Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid |
Tender Value
₹3.0 L
EMD Value
₹5,911
Closing Date
8 Feb 2025, 3:00 pmClosed
Assistant Engineer, PWD Kakdwip Electrical Sub-Div
Office of the Assistant Engineer, PWD Kakdwip Electrical Sub-Division
Urgent Electrical renovation and repair work incl AC installation with allied EI work at Xray room of Kakdwip S D Hospital under Kakdwip Electrical Section II PWD
2025_WBPWD_806861_1
WBPWD/AE/KESD/eNIT02_2nd Call/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
Kakdwip Sub-Divisional Hospital
Please refer tender documents
3 documents required · 3 mandatory
₹5,911
Yes
Office of the Assistant Engineer, PWD Kakdwip Elec
24 Feb 2025
30 Jan 2025
10 Feb 2025
30 Jan 2025
8 Feb 2025
1 Feb 2025
31 Jan 2025
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] (Avg. run 8 mtr.)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire -- Do--Do---- On Board
Supplying and fixing 4-way, up to 160A, double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, with cable-end box at both ends, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of, spiral link, copper wire & neutral link & provision for earthing attachment, as per GS. Incoming 125 A Four pole MCCB-1no, Outgoing 100A TPMCB - 1 No. & 63A TPMCB- 3 no. (Make:Legrand) .
S&F 415 V, Horizontal type, TPN MCB DB (4-way) with SS enclosure double-door with IP-42/43 protection, with cable-end box at both ends & Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 KA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Interconnection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. Incoming 63 A FP Isolator -1 No, Outgoing 6-32A SPMCB-12 no. (Make:Legrand) .
Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2x356/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm)
Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 40mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [VTPN SFU to HTPN]
S&F compression type gland complete with brass gland, brass ring & rubber ring for dust & and moisture-proof entry of existing 4Cx35sqmm XLPE/PVC armoured cable, as per GS.
S/F Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket for existing 4 core 35sqmm XLPE-armoured AL. cable(Dowels make), tapes, anticorrosive paste & jointing materials :as per GS.
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [PWD/GS Page: F-5 Item: 9]
4x126/0.4 (16 sqmm) single core Cu wire
2x356/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm)
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire [ for Ac connection]
Supply & Fixing 240 V, 25 A, Modular type starter (NorthWest) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc [ for Ac connection ]
Supply and drawing 1.1 KV grade 4x16sq.mm single core PVC insulated & unsheathed copper wire in 25mm. dia PVC Rigid Conduit [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works as directed by EIC. [Make-Finolex/Havells/Polycab/Gloster]
S&F of 250V double door Timer DB [equivalent of 2+8 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DPMCB ('C' curve 10KA), 2 no. 16A SPMCB ('C' curve 10KA), 1no. Programmable time switch-24 hrs with minimum switching of 15 minutes and 1 no. 18A/25A 2-Pole power contractor with inner-outer plate & internal wiring by suitable size of cu. wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running condition with mechanical locking arrangement, as directed by EIC. [Make-ABB/L&T/Crabtree]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: a) By TATA Medium GI Pipe
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil)
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. as direction fo EIC.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Supply & Delivery of Non-inverter type High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 6.6 kW (Minimum) , Capacity : 1.8TR or Above Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2024] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply -230V, 50Hz (±tolerance asper applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) [Make: O General/Mitsubishi Electric/Zamils]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including Supply of required Refrigerant, S&F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm MS angle iron frame for outdoor unit (or arrangement recomended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast)
Supply and delivery of Twin LED Fitting (20Watt, 230VAC, 50hZ, 4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 2 nos LED Tube, as directed by EIC. [Make: Philips TMC 501 P 2xT-LED, Havells, Bajaj, CG, or as per EIC]
Fixing only above single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length, as per GS.
Supply & delivery of 1400 mm sweep 230 volt AC Ceiling fan incl. Blades, canopy etc. With 18" down rod(14SWG), Fork(10SWG), Heavy type insulator, 3/8th inch bolt with nut, heavy type split pin etc., as directed by EIC [Make-Orient /Crompton/Usha] incl . safety wire & P2 type brust proof capacitor.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per direction of EIC.
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .