Tender Value
₹21.8 L
EMD Value
₹50,000
Closing Date
13 Jan 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer PH Division,Kollam
State Plan202425 CWSS TO CHAVARA -PANMANAConstruction of New Electrical room at Raw water pump house Sasthamkotta-Construction of New panel board room at Raw water pump house at Sasthamkotta
2024_KWA_718643_1
25/Re tndr 02/ /15684/2023_5_1_1/1
Open Tender
Civil Works - Water Works
Item Rate
90 days
Pump house, Sashthamcotta
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,760
₹50,000
14 Jan 2025
21 Dec 2024
14 Jan 2025
21 Dec 2024
13 Jan 2025
21 Dec 2024
Amount
Construction of electrical room
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
4.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
OD164632/2023-2024:Fabricating, supplying and providing door frame of size 2.10mx.80m using 10cmx5.0cm rectangular GI tube 18 gauge or nearest size suitable for existing opening and shutter frame using 25 mm GI vertical member and covering the openings of 3/4 portion door by using 1mm thick Aluminium sheet by rivetting or suitable fastening and 1/4 th portion up to the top of the door covered with 25mm square weld mesh welded strongly and painting one coat iron primer and 2 coat enamel paint suitable colour and fitting the door using socket and pin type and inside and outer side locking arrangements as per direction from department officers
OD164657/2023-2024:Fabricating, supplying and fitting MS window of size 1m X 1.3m frame size all round making with GI tube 75mmx50mm and providing GI tube vertical at 200mm c/c and shutter made with 25mm GI square tube sutting the outer frame size and shutter frame opening covered with aluminium plane sheets revetted into the25mm frame including necessary hinges and locking system and priming coat suitable colour enamel painting 2 coats etc as per the direction including all cost of material and labour charges
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Electrical Works Tsunami Raw water pump house
OD114947/2023-2024:Shifting of Starter panel-Charges for disconnecting the cables and dismantling and shifting of existing 100 HP starter panels, MSB panel from pump house to the new building
OD114951/2023-2024:Charges for disconnecting the cables from the transformer cable, motor cables,starter cables and other control cables
OD115710/2023-2024:100kVAR APFC PANEL WITH POWER AND CONTROL CABLING Supply, Fabrication, Installation, Testing and Commissioning of Cubicle type, dust and vermin proof, floor mounted, front operated APFC Panel (100kVAR) made out of 16SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel. The switch board should have a set of suitably rated TPN Aluminium Busbars with the specified current and fault level, insulated with heat shrinkable, colour coded PVC sleeves and supported using DMC/SMC piller or finger type Busbar supports. the design should be as per the standards of the electrical inspectorate. Capacitors (APP Type), Capacitor duty contactors, APFC Relay (8 Stage), LED indication type lamps, CT's, Multifunction meter and 2A Backlite fuses are included in this panel.The scope shoud also include cabling, termination of both power and control cables and also supply and instalation of 630a CT in msb panel INCOMER 200A 4p Isolator - 1 No OUTGOING 40 A 3P MCB - 3 Nos 20A 3P MCB - 3 Nos 16 A 3P MCB - 2 Nos 20kVAR Capacitor Duty Contactor -3 Nos 10 kVAR capacitor duty contactor -3 Nos 5kVAR capacitor duty contactor -2 Nos 20 kVAR APP Capacitor(3 Year Warranty) - 3Nos 10kVAR APP Capacitor(3 Year Warranty) - 3 Nos 5 kVAR APP Capacitor(3 Year Warranty)- 2 Nos
OD115721/2023-2024:LT CABLE LAYING Supplying, laying and clamping of XLPE insulated and PVC sheathed armoured power cable, conductors of best conductivity aluminium 1.1KV grade strictly conforming IS: 1554 (Part I) of following sizes in existing cable tray / trench / clipping directly on wall / ceiling.
OD116034/2023-2024:LT CABLE END TERMINATION Supplying and fixing of compression gland for armoured aluminium/copper conductor cable 1.1kv grade and making end termination suitable for 2/3/3.5/4 core cables of the following sizes as required.
OD115827/2023-2024:Earthing Supply and providing ISI plate earthing as per IS: 3043 with 1200x1200x12mm CI earth plate with out Cu strip extending to the other end of the earth plate and bolt to the plate with minimum 3 nos. of SS bolts, filling earth enhancing mineral compount of approved type around earth plate upto a distance of 15cm. with cover
OD115834/2023-2024:VERTICAL DISTRIBUTION BOARDS - (MODULAR INCOMER) Supply and installation of double cover enclosure of MCB DB IP42/43 for 1phase inclusive of copper/brass bus bar, neutral link and DIN bar suitable for incorporating MCB, isolator etc, flush mount on the wall including cutting holes on wall,making good the damages etc. as required.
OD115846/2023-2024:DB / VDB ACCESSORIES Supply and installation of following accessories / circuit breaker in exisitng VDB / DB and making all connections, dressing up as per Electrical schematic and DB schedule, using suitable terminal sockets, marking ferrules etc complete.
OD115857/2023-2024:WIRING Point wiring
OD115893/2023-2024:FIXTURES Supply Installation, testing and commissioning of the following items including cutting holes for recessed fittings, fixing anchor bolt for fan clamps etc. complete.(supply of lights in client scope)
OD115907/2023-2024:SAFETY EQUIPMENTS
OD115919/2023-2024:OTHER ITEMS Supply and installation of emergency push button
OD115923/2023-2024:OTHER SUPPORTS Supply all materials and Fabrication and erection of supports fabricated out of MS angles C Channel and M S flats of adequate size for erection of panel boards, other necessary equipments etc The supports shall be painted with 2 coats of zinc chromate primer and 2 coats of enamel paint.
OD115944/2023-2024:APPROVAL Preparation of all drawings submitting and getting scheme approval from Electrical Inspectorate, submitting of completion certificate, arranging inspection, getting energisation sanction from Electrical Inspectorate and obtaining permanent power allocation & power connection from KSEBL. (Excluding statutory and sundry charges)
Bidder Name
V S ASSOCIATES
stage.html
html • 0.02 MB
finance_1136424.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .