Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹6.8 L | L1 | Accepted-AOC aoc |
| 2 | L2₹6.9 L+₹15,000 (2.22%)Rejected-Finance FIRST FLOOR 44 DDA SHOPPING COMPLEX BUDH BAZAR SIDE 42 KALKAJI NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | ₹6.9 L+₹15,000 (2.22%) | L2 | Rejected-Finance L1 BEING ACCEPTED |
| 3 | L3₹8.4 L+₹1.6 L (24.4%)Rejected-Finance NO 1073 K R SQUARE 15TH CROSS 30TH MAIN BANASHANKARI 2ND STAGE BANGALORE KARNATAKA 560070 | BENGALURU URBAN | KARNATAKA | 560070 | ₹8.4 L+₹1.6 L (24.4%) | L3 | Rejected-Finance L1 BEING ACCEPTED |
| 4 | L4₹14.6 L+₹7.8 L (116.3%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | ₹14.6 L+₹7.8 L (116.3%) | L4 | Rejected-Finance L1 BEING ACCEPTED |
| 5 | Rejected-Technical | - | - | Rejected-Technical Documents submitted are incomplete and not meeting criteria. |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
10 Sept 2020, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
CONSULTACNCY FOR PROVN OF EARTHING AND LIGHTING ARRESTOR FOR AFNET EQPT AT VAYU VIHAR AND COMMAND BLDG AT HQ SAC U AF TRIVANDRUM
2020_MES_352899_2
CWE(AF)/TVM/82308
Open Tender
Civil Works
Lump-sum
90 days
Trivandrum
As per NIT
7 documents required · 7 mandatory
₹500
GE AF Trivandrum
₹20,000
Yes
23 Oct 2020
19 Aug 2020
12 Sept 2020
19 Aug 2020
10 Sept 2020
27 Aug 2020
19 Aug 2020 - 24 Aug 2020
Amount
SCHEDULE 'A'
(I) A comprehensive health assessment, adequacy and design of lightning protection and earthing systems should be carried out at 8 locations under GE (AF) Trivandrum to ensure effectiveness of the respective systems and protect human being and assets. The general approach should include the following :- (a) Health assessment study of existing lightning protection and earthing systems which will include all necessary tests & measurements as detailed in scope of work. b) Checking adequacy of existing lightning protection and earthing systems (c) Gap analysis and design of lightning protection and earthing systems to meet standards and site requirement and application. (d) Effectiveness of entire grounding system such as measurement of earth electrode resistance - invididual & overall grid, soil resistivity, riser integrity, grid integrity, effect of corrosion, loop impedance and prospective fault current. (e) Carrying out soil investigation to assess the various parameters of the strata/various type of equipment and installed machineries to finalise the type, system, composition and quantity of materials and chemicals required to achieve the earth resistance value less than one Ohm in all climate continuously at least for 10 years in the following locations. The details of soil examinations the results, protocol, and the obtained values in tabulated form along with the clear technical specification of each type of earthing suits to different location mention here before to achieve and maintain the desired results continuously for a period of not less than 10 Years. The bidder has to clearly to mention three to four makes of the different components of the system conventional, chemical or any new version of the earthing system.
(f) In case the recommendation is only for one particular brand (proprietory item) a certificate of undertaking duly authenticated from the firm should also be submitted alongwith the recommendation and the test results. The rate quoted for the above shall include required number of site visits of the Engineers/technical expert of the firm during the investigation and at the time of execution by the same firm or by any other agency to ensure the quality of workmanship so as not to leave any chance for dispute over the chemical materials or the workmanship. The required number of earth pits and confirguration of the pits within the space available/allotted for earthing along with coloured drawing shall also submit with the report. The report submitted shall not share/published to any other agency and all the details must be treated as confidential. The rate quoted shall unclude to provide the required instruments tools,eq-uipments and manpower for excavation/diiging and making good the area after concluding the investigation by the firm. Locations:- (a) SATCOM Building (b) DCN Building (c) HQ SAC Main Building (d) HQ CWE Building (e) New Armoury Building (f) AFNET Vayuvihar (g) HQ SAC Unit (h) WCDMA Area, Vayuvihar.
Total of Schedule 'A'
Unex Power Point Pvt.Ltd
JEF Techno Solutions Private Limited
JEETH CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .