Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹16.1 L
EMD Value
₹32,160
Closing Date
17 Oct 2023, 2:00 pmClosed
Executive Engineer ED Baramulla
Executive Engineer ED Baramulla
Creation of 63kVA Sub Station at Kohlina Under MPLADS 2023-24
2023_PDD_231337_1
EDB/102
Open Tender
Electrical Works
Turn-key
45 days
Creation of 63kVA Sub Station at Kohlina Under MPL
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,008
Yes
Executive Engineer ED Baramulla
₹32,160
Yes
20 Oct 2023
27 Sept 2023
18 Oct 2023
27 Sept 2023
17 Oct 2023
27 Sept 2023
27 Sept 2023 - 27 Sept 2023
Amount
Supply,Carraige upto site, Installation, testing and Commissioning of 11/0.433kV, 63kVA 3-Phase Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Alminium wound and with LV Cable Box having detachable Alminium Gland plate with LV Bimetallic terminal connection suitable for vertical take off cable.
Supply,Carraige upto site, Erection, testing and commissioning of Steel Tubular Pole, 9 Mtr. Long Pole(ST-410 SP33) with planting depth of 1/6 th of the height of the pole, (9 mtr. Long )
Supply, Carriage up to site, Erection, testing and commissioning of Steel Tubular Pole, 8 Mtr. Long Pole(SP15) with planting depth of 1/6 the of the height of the pole, (8 mtr. Long )
Supply, Carriage up to site, laying ,stringing, tensioning , binding of ACSR Conductor, (30mm2 ACSR Conductor)
Supply, Carriage up to site, laying ,stringing, tensioning , binding of ACSR Conductor, (50mm2 ACSR Conductor)
Supply,Carraige upto site, Installation, testing and Commissioning of G.I Channel / Angle / Flat of sizes including Clamps
Supply,Carraige upto site, Installation, testing and Commissioning of G.I Channel V-X arms 75x40x6mm with Top bracket including suitable clamps/collars (06Nos.) As per REC Standard
Supply,Carraige upto site, Installation, testing and Commissioning of 11KV Polymeric composite pin insulators 12kV, 5kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm
Supply,Carraige upto site, Installation, testing and Commissioning of 11KV Polymeric composite disc insulators 12kV, min falling load 45kN, lightening impulse 75kV positive and 80kV negative , creepage distance 320mm
Supply,Carraige upto site, Installation, testing and Commissioning of 11KV G.O, AB switch 3-phase, 3pole,200Amp, vertical type
Supply,Carraige upto site, Installation, testing and Commissioning of 11kV Horn Gap Fuse Set 3 Phase 200A
Supply,Carraige upto site, Installation, testing and Commissioning of 11kV Gapless surge arrestor, 9 kV, 10kA, LA with polymer housing station type
Supply,Carraige upto site, Installation, testing and Commissioning of LT Distribution Box for 63kVA DTR with 100Amp MCCB 3P 16kA for incomer & 100Amp MCCB 3P 16KA 1Nos. And 63Amp MCCB 3P 16KA 2nos. for outgoing circuit.
Supply,Carraige upto site, Installation, testing and Commissioning of Sundry items like Aluminium lugs, Jumpers, Binding tapes etc.
Supply,Carraige upto site, Installation, testing and Commissioning of 185sqmm Single core cable 1.1kV Grade XLPE insulated Stranded conductor FRLS type
Supply,Carraige upto site, Installation, testing and Commissioning of Galvanised Nuts & Bolts
Supply,Carraige upto site, Installation, testing and Commissioning of G.I LT structure mukhi type with shackles
Supply,Carraige upto site, Installation, testing and Commissioning of Earthing of Sub Station --Excavation of earth pit dia 650mm & depth 3000mm, installation of earthing pipe pf 40mm nominal bore & 4mm wall thickness & length 2.5mtr long as per IS 1239. GI strip for neutral earthing of size 25mmX3mm for connection of transformer body, GO set & lightening arrestors as per IS 2629/85, GI nut & bolts refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.
Supply,Carraige upto site, Installation, testing and Commissioning of Galvanised stay set with 50X8mm stay clamp, guy insulator (02nos), anchor plate (200X200X6)mm nut bolts, 02nos turn buckle, 1.8m long, 16mm diameter solid GS stay rod & 7/3, 15mm dia GI stranded wire complete
Supply,Carraige upto site, Installation, testing and Commissioning of Cement bottoming 1:2:4 as per standards 0.5cum / pole
Providing & Painting of Poles with one coat of Red Oxide and two coats of aluminium paint and along with pole marking.
Supply,Carraige upto site, Installation, testing and Commissioning of Danger Plate with clamps
Supply,Carraige upto site, Installation, testing and Commissioning of GI Barbed wire for Anti climbing device
Supply,Carraige upto site, Installation, testing and Commissioning of Anti climbing device with clamps
Supply, Carriage up to site, Installation, of Sign Board (2X2 feet) along with required accessories like clamps, nuts and bolts etc.
M/s KHAN ELECTRICAL WORKS & SUPPLIERS
MIR ELECTRICAL ENGINEERING WORKS
TRUE CONSTRUCTIONS
RATHER EELCTRICAL CONTRACTORS ADN SUPPLIERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .