| Sl No | Description | Qty | Unit | sonakshi buildtech pvt ltd L3 | Anu Refrigeration works L1 | ANIL THAKUR L4 | S V V ELECTRO ENGINEERING PVT. LTD. L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR LS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/ PVC conduit including dismantling as required.( Group-B ). | 632 | Point | 444 ₹2,80,608 | 460 ₹2,90,720 | 444 ₹2,80,608 | 394.92 ₹2,49,589.44 Lowest |
| 2.00 | Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S.box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required.Group C. | 400 | Point | 634 ₹2,53,600 | 650 ₹2,60,000 | 644 ₹2,57,600 | 565.44 ₹2,26,176 Lowest |
| 3.00 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. | 30 | Point | 634 ₹19,020 | 690 ₹20,700 | 644 ₹19,320 | 565.44 ₹16,963.2 Lowest |
| 4.00 | Supplying and fixing 3 pin 5 amp ceiling rose on the existing junction box/ wooden block including connections etc. as required. | 486 | Each | 64 ₹31,104 | 30 ₹14,580 Lowest | 63 ₹30,618 | 57.42 ₹27,906.12 |
| 5.00 | Supplying and fixing brass batten/ angle holder including connection etc. as required. | 498 | Each | 114 ₹56,772 | 30 ₹14,940 Lowest | 111 ₹55,278 | 103.36 ₹51,473.28 |
| 6.00 | Supplying and fixing 10 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of single pole in the exiting MCB DB complete with connection testing and commiissioning etc. as required. | 246 | Each | 194 ₹47,724 | 180 ₹44,280 | 197 ₹48,462 | 167.2 ₹41,131.2 Lowest |
| 7.00 | Supplying and fixing 25 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of single pole in the exiting MCB DB complete with connection testing and commiissioning etc. as required. | 300 | Each | 194 ₹58,200 | 180 ₹54,000 | 197 ₹59,100 | 167.2 ₹50,160 Lowest |
| 8.00 | Supplying and fixing 32 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of Double pole in the exiting MCB DB complete with connection testing and commiissioning etc. as required. | 84 | Each | 539 ₹45,276 | 490 ₹41,160 | 495 ₹41,580 | 167.2 ₹14,044.8 Lowest |
| 9.00 | Supplying and fixing 16 way Double Door Single pole and neutral Sheet Steel MCB Distribution bord 240 Volt on surface /recess complete with Tinned copper bus bar , neuteral bus bar earth bar/ Din Bar inter connection power painted including earthing etc as required. ( But without MCB/RCCB/Isolator). | 30 | Each | 2,444 ₹73,320 | 2,351 ₹70,530 | 2,394 ₹71,820 | 2,291.85 ₹68,755.5 Lowest |
| 10.00 | Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | 12 | Each | 4,544 ₹54,528 | 1,850.5 ₹22,206 Lowest | 4,544 ₹54,528 | 1,912.01 ₹22,944.1 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
10 Jun 2022, 11:30 amClosed
Sr. Manager (Contracts)
Procurement- Contract Divison, Tanakpur Power Station, Banbassa , Champawat
Rewiring of 30 Nos of C-Type and 12 Nos D Type Quarters at Tanakpur Power Station
2022_NHPC_687530_1
NH/TPS/PnC/NIT/2022/ E56960/888/24 dt 6/5/22
Open Tender
Civil Works
Works
84 days
NHPC Ltd. Tanakpur Power Station, Banbasa
As per tender document
5 documents required · 5 mandatory
₹1,180
NHPC Ltd. Tanakpur Power Station
₹1.3 L
9 Jul 2022
9 May 2022
14 Jun 2022
9 May 2022
10 Jun 2022
9 May 2022
9 May 2022 - 23 May 2022
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR LS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/ PVC conduit including dismantling as required.( Group-B ).
Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S.box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required.Group C.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing 3 pin 5 amp ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 10 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of single pole in the exiting MCB DB complete with connection testing and commiissioning etc. as required.
Supplying and fixing 25 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of single pole in the exiting MCB DB complete with connection testing and commiissioning etc. as required.
Supplying and fixing 32 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of Double pole in the exiting MCB DB complete with connection testing and commiissioning etc. as required.
Supplying and fixing 16 way Double Door Single pole and neutral Sheet Steel MCB Distribution bord 240 Volt on surface /recess complete with Tinned copper bus bar , neuteral bus bar earth bar/ Din Bar inter connection power painted including earthing etc as required. ( But without MCB/RCCB/Isolator).
Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 8 way (4 + 24), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 100 A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
Providing and fixing 100 A rating and 30KA breaking capacity and four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and fixing 5/6 amps modular switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.
Supplying and fixing 2 way 5/6 amps modular switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.
Supplying and fixing 5/6 amps modular bell push switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.
Supplying and fixing 3 pin 5/6 A modular socket outlet on the existing modular plate & box including connections but excluding moduler plate etc. as required
Supplying and fixing 15/16 A modular swich on the existing modular plate and swich box including connections but excluding modular plate etc.as required.
Supplying and fixing 6 pin 15/16 A modular socket outlet on the existing modular plate and swich box including connections but excluding modular plate etc.as required.
Supplying and fixing two module stepped type electronic fan regulator on tha existing modular plate swich box including connections but excluding modular plate etc.as required
Supplying and Fixing Call bell /Buzzer suitable for single phase 230V. Complete as required.
Supplying and fixing 2 module (75mm+75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 4 module (125mmX75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 6 module (200mmX75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 8 module (125mmX125mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 12 module (200mmX150mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required
Wiring for submain wiring alongwith earth wire with the 2x 2.5 sq. mm+ 1x 2.5 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Wiring for submain wiring alongwith earth wire with the 2 x 4 sq. mm+ 1x4 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Supplying and fixing of 25mm of medium class PVC conduit along with accessories in surface /recess including cutting the wal and making good tha same in case of recessed conduit as required.
Wiring for submain wiring along with earth wire with the 2 x 16 sq. mm + 1x6 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supplying and Fixing single phase, two wire AC energy meter. Range 5-30A
S V V ELECTRO ENGINEERING PVT. LTD.
sonakshi buildtech pvt ltd
ANIL THAKUR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .