Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.7 LAccepted-AOC 196 A G ARVINDA SARANI GOURI BARI LANE KOLKATA WEST BENGAL 700004 | KOLKATA | WEST BENGAL | 700004 | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹19.2 L+₹54,000 (2.89%)Rejected-AOC 206 MADHUKALA BHAVAN R K VAIDYA ROAD DADAR MUMBAI MAHARASHTRA 400028 | MUMBAI | MAHARASHTRA | 400028 | 2 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 3 | 3₹20.1 L+₹1.4 L (7.49%)Rejected-AOC | 3 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 4 | 4₹24.1 L+₹5.4 L (28.8%)Rejected-AOC | 4 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹39,000
Closing Date
22 Mar 2021, 6:00 pmClosed
Garrison Engineer
GE I P Fy ISHAPORE, PO NAWABGANJ, DIST 24 PGS N WB-743144
As per tender documents
2020_MES_397877_4
8653/2020-21/E8
Open Tender
Civil Works - Others
Item Rate
90 days
GE I P FY ISHAPORE
Class E Category a(I)
6 documents required · 6 mandatory
₹500
GE I P FY ISHAPORE
₹39,000
Yes
30 Mar 2021
4 Mar 2021
24 Mar 2021
4 Mar 2021
22 Mar 2021
4 Mar 2021
4 Mar 2021 - 11 Mar 2021
Amount
To Carry out Visual Inspection & distress survey and to carry out the Non destructive tests & destrcutive tests and to assess the extent of damages and to conduct sub-soil exploration and prepare detail report & drawings of buildings/strcutures involved and to recommend repair methodology of existing retaining wall/ prepare detail strcutural drawings of new retaining wall of Pond/Aqueducts at Seven Tank Estate at Cossipore all as specified here-in-after (Ref Table-I at Ser Page No 17) consisting of following activities:- Note: Mobilization/demobilization charges for transportation of all men and machineries/equipment for conducting the survey work shall be deemed to be included in the quoted rate of the item and nothing extra shall be paid on this account.
Contd/___item No 1.01 Excavation of trial pit of size 2m x 2m and depth 2.5 m to 3 m (or as per requirement at the time of investigation) from EGL/Road top, collection of distrubed/undisturbed soil sample from the pit and conducting routine lab test on the collected soil samples as per relevent IS Codes, all complete including back filling of pits.-02 Nos
Contd/___item No 1.01 Conducting dyanamic cone penetration test (DCPT) by wet method as per IS 4986-Part-II upto 5 mtr depth from EGL/road top level tentatively @ 10m interval or precisely as per site requirement at the affected stretch of the pond-side road.- (08 Nos x 5 m = 40 mtr)
Contd/___item No 1.01 Detail report & drawings containing the study on following findings and remedial proposal : a. Root cause analysis of the failures ocurred. b. Recommendations on detail remedial measures to be taken for protecting and strengthing of all the pond-side road embankments/retaining walls and also submit recommendations and methodolgy on arresting sinking/errossion of the culvert abutment sinking adjdcent to south tank. c. Proposal for necessary rectification/strengthening work to be adopted for arresting the partial collapse and tilting of the aqueduct-side retaining wall adjacent to officers mess. d. Preparation of costed schedule of rectification/strengthneing/retrofitting work or any other proposed remedial measures to be adopted. e. Getting the entire detail report and drawings vetted and approved from any IIT/Govt. Engineering College as approved by GE and submission of reports in 06 Sets.
To Carry out Visual Inspection and distress survey of entire building/structure and to carry out the Non destructive & destructive tests and to assess the extent of damages and prepare report & detail drawings of damages involved and proposed repair methodology of Building/structures with detail execution drawings of GSF Hospital at Cossipore all as specified here-in-after (Ref Table-I at Ser Page No 17) consisting of following activities:- Note: Mobilization/demobilization charges for transportation of all men and machineries/equipment for conducting the survey work shall be deemed to be included in the quoted rate of the item and nothing extra shall be paid on this account.
Contd/___item No 2.00 Structural audit of GSF Hospital at Cossipore shall include following details/activities :- (a) Brief description of the project and structure. (b) Presenting complete investigation data in the prescribed format including important observations during investigation. (c) Detailed specification in drawings showing all members of building/structure with specific highlight of members which are unsafe. (d) Remedial measures to be taken with brief specification and drawings. (e) The report shall contain sufficient coloured photographs of supercial exploration at site. (f) Design parameters relevant to the facility being proposed. (g) The report shall provide typical use of the model for arriving at the safe design loads on different forms of RCC structure and details on the suitability of different cross sections/grade imporvements schemes if found relevant in the project site. (h) The report shall swell upon various options to make the structural safety with respect to the existing structure.
Contd/___item No 2.00 (j) Complete design of recommended structure including analysis of load carrying capacity using STAAD Pro or any software as approved by GE. (k) The report shall define special problems and concerns that may arise during or after construction. (l) Preparation of draft costed schedule of repair/retrofitting methodology. (m) The surperficial and technical investigation report in six sets and shall be vetted and approved by IIT/ Govt. engineering college as approved by GE.
To Carry out Visual Inspection and distress survey of entire building/structure and to carry out the Non destructive & destructive tests and to assess the extent of damages and prepare report & detail drawings of damages involved and proposed repair methodology of Building/structures with detail execution drawings of OHT at NEW Jheel Road Estate at Cossipore all as specified here-in-after (Ref Table-I at Ser Page No 17) consisting of following activities:- Note: Mobilization/demobilization charges for transportation of all men and machineries/equipment for conducting the survey work shall be deemed to be included in the quoted rate of the item and nothing extra shall be paid on this account.
Contd/___item No 3.00 Detail report & drawings of OHT at NEW Jheel Road Estate at Cossipore containing the study on following findings and remedial proposal : (a) Brief description of the project and structure. (b) Presenting complete investigation data in the prescribed format including important observations during investigation. (c) Detailed specification in drawings showing all members of building/structure with specific highlight of members which are unsafe. (d) Remedial measures to be taken with brief specification and drawings. (e) The report shall contain sufficient coloured photographs of supercial exploration at site. (f) Design parameters relevant to the facility being proposed. (g) The report shall provide typical use of the model for arriving at the safe design loads on different forms of RCC structure and details on the suitability of different cross sections/grade imporvements schemes if found relevant in the project site. (h) The report shall swell upon various options to make the structural safety with respect to the existing structure.
Contd/___item No 3.00 (j) Complete design of recommended structure including analysis of load carrying capacity using STAAD Pro or any software as approved by GE. (k) The report shall define special problems and concerns that may arise during or after construction. (l) Preparation of draft costed schedule of repair/retrofitting methodology. (m) The surperficial and technical investigation report in six sets and shall be vetted and approved by IIT/ Govt. engineering college as approved by GE.
To Carry out Visual Inspection and distress survey of entire building/structure and to carry out the Non destructive/destructive tests and to assess the extent of damages and prepare report & detail drawings of damages involved and proposed repair methodology of Building/structures with detail execution drawings of Khal Brigde at MSF Ishapore all as specified here-in-after (Ref Table-I at Ser Page No 17) consisting of following activities:- Note: Mobilization/demobilization charges for transportation of all men and machineries/equipment for conducting the survey work shall be deemed to be included in the quoted rate of the item and nothing extra shall be paid on this account.
Contd/___item No 4.00 Conducting structural audit of existing Khal Bridge near MSF including following activities: (a) Brief description of the project and structure. (b) Presenting complete investigation data in the prescribed format including important observations during investigation. (c) Detailed specification in drawings showing all members of building/structure with specific highlight of members which are unsafe. (d) Remedial measures to be taken with brief specification and drawings. (e) The report shall contain sufficient coloured photographs of supercial exploration at site. (f) Design parameters relevant to the facility being proposed. (g) The report shall provide typical use of the model for arriving at the safe design loads on different forms of RCC structure and details on the suitability of different cross sections/grade imporvements schemes if found relevant in the project site.
Contd/___item No 4.00 (h) The report shall swell upon various options to make the structural safety with respect to the existing structure. (j) Complete design of recommended structure including analysis of load carrying capacity using STAAD Pro or any software as approved by GE. (k) The report shall define special problems and concerns that may arise during or after construction. (l) Preparation of draft costed schedule of repair/retrofitting methodology. (m) The surperficial and technical investigation report in six sets and shall be vetted and approved by IIT/ Govt. engineering college as approved by GE.
To Carry out Visual Inspection and distress survey of entire building/structure and to carry out the Non destructive & destructive tests and to assess the extent of damages and prepare report & detail drawings of damages involved and proposed repair methodology of Building/structures with detail execution drawings of GSF Blgd Nos 10 & 27 at Cossipore all as specified here-in-after (Ref Table-I at Ser Page No 17) consisting of following activities:- Note: Mobilization/demobilization charges for transportation of all men and machineries/equipment for conducting the survey work shall be deemed to be included in the quoted rate of the item and nothing extra shall be paid on this account.
Contd/___item No 5.00 Structural audit of GSF Blgd Nos 10 & 27 at Cossipore shall include following details/activities :- (a) Brief description of the project and structure. (b) Presenting complete investigation data in the prescribed format including important observations during investigation. (c) Detailed specification in drawings showing all members of building/structure with specific highlight of members which are unsafe. (d) Remedial measures to be taken with brief specification and drawings. (e) The report shall contain sufficient coloured photographs of supercial exploration at site. (f) Design parameters relevant to the facility being proposed. (g) The report shall provide typical use of the model for arriving at the safe design loads on different forms of RCC structure and details on the suitability of different cross sections/grade imporvements schemes if found relevant in the project site. (h) The report shall swell upon various options to make the structural safety with respect to the existing structure.
Contd/___item No 5.00 (j) Complete design of recommended structure including analysis of load carrying capacity using STAAD Pro or any software as approved by GE. (k) The report shall define special problems and concerns that may arise during or after construction. (l) Preparation of draft costed schedule of repair/retrofitting methodology. (m) The surperficial and technical investigation report in six sets and shall be vetted and approved by IIT/ Govt. engineering college as approved by GE.
Epicons Consultants Pvt Ltd
BDS Projects India Pvt. Ltd.
S Ghosh & Associates Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .