Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹9.8 L+₹27,469 (2.88%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹12.0 L+₹2.4 L (25.3%)Rejected-Finance | L3 | Rejected-Finance Due to L3 | |
| 4 | L4₹12.4 L+₹2.8 L (29.8%)Rejected-Finance | L4 | Rejected-Finance Due to L4 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
8 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
REPAIRS/RENEWAL OF LT UG CABLES AND LT OH LINES ALONG WITH CONNECTED ITEMS OF DOMESTIC AND TECHNICAL AREA UNDER GE (AF) BIDAR
2023_MES_613237_1
8245/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹36,000
Yes
17 Jan 2024
11 Aug 2023
9 Sept 2023
11 Aug 2023
8 Sept 2023
25 Aug 2023
Amount
Taking down LT XLPE / PVC UG cable 1100 V grade of 400 Sqmm 3.5 Core connected from LT OH line to MCB DB, between the poles, transformer to LT Panels complete all as specified and as directed. Note: - Excavation and Earth work will be measured and paid seperately under the respective items
All as per Item No. 1 here in before but of Size 240 sqmm 3.5 core
All as per Item No. 1 here in before but of Size 185 sqmm 3.5 core
All as per Item No. 1 here in before but of Size 120 sq.mm 3.5 core
All as per Item No. 1 here in before but of Size 95 sq.mm 3.5 core
All as per Item No. 1 here in before but of Size 70 sq.mm 3.5 core
All as per Item No. 1 here in before but of Size 50 sq.mm 3.5 core
All as per Item No. 1 here in before but of Size 35 sq.mm 3.5 core
All as per Item No. 1 here in before but of Size 25 sq.mm 3.5 core
All as per Item No. 1 here in before but of Size 16 sq.mm 4 core
All as per Item No. 1 here in before but of Size 10 sq.mm 4 core
Relaying of serviceable cable of size 400 Sqmm 3.5 Core complete all as specified and as directed.
All as per Item No. 12 here in before but of Size 240 sqmm 3.5 core
All as per Item No. 12 here in before but of Size 185 sqmm 3.5 core
All as per Item No. 12 here in before but of Size 120 sq.mm 3.5 core
All as per Item No. 12 here in before but of Size 95 sq.mm 3.5 core
All as per Item No. 12 here in before but of Size 70 sq.mm 3.5 core
All as per Item No. 12 here in before but of Size 50 sq.mm 3.5 core
All as per Item No. 12 here in before but of Size 35 sq.mm 3.5 core
All as per Item No. 12 here in before but of Size 25 sq.mm 3.5 core
All as per Item No. 12 here in before but of Size 16 sq.mm 4 core
All as per Item No. 12 here in before but of Size 10 sq.mm 4 core
Supply, lay, connect, test and commisioning of LT XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor multistranded 400 Sqmm 3.5 Core, 1100 volts grade including connecting the cable ends to the LT Panel/ Transformer /LT OH lines and distribution board complete all as specified and as directed. Note: (i) The rates quoted deemed to be inclusive of necessary end terminations connecting materials such as lugs, nut bolt washers, aluminium jumper wire to suits the existing system.
All as per Item No.23 here in before but of Capacity 240 sq.mm 3.5 core
All as per Item No.23 here in before but of Capacity 185 sq.mm 3.5 core
All as per Item No.23 here in before but of Capacity 120 sq.mm 3.5 core
All as per Item No.23 here in before but of Capacity 95 sq.mm 3.5 core
All as per Item No. 23 here in before but of Capacity 70 sq.mm 3.5 core
All as per Item No. 23 here in before but of Capacity 50 sq.mm 3.5 core
All as per Item No. 23 here in before but of Capacity 35 sq.mm 3.5 core
All as per Item No.23 here in before but of Capacity 25 sq.mm 3.5 core
All as per Item No. 23 here in before but of Capacity 16 sq.mm 4 core
All as per Item No. 23 here in before but of Capacity 10 sq.mm 4 core.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out / for laying under ground cables / pipes etc and getting out in soft/loose soil complete all as specified and as directed.
Supply and spreading natural river sand in trenches for cushioning of under ground cable complete all as specified and as directed. Note: Punned thickness will be measured and paid for purpose of the payment.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed .
Removal of surplus excavated material ( soils) to a distance not exc., 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
Supply and laying unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and as directed.
Relaying serviceable unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and as directed.
S&F in repairs GI Steel tubing light grade of 40mm dia with fittings in trenches/wall/poles for cable protection complete all as specified and directed.
S&F in repairs GI Steel tubing light grade of 50mm dia with fittings in trenches/wall/poles for cable protection complete all as specified and directed.
S&F in repairs GI Steel tubing light grade of 80mm dia with fittings in trenches/wall/poles for cable protection complete all as specified and directed.
Steel tubular swaged poles type 410 SP-31 (9metres long) with cast iron base plate, finial taper plug, bolts, nuts & screws including disconnecting and removing the u/s LT street light steel tubular pole complete all as specified and as directed. Note: 1 Excavation & earth work, RFR, removal deemed to be included in the unit rate quoted. 2. PCC 1:3:6 for foundation and 1:2:4 for coping will be measured and paid separately under respective items of the schedule.
ACSR conductor including cut to length as per site requirement including disconnecting and removing the u/s ACSR conductor complete all as specified and as directed. Note: Cost of stringing, binding the conductors to the insulators and all Misc items required for satisfactory completion of work deemed to be included in the unit rate.
Pin type, porcelain, vitreous, white, brown or green insulator 100mm height, 65mm dia. 1100 volts grade ISI Marked including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, along with fixing material such as GI bolt,nut and washers etc. including disconnecting and removing the u/s pin insulators complete all as specified and as directed.
Shackle type porcelain, vitreous, white, brown or green insulator 75x90mm including galvanised mild steel straps washers, insulator bolts & nuts including disconnecting and removing the u/s shackle type insulators complete all as specified and as directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecing and removing the u/s mild steel cross arms complete all as specified and as directed.
PVC line separators between conductors suitable for 1100 volts LT supply including disconnecting and removing the u/s PVC line separators complete all as specified and as directed.
PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation for pole complete all as specified and as directed.
PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping for pole including necessary form work complete all as specified and as directed.
Trimming the branches of trees touching the OH electric conductors and around the street light fitting upto 1.5m radius and removing the same from site, cleaning and depositing where directed complete all as specified and as directed. Note: (1) Any damage caused to the infrastructure during trimming shall be made good by the contractor without any extra cost. (2) Distance between two LT poles shall be considered as one span.
Cleaning and preparation of old painted surfaces and applying one coat of aluminium paint on LT steel tubular swaged pole upto 7.5m (length of pole to be painted 6.00 Rm) including MS angle iron cross arms, channels, clamps, street light brackets and writing pole number with white paint on 5" dia black background complete all as specified and as directed .
Writing pole number with white paint on 5" dia black background on PCC poles complete all as specified and as directed.
Re-stringing of ACSR conductor of different sizes and earth wire after removing the ACSR conductor from the existing LT OH lines including Jumper connections, binding wires of insulators and removing the sag of Over head lines and refixing in existing position complete all as specified and directed.
Stay assembly consisting of stay rod of dia 16 mm complete with accessories as shown in electrical plate No. 1 including dismantling u/s stay assembly complete all as specified and directed. Note: Loop Insulator, concrete will be measured & paid separately under the respective item of the schedule.
S & F in repairs Loop insulators, vitreous porcelain 1.1 KV of size 65 x 90 mm, clearance of hole 16mm for looping stay wires or ground conductors complete all as specified and as directed.
Straight through joints (EPOXY) for 1100 volts grade under ground cable including jointing kits with jointing materials, necessary earth work / excavation and removing existing damaged joints / cable complete for cable of size 3.5 core 400 sqmm complete all as specified and as directed.
Satish Patpally
Siddique constructions
Mr Madhusudhan Kotarki
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .