Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-Finance | L1 | Accepted-Finance Being the L1 bidder | |
| 2 | L2₹4.1 L+₹6,945 (1.70%)Rejected-Finance | L2 | Rejected-Finance Being the L2 bidder |
Tender Value
₹4.2 L
EMD Value
₹8,454
Closing Date
4 Nov 2024, 3:00 pmClosed
Nodal Officer (Tender)
O/o CE (C) BSNL Civil Odisha Zone , Bhubaneswar
Repair to roof leakage of IQ and exchange area portion only of Door Sanchar Bhawan Building at Rourkela under BSNL SSA Rourkela
2024_BSNL_212491_1
32/CE(C)/2024-25/BCD/SBP
Open Tender
Civil Works
Item Rate
60 days
Rourkella
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Accounts Officer (Cash) BSNL O/o GMTD Sambalpur
₹8,454
Yes
17 Dec 2024
25 Oct 2024
5 Nov 2024
25 Oct 2024
4 Nov 2024
25 Oct 2024
Amount
Sub-Head : Concrete Work
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
Sub-Head : Roofing
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
In 75x75 mm deep chase
Making Khurras 45X45cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm mnominal size ), finished with 12 mm cement palster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement rounding the edges and making and finishing the outlet complete including dismantaling existing Khurra and disposal of the unserviciable material upto lead of 50 Metre
Sub-Head : Dismantling and Demolishing
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Sub-Head : Water Proofing
Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Cement mortar 1:4 (1cement : 4 coarse sand)
Sub-Head : Repairs to Buildings
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
With cement mortar 1:4 (1cement: 4 coarse sand).
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
3 mm thick
Sub-Head : MARKET RATED ITEMS
Dismantling , removing and cleaning old /damged tarfelt i/c scrapping from wall/colmn/roof surace and disposal the same as per direction EIC.
Repairing to the leakage from damaged/rusting old GI pipe inside the wall cutting the wall and replacing with new PVC pipe with fitting and making the damaged surface same as per direction of E.I.C (cost of PVC pipe and fittings will be paid separately)
Repairing to the leakage from damaged old GI pipe/PVC pipe exposed on wall face and near water tank by replacing with new PVC pipe with fittings and making the damaged surface same as per direction of EIC (cost of PVC pipe and fittings will be paid separately)
GIRIJA SHANKAR MISHRA (BID ID -762909)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .