| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 14 5 TRIPUNITHURA KOTTAPARAMBIL BUILDINGS KOLLANPADY VILLAGE TOWN THIRUVANKULAM CITY TRIPUNITHURA ERNAKULAM KERALA 682309 INDIA | ERNAKULAM | KERALA | 682309 | Admitted-Finance |
| 2 | Admitted-Finance 33 656 C1 C2 ARAKKAKADAVU ROAD THAIKKAVU JUNCTION VENNALA P O KOCHI ERNAKULAM KERALA 682028 | ERNAKULAM | KERALA | 682028 | Admitted-Finance |
| 3 | Admitted-Finance 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹65,000
Closing Date
27 Dec 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SM(MAT)-C
CONTRACTS MATERIALS DEPARTMENT FACT UDYOGMONDAL DIVISION
Integration of existing field instruments of 5000MT Ammonia tank to new control room at FACT CD, Ambalamedu,
2022_FACT_724543_1
04028/2022-2023/E26367
Open Tender
Miscellaneous Works
Item Rate
FACT COCHIN DIVISION
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹65,000
Yes
20 Jan 2023
21 Nov 2022
27 Dec 2022
21 Nov 2022
27 Dec 2022
21 Nov 2022
Fabrication of ladder type cable racks of size 800mm using 65x65x6mm Aluminium angles and their erection in pipe racks of 5000MT Ammonia Handling Site-B as per Drg No. INST/AHSB/CR-001. Aluminium angles of size 65x65x6mm shall be used as cross bars and shall be provided at intervals of 500mm by drilling two numbers of holes at each end and fixing it with fasteners [SS304-nut, bolt and washers of size 60 x 8 mm]. Fixing of the rack from the New control room to the existing pipe rack near to 5000MT tank shall be on proper MS angle support. The locations of the cable tray is indicated as MCR 1 in drawing no INST/AHSB/CR-001. The work shall include painting of MS supports with one coat of epoxy-based primer and two coats of epoxy paint of dark grey colour. The MS/Aluminium angles shall be supplied by FACT. SS fastners, primer, paint shall be in the scope of contractor
Fabrication of ladder type cable racks of size 500mm/300mm/200mm/100mm using Aluminium angles of size 50x50x6mm and Aluminium flats of size 50x8mm. The erection in wall/ supports in the 5000MT Ammonia Handling Site-B and premises is as per TSD Drg Nos. INST/AHSB/CR-001, INST/AHSB/CR-002. Aluminium flat cable supports shall be provided as cross bar at intervals of 500mm by drilling two numbers of holes at each end and fixing it with fasteners [SS304- nut, bolt and washers of size 40 x 6 mm]. The fixing of the fabricated rack shall be by using proper MS angle support or using proper SS304 anchor bolts. SS nut, bolt and washers of size 60 x 8 mm shall be used wherever required for the erection of the cable racks. The locations of the cable trays are indicated in series MCR 2, MCR 3, MCR 4, MCR 5, MCR 6, MCR 7, MCR 8, MCR 9, MCR 10 and BCR 1 to BCR 29 in drawing nos. INST/AHSB/CR-001, INST/AHSB/CR-002. The work shall include painting of MS supports with one coat of epoxy-based primer and two coats of epoxy paint of dark grey colour. Breaking of walls, sunshade etc. to carry out the work comes under the scope of the contractor. The MS/Aluminium angles, flats shall be supplied by FACT. SS fastners, SS anchor bolts, primer, paint shall be in the scope of contractor
Installation of signal cables-20pair with wires of size 0.5/1 SQMM by laying in new/ existing cable rack / clamping on the wall / structure / routing through GI pipe. The cables are to be laid from control room to different junction boxes. Dressing of cables in racks shall be by using Al strips of size 20x5mm at intervals of 1 meter. Clamping of cables on structure shall be by welding and fixing suitable cleats. The cables shall be supplied by FACT. Aluminium strips, cleats shall be in the scope of contractor.
Installation of power cables-12 pair with wires of size 1/1.5 SQMM by laying in new/existing cable rack / clamping on the wall / structure / routing through GI pipe. The cables are to be laid from control room to different junction boxes. Dressing of cables in racks shall be by using Al strips of size 20x5mm at intervals of 1 meter. Clamping of cables on structure shall be by welding and fixing suitable cleats. The cables shall be supplied by FACT. Aluminium strips, cleats shall be in the scope of contractor.
Installation of signal/ power cables-1 pair, 2 pair and 1 triad with wires of size 0.5/1/1.5 SQMM by laying in new/existing cable rack / clamping on the wall / structure / routing through GI pipe. The cables are to be laid from junction boxes to field instruments. Dressing of cables in racks shall be by using Al strips of size 20x5mm at intervals of 1 meter. The cables shall be supplied by FACT. Aluminium strips, Clamps shall be in the scope of contractor.
Glanding of the signal and power cables of size 20Pair and 12P at junction boxes / Marshalling Panel using double compression / single compression glands of size 1.25inch and 1.5inch. The glanding shall be done with good workmanship and securing of glands shall be proper and tight. Stripping of insulations from wires shall be done without nicking the conductor. Standard stripping tools of proper design shall be used for carrying out the work. Double Compression glands shall be used in field and single compression glands to be used inside control room. SS Cable glands shall be in the scope of contractor
Glanding of the signal and power cables of size 20Pair and 12P at Marshalling Panel using single compression glands of size 1.25inch and 1.5inch. The glanding shall be done with good workmanship and securing of glands shall be proper and tight. Stripping of insulations from wires shall be done without nicking the conductor. Standard stripping tools of proper design shall be used for carrying out the work. SS304 cable glands shall be in the scope of contractor
Glanding of the signal and power cables of size 1 Pair / 1 Triad / 2 pair at junction boxes/field panels and field instruments using double compression glands of size 0.5inch. The glanding shall be done with good workmanship and securing of glands shall be proper and tight. Stripping of insulations from wires shall be done without nicking the conductor. Standard stripping tools of proper design shall be used for carrying out the work. SS Cable glands shall be in the scope of contractor
Termination of individual wires size 0.5/1/1.5 sqmm of 20pair/ 12 pair/ 2 Pair/ 1 Pair/ 1 Triad cables at terminal strips and field instruments. The work shall include, removal of outer sheath, insertion of printed ferrules, crimping lugs on to individual cores, earthing of shield wire, and connecting the cable at the terminal strip/ field instruments with proper dressing. All wires or leads terminated at connection shall have sufficient slack. Screws shall be torqued adequately to get good contact with wires inserted under the screw. Stripping of insulations from wires shall be done without nicking the conductor. Standard stripping tools of proper design shall be used. The unused wires in the cables shall be tied properly with cable ties & supports and kept neatly inside the junction box. Cross ferruling shall be followed. The printed ferrules, tinned copper bootlace lugs, cable ties shall be in the scope of contractor.
Installation of Junction Boxes of size 350x420x150mm approx. on newly fabricated AL / MS Supports. The work shall include the fabrication of MS/ aluminium supports with necessary holes drilled for mounting the JBs and fixing it on to the available structures by wielding/ using fasteners (SS 304 bolt, nut and washers) or grouting on to the structure. The Junction box shall be mounted to the newly fabricated MS supports by using SS nut, bolt and washers of proper size. Vacant gland holes in the JBs shall be covered with proper blanking plugs. MS supports shall be painted with one coat of epoxy based primer and two coat epoxy paint of dark grey colour. The work also includes minor civil work required for fixing JBs. The junction boxes, Aluminium/MS angles shall be supplied by FACT. The SS fastners, blanking plugs, primer , paint shall be in the scope of contractor.
Fabrication and erection of Pedestals/ Stanchions for mounting field instruments upto 4 numbers. The Pedestals/ Stanchions shall be fabricated using base plate and 2" SS pipe of height 1500mm. Pedestal/ Support installed on a pavement; shall be fixed to the concrete paving with anchor bolts. If ground is un-paved, a concrete base shall be provided for the pedestal. Pedestals/ Support mounted on top of platforms shall be removable. Stanchions shall be fixed by welding/ grouting to the existing structures. Proper supports of MS Angles/ Flats shall be fixed on the pedestal/ stanchion by welding if necessary. Pedestals/ Stanchion/ Supports/ shall be painted with one coat epoxy based primer and two coat epoxy paint of dark grey colour. The SS pipe, MS angles shall be supplied by FACT. SS anchor bolts, concrete, primer, paint shall be in the scope of contractor
Fabrication and erection of "L" shape support for mounting field instruments. The support (300X 200mm approx.) shall be fabricated using 2" SS pipe. The support shall be fixed on to concrete beams using baseplate and anchor bolts or to be welded on to existing structures. Supports shall be painted with one coat epoxy based primer and two coat epoxy paint of dark grey colour. SS pipes shall be supplied by FACT. SS anchor bolts, primer, paint shall be in the scope of contractor.
Fixing of FRP canopies of size 360 X 445 X 370mm or 550X 450X 325mm (W X D X H) for field instruments and junction boxes on existing/ newly fabricated structures. The canopies shall be secured using mounting brackets/ U clamps and SS304 nut bolt & washers. The FRP canopies and mounting brackets/U clamps shall be supplied by FACT. SS fastners shall be in the scope of contractor.
Installation/ mounting of the transmitters inside the FRP enclosures / canopies on Stanchions/Pipe Supports/ Structurals with suitable SS mounting brackets/ SS U clamps, SS identification tags and SS304 nut bolt & washers. The transmitters, mounting brackets/u clamps shall be supplied by FACT. The identification tags, SS fastners shall be in the scope of contractor.
Laying of 6mm/ 8mm/ 10mm SS304 pneumatic tubing from Air headers in the field to the Air Filter regulator and I/P converter etc. of control valves. The tubing will involve providing standard SS fittings from air header to control valve accessories as required. Ends shall be connected at air header tapings, air filter regulator or I/P Converter. Sharp bends shall be avoided and proper support shall be given using clamps for the pneumatic tubing. Tubes shall be cut using only the standard cutter. Use only fines and-paper for polishing the outer edge of the tubes after cutting. Never use a file or grinder for cutting and polishing tubes. Proper support shall be provided using aluminium clamps for the tubing. The SS tubes, tube fittings shall be supplied by FACT.
PROFICIENT AUTOMATION AND CONTROLS PRIVATE LIMITED
Dinu Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .