Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC Lowest reasonable tenderer | |
| 2 | L2₹7.9 L+₹6,107 (0.78%)Rejected-Finance GANDHI CHOWK SHIV MANDIR MARG RANIKHET DISTT ALMORA UTTARAKHAND | L2 | Rejected-Finance Not Lowest tenderer | |
| 3 | L3₹9.1 L+₹1.2 L (15.5%)Rejected-Finance | L3 | Rejected-Finance Not Lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
1 Sept 2021, 6:00 pmClosed
GE Ranikhet
GE Ranikhet
CERTAIN REPAIR ELECT WIRING IN MD AND OTM ACCN AT HALDWANI, RANIBAGH AND KAMOLA UNDER GE RANIKHET
2021_MES_464529_1
GE/RKT/ 37 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Haldwani under GE Ranikhet
Class E cat b (i)
7 documents required · 7 mandatory
₹500
Yes
GE Ranikhet
₹16,000
Yes
5 Oct 2021
2 Aug 2021
3 Sept 2021
2 Aug 2021
1 Sept 2021
16 Aug 2021
Amount
BOQ ( Sch 'A') E/M WORKS Taking down carefully aluminium/copper wiring of any size (for light, fan, socket or power etc complete) ( fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed.
Supply & Fixing point wiring for one light point/ fan/ bell (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia ) with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface) and sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge.
All as per item No.2 herein before but one light point controlled by two switches
All as per item No. 3 herein before but one socket outlet 5 amps one switch on same board with other switchs.
All as per item No.2 herein before One socket outlet 5 amps controlled by one switch on independent board.
All as per item No 2 herein before but wiring with 2.5sqmm copper wire (FRLS) PVC and 1.5 sqmm earth wire for socket outlet 5 pin 15 amps on independent board.
Supply & Fixing point wiring for one light point/ fan/ bell (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including PVC casing/capping and accessories including sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge.
All as per item No.7 herein before but light point controlled by two way switch
All as per item No.7 herein before but one socket outlet 5 amps on same board.
All as per item No. 8 herein before One socket outlet 5 amps on independent board.
All as per item No 7 herein before but wiring with 2.5sqmm copper wire (FRLS) PVC and 2.5 sqmm earth wire for socket outlet 5 pin 15 amps on independent board.
Suppy & Fixing switch piano flush type single pole, one way 6 Amp complete all as specified and directed.
Suppy & Fixing switch piano flush type single pole, two way 6 Amp complete all as specified and directed.
Suppy & Fixing switch piano flush type single pole, one way 16 Amp complete all as specified and directed.
Supply & Fixing socket out let 2 in1,3 pin, 6 Amp, flush type complete all as specified and directed.
Supply & Fixing socket out let 2 in1,3 pin, 6 and 16 Amp, flush type complete all as specified and directed.
Supply & Fixing ceiling rose, PVC/ Poly carbonate, isolated body three terminal complete all as specified and directed.
supply & Fixing lamp holder (Dome type) PVC insulated body with back plate for angle/battern fitting complete all as specified and directed
Supply and fixing Bell push , flush type 5 amp complete all as specified and directed.
Supply and fixing Buzzers and Bell AC 230 volts, 50 Hz single pole complete all as specified and directed.
Supply and fixing steped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed.
Supply and fixing white cover plate with frame 2 module on existing boxes complete all as specified and directed.
Supply and fixing white cover plate with frame 3 module on existing boxes complete all as specified and directed.
Supply and fixing white cover plate with frame 4 module on existing boxes complete all as specified and directed.
Supply and fixing white cover plate with frame 6 module on existing boxes complete all as specified and directed.
Supply and fixing white cover plate with frame 8 module on existing boxes complete all as specified and directed.
Supply and fixing Modular Switch1 way 6 Amp, 1 module complete all as specified and directed.
Supply and fixing Modular Switch 2 way 6 Amp, 1 module complete all as specified and directed.
Supply and Fixing Modular fan step regulator, 120 W- 2 Module complete all as specified and directed.
Supply and fixing Modular Switch1 way 16 Amp, 1 module complete all as specified and directed.
Supply and fixing Modular socket shuttered, 6 Amp, 2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing Modular socket , 6/16 Amp, 2/3 pin combined 2 module complete all as specified and directed.
Supply & Fixing modular bell push 6 amp I module complete all as specified and directed .
Supply and fixing anodised rust proof 18 SWG MS box, flush type of size 75x105x50 mm deep 1-2 Module (to be of same make as modular switches and sockets) to be recessed in wall /gypsum partition complete all as specified and directed.
All as per item No 34 here in before but of size 75x105x50 mm deep 3 Module
All as per item No 34 here in before but of size 75x105x50 mm deep 4 Module
All as per item No 34 here in before but of size 75x105x50 mm deep 6-8 Module
Supply & Fixing in repaiirs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of size 100x100x50mm deep fixed with screws and washers including taking down unserviceable switch board of any make/ type and making good the disturbed surfaces to match with existing surface complete all as specified and directed.
All as per item No 38 here in before but 175x100x50mm deep
All as per item No 38 here in before but 200x150x50mm deep
All as per item No 38 here in before but 250x200x50mm deep
Supply & Fixing in repair 240 V, 10 KA 'B' curve miniature circiut breaker ( MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply & Fixing in repair 240 V, 10 KA 'C' curve miniature circiut breaker ( MCB) of single poles neutral ( SPN) and current carrying capacity 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supplied & Fixing Rigid non matallic PVC conduits external dia 20 mm ISI marked exclusive of boxes (Junction/terminal) but inclusive of all tee, bends, elbows, reducers, bell mounth tube ends and fixing accessories such as couplers, lock, nuts, saddles, pipe hooks etc for exiting point/main/sub-main wiring complete all as specified and directed.
Supply & Fixing sheet metal enclosure for DBs (double door type) single pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 240 volts including taking down underviceable main switches MCB DB's of any make and type , teak board etc and making good the disturbed surfaces to match with the existing surface complete all as specified and directed .
Supply & Fixing sheet metal enclosure for DBs(double door type) single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts including taking down underviceable main switches MCB DB's of any make and type , teak board etc and making good the disturbed surfaces to match with the existing surface complete all as specified and directed .
Supply & Fixing sheet metal enclosure for DBs(double door type) single pole and neutral 12 way including blanking plate as required with 200 Amps rated bus bar, 240 volts including taking down underviceable main switches MCB DB's of any make and type , teak board etc and making good the disturbed surfaces to match with the existing surface complete all as specified and directed .
Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed concealed with and including 4Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoated rates. 2. (2+1)Three run of 4 sqmm, and one run of PVC conduit will be measured as one unit ie one running metre”
Material and labour for Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed concealed with and including 6.0Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoated rates. 2. (2+1) Three run of 6 sqmm and one run of PVC conduit will be measured as one unit ie one running metre”
Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
S & F LED light fitting 1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed . Make : Havells cat pat HEXAFT10WLED857SSYMBOPC or equivalent cat part in make specified in particular specification Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supply and fixing LED lights T-5 fitting 1x 20W (warm/milky white as required on site), 220V, AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose 1.5 RM and life of tube light not less than 50,000 hours complete all as specified and directed. Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supply and fixing LED lights T-8 fitting 1x 20W (warm/milky white as required on site), 220V including LED tube light connecting up with two core flexible copper conductor cable of suitable size from ceiling rose 1.5 RM and life of tube light not less than 50,000 hours complete all as specified and directed.. Note:- Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supply and fixing LED mirror light (T-5) fitting with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible opper conductor cable of suitable size complete all as specified and directed.
Material & labour for taking down ceiling fans / wall mounted fans of any size / sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, taking out burnt/damaged winding, bushes & cleanig of stator and rotor incl etc. Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing /bushes, condencer 2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter in length and make the fan operational with a guarantee period of one year after installing the repair fan complete all as specified and directed.
Material & Labour for taking out burnt/damaged winding, bushes & cleanig of rotor etc of exhaust fans any sweep, Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing /bushes, handing and testing of fan with and including provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter in length complete all as specified and directed
Supply and fixing solar heater tube suitable for fixing of solar water heater system ( Executed tube collector based) on direct transferring of heat of capacity 500 LPD and make the system operational complete all as specified and directed.
Material & labour Servicing of indoor and outdoor unit of split type AC of 1.5/2.0/3.0 ton capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifing water leak, checking and tightning the electrical connection complete all as specified and directed
Supply and Refilling Gas/ refrigerant ( CFC free) in AC 1.5 ton , 2 Ton complete all as specified and directed.
Supply and Refilling Gas/ refrigerant in Refrigerator having capacity 65 to 315 ltrcomplete all as specified and directed.
Supply and Refilling Gas charging in Water cooler of capacity 60/120 litre complete all as specified and directed.
Supply, fixing and commissioning of Compressor for Split and window, 1.5 ton AC complete all as specified and directed.
Supply, fixing and commissioning of Compressor Split and window, 2 ton complete all as specified and directed.
Supply, fixing and commissioning Refrigerator compressor of capacity 65 to 180 ltr complete all as specified and directed.
Supply, fixing and commissioning Refrigerator compressor of capacity 210 to 315 ltrs complete all as specified and directed.
Supply, fixing and commissioning water cooler compressor of capacity 40/80 ltrs complete all as specified and directed.
Supply, fixing and commissioning water cooler compressor of capacity 60/120 ltrs complete all as specified and directed.
Supply, fixing and commissioning of relay for split and window AC capacity upto 2 Ton complete all as specified and directed .
Supply, fixing and commissioning of relay for Refrigerator upto 315 Ltr capacity complete all as specified and directed.
Supply, fixing and commissioning of PCB for split/window AC upto 2 ton capacity complete all as specified and directed.
Supply, fixing and commissionin Condenser 50 mfd for split/window AC upto 2 ton capacity complete all as specified and directed.
Supply and fixing Thermostat of split/window AC of any capacity complete all as specified and directed.
Supply and fixing Thermostat of Refrigerator any capacity complete all as specified and directed.
Supply and fixing Thermostat of Water cooler of any capacity complete all as specified and directed.
Supply and fixing Water cooler PVC pipe complete all as specified and directed.
Supply and fixing blead with motor Split/ window AC of capacity 1.5 TR to 2 TR complete all as specified and directed.
Supply and fixing timer switch for refrigerator of any capacity complete all as specified and directed.
Supply and fixing remote unit for split type AC of any model/size complete all as specified and directed.
Supply and fixing motor Fan motor Water cooler of capacity 60/120 ltrs complete all as specified and directed.
Supply and fixing Revarse valve of AC/Refrigerator /water cooler. complete all as specified and directed.
Supply and fixing swing motor for split AC of any capacity complete all as specified and directed.
Supply and fixing cooling coil for Window / split AC of any capacity and size complete all as specified and directed.
Supply and fixing Electronic control PCB for refrigerator upto 315 Ltr capacity complete all as specified and directed.
Supply and fixing Float valve 15mm for water cooler 40to 120ltr capacity complete all as specified and directed.
Supply and fixing Push tap for water cooler any size/ capacity complete all as specified and directed.
Material and labour for repair of voltage stablizer of capacity 4/2/1 KVA, single phase, 230V AC, 50 Hz complete all as specified and directed.
Supply and fixing heating coil / condenser coil for split / window AC 1.5 TR to 2 TR complete all as specified and directed.
Material & labour for taking out burnt/damaged winding, bushes & cleaning of rotor etc of Desert cooler, Rewinding with 26/27 SWG of enameled copper winding wire replacement of bearing / bushes, handing and testing of fan with and including provision of 23/0.0076 copper flexible core twin core not less than 3 meter in length and make the desert cooler in operational condition complete all as specified and directed including comprising of the following works :- (i) Replacement of water pump including water pipe (Complete set). (ii) Replacement of Fan bleed (PVC/Iron) as required on site. (iii) Replacement of desert cooler front grill (Fiber/Steel/Plastic as required) including switch, indicator and regulators. (iv) Checking & tightening the electrical connection (v) Replacement of wood wool (Grass Air cooler cooling pad) suitable of iron/Plastic body desert cooler (vi) Replacement of side grill (sets of 3) for holding wood wool/cooling pads.
Material & labour for servicing of water heater (Geyser) upto 50 Ltr capacity of any make by cleaning sludge and slurry, calcium inside inner water storage tank and make the geyser in operational condition all as specified and directed by Engr-in-charge including comprising of the following works :- (i) Rectifying water leakage in inner copper/iron storage tank by using welding (ii) Replacement of heating element upto 2000 Watt. (iii) Replacement of Thermostat of suitable size as required on site. (iv) Checking & tightening the electrical connection (v) Replacement of safety valve. (vi) Replacement of NRV (Non returning valve) of suitable size as required at site .
M/S NAYAL ELECTRICALS
AJA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .