Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.8 CrAccepted-AOC BHAGA BAZAR DHOLAI P O BHAGA BAZAR P S DHOLAI DIST CACHAR PIN 788120 | CACHAR | ASSAM | 788120 | ₹10.8 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹10.8 CrRejected-Finance HOSPITAL ROAD NEAR ALIA MADRASSA HOUSE NO 0 CITY TOWN SILCHAR P O SILCHAR P S SILCHAR DISTRICT CACHAR PIN 788005 | CACHAR | ASSAM | 788005 | ₹10.8 Cr | L2 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | DEBOJIT DEB L1 | DEBOPRIYO DEB L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and crosssections as per Technical Specification Clause 302.3.5 | 73,350 | Cum | 191 ₹1.4 Cr | 191 ₹1.4 Cr |
| 2.00 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
(I) Private Land | 9,031.93 | Cum | 260 ₹23.5 L | 260 ₹23.5 L |
| 3.00 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Private Land | 4,941 | Cum | 380 ₹18.8 L | 380 ₹18.8 L |
| 4.00 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Clause 401.
II) For Grading II Material | 3,318.75 | Cum | 2,350 ₹78.0 L | 2,350 ₹78.0 L |
| 5.00 | Providing , laying, spreading and compacting stone aggregates of specified sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with 3 wheels 80-100KN static roller in stages to proper grade and camber, applying and brooming stone screening / binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density as per Technical Specification Clause 405. (3) Grading - III (Screening B). A) By Manual Means- | 1,659.38 | Cum | 3,350 ₹55.6 L | 3,350 ₹55.6 L |
| 6.00 | Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per Technical specification clause 1504 including carriage.
a) including Edge block/Edge restraints | 22,125 | Sqm | 1,165 ₹2.6 Cr | 1,165 ₹2.6 Cr |
| 7.00 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle | 5 | Each | 3,933 ₹19,665 | 3,933 ₹19,665 |
| 8.00 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm circular | 4 | Each | 5,345 ₹21,380 | 5,345 ₹21,380 |
| 9.00 | Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular | 4 | Each | 7,537 ₹30,148 | 7,537 ₹30,148 |
| 10.00 | Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 | 1 | Each | 29,845 ₹29,845 | 29,845 ₹29,845 |
Tender Value
₹10.8 Cr
EMD Value
₹21.6 L
Closing Date
16 Feb 2026, 2:00 pmClosed
CE, PWRD
CE, PWRD
MMPPNA_RIDF_XXXI_25_26_543 Improvement of Road from Lilianpur Khasia Punjee road to Monkush via BT Road under RIDF-XXXI of NABARD for the year 2025-26.
2026_PWD_51108_1
CE/DEV/TB/60/2025-26/76 Dtd- 29.01.2026
Open Tender
Civil Works – Roads
365 days
Lakhipur
Please refer Tender Documents
5 documents required · 5 mandatory
₹20,000
₹21.6 L
Yes
CE, PWRD
26 May 2026
12 Feb 2026
16 Feb 2026
12 Feb 2026
16 Feb 2026
12 Feb 2026
12 Feb 2026 - 16 Feb 2026
12 Feb 2026
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and crosssections as per Technical Specification Clause 302.3.5
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (I) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. Private Land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Clause 401. II) For Grading II Material
Providing , laying, spreading and compacting stone aggregates of specified sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with 3 wheels 80-100KN static roller in stages to proper grade and camber, applying and brooming stone screening / binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density as per Technical Specification Clause 405. (3) Grading - III (Screening B). A) By Manual Means-
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per Technical specification clause 1504 including carriage. a) including Edge block/Edge restraints
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm circular
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work
Kilo Metre Stone (Reinforced cementconcrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Ordinary Kilometer stone (Precast)
Construction of Single opening 1000 mm dia NP3 HPC Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109
Laying 1st class bedding on well compacted sand, moorum as per clause 1105(ii)Granular bedding
Brik masonry work in cement mortar in foundation of wall complete excl. pointing and plastering as per drawing and technical specification clause 1100(in prop. 1:4)
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B)1000mm dia.
Plastering with cement mortar(1:6) 15mm thick on brick work for substructure as per technical specification
Construction of Single Box Cell 5.00 x 5.00 M Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6 [Hand Mixing]
Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203 PCC Grade M 20 Nominial mix (1:2:4)
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. R.C.C grade M 20 For design mix RCC M 20
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing
Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, & 1203 IV) R.C.C.grade M 20
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 Random rubble masonry in case of stone pitching laid with cement mortar (1:5)
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
Construction of Single Box Cell 3.00 x 3.00 M Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6
Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203 PCC Grade M 20 Nominial mix (1:2:4)
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. R.C.C grade M 20 For design mix RCC M 20
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, & 1203 IV) R.C.C.grade M 20
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
Construction of trapezoidal shaped drain Open CC Side Drain Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer : TATA/SAIL/Esser Steel/Jindal steel/Shyam steel/RINL) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Construction of RCC Retaining wall Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 With crushed Stone, P.C.C grade M 15, Nominal mix (1:2.5:5)
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 With Crushed Stone, RCC Grade M 20
Construction of RCC Bridge ( 2 x 12.50 M ) Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.(i) upto 3 m depth
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.(ii) 3 m to 6 m depth
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)
Pile load test on single vertical pile in accordance with IS:2911(Part-IV). a). Initial and Routine load test.
Levelling course for Pile cap
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. B RCC Grade M25 (I) Using Concrete Mixer
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork Without plasticiser, For height upto 5 m R.C.C. grade M 25, Using concrete Mixer
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. B. RCC M-25 a. Height upto 5.0m
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
Construction of precast R.C.C. railing of M 30 grade aggregate size not exceeding 12mm, true to line and grade, tolerance of vertical railing RCC post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm, leveling adequate spacing between vertical poss for expansion, complete as per drawing and technical specifications
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
Drainage Spouts complete as per drawing and Technical specification
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A) Granular material
Boulder apron laid in wire crates (Providing and laying of boulder apron laid in wire crates made with 4mm dia GI wire conforming to IS: 280 & IS:4826 in 100mm x 100mm mesh (weaved diagonally) including 10% extra for laps and joints laid with stone boulders weighting not less than 40Kg each.)
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications. Stone/Boulder
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification
Carrying out sub soil Investigation (SSI) for all types of soil (except boring in rock) up to depth of 30m or refusal (N=100) foe each foundation location as per IRC : 78-2000 and submission of SSI report to the Engineer in -Charge for approval. Preparation & Submission of design calculation & Drawing of Foundation , Sub Structure , super structure as per relevant IRC codes and SSI reports, 2(two) copies each of design & drawing of each bridge to be submitted for approval and 8(eight) coipes after approval of competent authority.
Utility shifting
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.11 MB
Tendernotice_2.pdf
PDF • 8.21 MB
Tendernotice_3.pdf
PDF • 0.60 MB
BOQ_81296.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid