 KV 3150 KVA to 5000 KVA complete all as specified and directed
M & L for Low voltage testing of 11KV/433V 100 to 1600 KVA distribution Transformer ie open circuit test,short circuit test, magnetizing current, Magnetic balance & IR Value test complete all as specified and directed by Engr-in-charge.
M & L for Low voltage testing of 33KV/11 KV 3150 to 5000 KVA distribution Transformer ie open circuit test,short circuit test, magnetizing current, Magnetic balance & IR Value test complete all as specified and directed by Engr-in-charge.
M & L for Shifting of Transformer of any capacity from variours substations/Locations at NSTL area by road using and removing the faulty transformer by fxing/errecting of the healthy tansformer with the hydraulic crane support making the necessary HT/LT cable connections earth connections and restoration of power supply all as specified and directed.
M&L for Preparation of old painted surface of HT 11/33 KV Panel boards, Cable duct of any size by scrapping including hinges, doors and applying two coats of synthetic enamel paint over a coat of zinc chrome primer on new steel surfaces complete all as specified and directed.
Supply and Replace Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT 33 KV/11KV, 25x20cm size including taking down of old plate all as directed.
Taking down unserviceable indication lamp holder and S&F in repairs indicating lamp holder with bulb LED(Red Yellow,Blue,Green) type to indicate incoming supply suitable for 24 V DC/110 VAC/230Volts AC and all as specified and directed. Make:Teknic/ C&S /L&T
M & L for repair to GOD switch 33 KV HT mechanically operated horizontally operated by cleaning of moving/static contacts with tetra chloride solution, scrapping and making smooth to existing spot points of the contacts by emery paper, providing grease on moving contacts, mechanical torque joint, tightening of canopy with drop out fuse set (three contacts in each GOD) complete all as specified and as directed by Engineer-in-Charge.
Supply and laying 40 mm graded stone aggregate under 2/4 pole structure around the 2/4 pole structure complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of oil drain valve suitable for 200 KVA to 1600 KVA transformers of indoor/out door type complete all as specified and as directed by Engineer in charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 x 60 cm and 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below ground level connected to galvanised GI earth strip 32 x 6 mm size by means of nuts, bolts, check nuts and washers of the galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS Funnel, Wire Guage, 50 mm thick precast RCC Coverin Type B1 including necessary excavationin any type of soil, returning, filling in, removal of surplus soil to a distance n exc 50 m, char coal and salt complete all as shoen in electrical Plate No. 3of SSR Part-1 2009 and conecting to earth test point all as specified and as directed. Note : Contractor should submit test results of earthings.
Material & Labour of GI earth strip of size 32 x 6 mm in trenches/fixed to walls/ transformer/LT panel /2 pole/4 pole with saddles and fixing screws etc., from earth pit to test point all as specified and directed.
M/S CHANDRA ENGINEERS AND CONTRACTORS (BID ID -3142358)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .