CE NW Kochi
Kataribagh, Naval Base,Kochi-04
DEMOLITION OF OLD OFFICE COMPLEX AND RECONSTRUCTION IN MULTI-STORIED CONFIGURATION AT MO(K) NAVAL BASE KOCHI
2022_MES_499600_1
890979
Open Tender
Civil Works
900 days
Kochi
As per NIT
8 documents required · 8 mandatory
₹3,000
GE (P) NW Kochi
₹15 L
Yes
24 Mar 2022
5 Jan 2022
5 Mar 2022
5 Jan 2022
2 Mar 2022
23 Feb 2022
6 Jan 2022 - 29 Jan 2022
Amount
LIST OF WORKS
Schedule A Part I to Part XIII)
Total amount of Sch 'A' Part-I (Buildings & Structures)
Total amount of Sch 'A' Part-II ( Excavation, Earth work and Site clearence)
Total amount of Sch 'A' Part-III (Internal Electric Supply)
Total amount of Sch 'A' Part-IV (Internal Water Supply)
Total amount of Sch 'A' Part-V (Road/Path/Hardstanding)
Total amount of Sch 'A' Part-VI(Sewage Disposal)
Total amount of Sch 'A' part-VII (Area Drainage)
Total amount of Sch 'A' part-VIII (External Water supply)
Total amount of Sch 'A' part-IX (External Electric Supply)
Total amount of Sch 'A' part-X ( Lightning Protection)
Total amount of Sch 'A' part-XI(Fire Detection & Fire alarm Systems)
Total amount of Sch 'A' part-XII(Standby DG Set)
Sch 'A' Part- XIII(MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Boring for cast-in-situ under reamed piles of 500mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 600mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 700mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 900mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Material and labour for RCC with ready mix concrete(RMC) M30 grade in cast in situ bored pile with minimum cement content 400kg/cum of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV. Note:-(i) Reinforcement will be measured and paid separately under relevant items
Material and labour for RCC with ready mix concrete(RMC) M30 grade in pile cap , grade beam & tie beam complete all as specified and shown on drawing. Note:-(i) Reinforcement will be measured and paid separately under relevant items
Material and labour for TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for bored piles of any length and any dia all as shown on drawings including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Material and labour for TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over for grade beam/tie beams and pile caps of any length and any dia all as shown on deawings including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
Material and labour for TMT bars (CRS/HCRM/CRM) in reinforcement 5mm dia and over up to and including 12mm dia as in stirups for pile caps and gared beams including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs.
All as per item No 24 above but 5mm dia and over up to & including 12 mm dia as in helicals of pile reinforcement including rings and necessary tack welding to pile reinforcement at all points of contacts.
Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Providing testing equipment & load and testing of 500mm dia under reamed pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 600mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 700mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed..
Providing testing equipment & load and testing of 900mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed..
Providing testing equipment & load and testing of 500mm dia under reamed pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 600mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 700mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 900mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Conducting standard penetration Test all as per IS-2131 at levels and locations as directed for 600mm, 700mm and 900mm dia cast in situ bored piles complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams,raft foundation etc all as specified and shown on drawings.
All as per Item No 36 herein before but depth exc 1.5m and not exc 3m all as specified and as directed by the Engineer-in-Charge.
Excavation over areas n exc 1.5m deep in soft / soil complete all as specified and directed.
Excavation over areas exc 1.5m n exc 3m deep in soft / soil complete all as specified and directed.
Returning filling in around pile cap, grade beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m deposited whereever dircted at a level not exc 1.5 m above starting point .
Formwork to sides of pile caps , grade beams rough finished surface of concrete flat all as specified .
Demolition of Existing Building No P-1 and P-2 including foundation complete all specified and as directed by the Engineer-in-Charge.
Demolition of Existing Building No P-34, P-34/1, P-34A and P-34B including foundation complete all specified and as directed by the Engineer-in-Charge.
Felling of trees exc 30cm and not exc 100cm girth including cutting of trunk and branches and stacking of serviceable material and disposal of unserviceable material to a distance not exc 50m and clearing site complete all as specified and sdirected by the Engineer-in-Charge.
All as per Item No 45 above but exc 100cm and not exc 150cm.
All as per Item No 45 above but exc 150cm and not exc 200cm.
All as per Item No 45 above but exc 250cm and not exc 300cm.
INTERNAL ELECTRIFICATION: Material and labour for Point wiring using approved colour coding as per IS with multi-stranded copper conductor 1.5 Sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete for One light/Ceiling Fan/exhaust fan controlled by one 5/6 amps one way switch .(NOTE: Switch and socket to be measured and paid for separately).
All as per Item No 49 herein before but One Socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 Amps one way switch or switch/socket combination 5 Amps, 5 pin.
All as per Item No 49 herein before but One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5Sqmm size
All as per Item No 49 herein before but One light point controlled by two switches 5/6 amps two way.
Material and labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) , including PVC insulated multi-stranded copper conductor 2.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed at site for one 3/5 pin 15/16Amps socket outlet independent .(NOTE: Switch and socket to be measured and paid for separately).
Supply and fix VTPN DB 8 way,suitable for 4 pole MCCB as incomer and TP/SP MCBs as out going,double door IP 43 protection, with 200A rated busbar, earth termination complete all as specified and directed by Engr-in-Charge (MDB for main supply)
Supply and fix VTPN DB 6 way,suitable for 4 pole MCCB as incomer and TP/SP MCBs as out going,double door IP 43 protection, with 200A rated busbar, earth termination complete all as specified and directed by Engr-in-Charge (MDB for AC)
Supply VTPN DB 4 way,suitable for 4 pole MCCB as incomer and TP/SP MCBs as out going,double door IP 43 protection, with 200A rated busbar, earth termination complete all as specified and directed by Engr-in-Charge (MBD for DG supply).
Supply and fix MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB TP 25 to 63 AMP 415V 10KA 'C' curve and current carrying capacity in the DB complete with connection testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB TPN 40 to 100 AMP 415V 10KA 'C' and current carrying capacity in the DB complete with connection testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP 5 to 32 AMP 240V 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP 40 AMP 240V 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN 32 AMP 240V 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN 40 to 63 AMP 240V 10KA 'C' curve and current carrying capacity in the DB complete with connection testing and commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix Ceiling fan 1200mm sweep copper wound having minimum service value 6.00 BEE five star rated with brushless direct current motor(BLDC) and min aie delivery 210CFM including fixing down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5Sqmm from ceiling rose to connector to fan all as specified and as directed by the Engineer-in-Charge.
Supply and fix Exhaust fan Steel body, 300 mm sweep 230 Volts AC 50 Hz, with blades, frame and louvers, including connecting up from ceiling rose with 3 core flexible copper cable, PVC sheathed of size 1.5 Sqmm, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix Round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Submain wiring in surface/recessed with 6 Sqmm two single core using multistranded copper conductor FRLS insulated unsheathed with and incl one run of 4Sqmm insulated unsheathed FRLS insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit medium grade ISI marked with accessories complete all as specified and as directed by the Engineer-in-Charge. (Note:2 runs of 6Sqmm , one run of 4Sqmm and one run of PVC conduit shall be measured as one run only
Material and labour for Submain wiring in surface/recessed with 10 Sqmm two single core using multistranded copper conductor FRLS insulated unsheathed with and incl one run of 6Sqmm insulated unsheathed FRLS insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit medium grade ISI marked with accessories complete all as specified and as directed by the Engineer-in-Charge. (Note:2 runs of 10Sqmm , one run of 6Sqmm and one run of PVC conduit shall be measured as one run only
Material and labour for Submain wiring in surface/recessed with 10 Sqmm four single core using multistranded copper conductor FRLS insulated unsheathed with and incl two runs of 6Sqmm insulated unsheathed FRLS insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit medium grade ISI marked with accessories complete all as specified and as directed by the Engineer-in-Charge. (Note:4 runs of 10Sqmm , 2 runs of 6Sqmm and one run of PVC conduit shall be measured as one run only
ROAD/PATH: Material and labour for 225mm thick WMM in three layers ( 75mm each layer ) using graded stone aggregate , spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and as directed by the Engineer-in-Charge.
SEWAGE DISPOSAL: Supply and laying DWCPE pipe 180mm dia laid in trenches including fittings complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M dia X 3 M effective depth. all as specified and as directed by the Engineer-in-Charge.
EXTERNAL WATER SUPPLY: Supply and lay Ductile Iron pipe, S/S including specials, Class “K-9” ,150 mm (6”) dia(Suction line) all as specified and as directed by the Engineer-in-Charge.
Supply and lay Ductile Iron pipe, S/S including specials, Class “K-9” ,100 mm (4”) dia all as specified and as directed by the Engineer-in-Charge.
Supply, installation, connecting and testing sluice valve cast iron body (Long Body) class –PN 1.0 with flanged ends drilled suitable for bore of pipe100 mm ISI marked (IS: 14846:2000) having brass spindle with iron wheel at top complete with nuts, bolts, washers, rubber gasket etc all as specified and as directed by the Engineer-in-Charge.
Material and labour for Masonary valve chamber, 100 mm thick foundation using PCC 1: 4: 8 , Type D-2, over 50mm thick hard core, 20 cm thick solid block masonry with blocks casting using PCC 1;3:6, type C-1, set in CM mortar 1:4, 15mm thick plaster to internal surfaces and external surfaces up to 15cm below ground level and to p of floor in in cement and sand mortor 1;4, finished even and smooth without using extra cement, 3mm thick MS sheet cover including 50mm x50mm x 6mm thick MS angle frame fixed in PCC 1;2;4, type B-1 copping with 25mm x 6mm flat angle hold fasts, handle, hinges with locking arrangements, applying two coats of synthetic enamel paint over a coat of red oxide paint and painting to cocrete surfaces and removal of surplus soil to a distance n exc 50m complete allas specified and directed of size 900x900x900 mm complete all as specified and directed
Supply and fix Pump set centrifugal electric driven 3Ph 415V, 50Hz mono block type including base plate having 7LPS at mtr head comprising CI impeller, SS shaft including wiring from starter to motor complete all as specified and as directed by the Engineer-in-Charge.
EXTERNAL ELECTRIFICATION: Supply, spreading and levelling riddled soil as earth cushioning to UG cable by using IS seive to seperate the composite/roots etc and refilling spreading in trenches as cushioning and rammed down to form a solid bed all as specified and directed at site. Note:- Punned thickness shall be measured and paid.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 185 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 400 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 150 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 95 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 50 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 35 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4core 25 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4core 10 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 2core 6 Sqmm all as specified and as directed by the Engineer-in-Charge.
Supply, install, testing and commissioning of factory made and CPRI tested out door type feeder pllar box suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 600 Amps for phases and 600 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories such as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties ( Location LTP No 1 of schematic plan)
INCOMINGS: (a)ACB 415 Volts,400 Amp rating, 3 Pole Microprocessor based (Service Breaking Capacity 50 kA 1 No.(b)Digital volt meter 0-500 Volts-01(c )Digital Ampere meter 0-1000 Amps with and including CTs OUTGOING: (a)MCB 415 Volts,250 Amp , rating 4 Pole , 25 kA 415 Volts 50 Hz- 02 Nos(AMF Panel and spare)(b)MCCB 100 A 18 kA 4 pole -03 Nos(Building load, cappacitor bank and spare)(c )Internal wiring of panel with stranded copper cable of suitable size(d)Neon phase indicating lamp(Set of three)-01 Set(e)Stenceling of pannel board including marking of distribuitions
Supply, install, testing and commissioning of factory made and CPRI tested outdoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 500 Amps for phases and 500 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.15 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties :-(Location: LTP No 2 of Schematic plan)
INCOMMING: (a)MCCB 415 Volts,320 Amp , rating 4 Pole, Thermal Magnetic release (Service Breaking Capacity 50 kA 1 Nos( Incomming).(b)Digital volt meter 0-500 Volts-01(c)Digital Ampere meter 0-500 Amps with and including CTs-01 No. OUTGOING: (a)MCCB 415 Volts,125 Amp , rating 4 Pole , 30 kA 415 Volts 50 Hz- 03 Nos (For for AC DB, Fire fighting, Building essentials and 01 No spare)(b)MCCB 415 Volts,40 Amp , rating 4 Pole, Thermal Magnetic release (Service Breaking Capacity 18 kA)- 05 No.(For water supply starter panel, Lift 1, Lift 2, Lift 3 and 01 No spare)(c )MCB 230 Volts,40 Amp , rating 2 Pole , 10 kA 230 Volts 50 Hz- 01 Nos (For pump house)(d)Internal wiring of panel with stranded copper cable of suitable size(e)Neon phase indicating lamp(Set of three)-01 Set(f)Stenceling of pannel board including marking of distribuitions
Supply and installation of HT 11 KV, 3 phase, 50 cycles, totally enclosed metal clad SF6 Switch gear Add ON type LBS to match with existing make & model of HT switch gear at site having Rupturing capacity upto 250 MVA, overload and earth fault protection, ammeter, voltmeter and of rating upto 400 Amp all as specified and as directed by the Engineer-in-Charge.
Supply and Installation of 11 KV Compact Sub Station with non extensible RMU consisting of 1 No manually operated 11 KV/630 Amps LBS in SF6 insulated stainless enclosure,HT Cable/Bus bar ,1 No transformer 250 KVA,11KV/433 CRT dry type & associated LT devices(ACB/MCCB/bus bar/Cable) all as specified and as directed by the Engineer-in-Charge.
Supply and fix LED Bolard light of IP 65/IK10 with base plate complete of Make Philips cat part No BCP151 LED 150/ NWPSU 220-240V7403HSN Code 9405 with and including PCC 1:2:4 type B1 using 20 mm graded agrigate of size 0.45 m x 0.45 m x 0.45m below normal ground level and foundation bolts as per manufacturers specification all as specified and as directed by the Engineer-in-Charge.
Supply and lay Rubber mat of 1 meter x 2 meter x 10 mm all as specified and as directed by the Engineer-in-Charge.
Supply and lay Rubber mat of 1 meter x 2 meter x 19 mm all as specified and as directed by the Engineer-in-Charge.
TELEPHONE AND TV POINT: Supply and fix Telephone Jack, modular, 1 Module, RJ 11, including GI flush box and white modular plate all as specified and as directed by the Engineer-in-Charge.
Supply and fix TV socket, modular, 1 Module, including GI flush box and white modular plate all as specified and as directed by the Engineer-in-Charge.
AVIATION OBSTRUCTION LIGHT: Supply and fix Aviation LED obstruction Lamp integral type with aluminium housing and polycarbonate diffuser, including one MCB SP 10A,Contactor,timer complete fixed in a sheet metal enclosure all as specified and as directed by the Engineer-in-Charge.
WATER COOLER: Supply, installation,commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 Ltrs all as specified and as directed by the Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 160 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA all as specified and as directed by the Engineer-in-Charge.
AIR CONDITIONING: Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity 2 TR all as specified and as directed by the Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 120 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA all as specified and as directed by the Engineer-in-Charge.
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20Amp single pole MCB all as specified and as directed by the Engineer-in-Charge.
Supply and fix APFC panel fabricated out of 2mm CRCA sheet duly compartmentalized suitable for 40 KVAR powder coated all as specified comprising of the following:- (i)Incomer- 63A MCCB, 415V, 3pole 25KA (ii)Capacitor bank 40KVAR(10x3+5x1+3x1+2x1)with capacitor duty contacts all as directed.(iii)APFC relay (iv)Digital multi-function meter to display current, voltage and power factor. (v)Copper bus bar, 3 phase 100A..
FIRE FIGHTING: Supply, installaion, testing and commissioning of slim seal type cast iron butterfly valves , bronze/ Gun metal seat of size 40 mm dia, PN 1.6, lever operated type with necessary flanges, nuts, rubber insertion gaskets, nuts and bolts complete all as specified and as directed by the Engineer-in-Charge.
Supply, installaion, testing and commissioning of slim seal type cast iron butterfly valves , bronze/ Gun metal seat of size 25 mm dia, PN 1.6, lever operated type with necessary flanges, nuts, rubber insertion gaskets, nuts and bolts complete all as specified and as directed by the Engineer-in-Charge.
Supply and Install Diesel Engine driven fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % suitable rating and capacity diesel engine to drive the pump 70 m Head. 2280 LPM discharge complete all as specified and as directed by the Engineer-in-Charge.
Supply, installaion, testing and commissioning of non return valve 200 horizontal type cast iron double flanged conforming to IS 5312 with bolts, nuts, washers, 3 mm thick insertion rubber gaskets complete all as specified and as directed by the Engineer-in-Charge.
Supply, installaion, testing and commissioning of non return valve 150 horizontal type cast iron double flanged conforming to IS 5312 with bolts, nuts, washers, 3 mm thick insertion rubber gaskets complete as reqd. all as specified and as directed by the Engineer-in-Charge.
Supply, installaion, testing and commissioning of non return valve 100 horizontal type cast iron double flanged conforming to IS 5312 with bolts, nuts, washers, 3 mm thick insertion rubber gaskets complete as reqd all as specified and as directed by the Engineer-in-Charge.
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia all as specified and as directed by the Engineer-in-Charge.
Supplyand laying UG cable 2Core 1.5 Sqmm copper cable ISI marked with proper clamping, supports and terminations all as specified and as directed by the Engineer-in-Charge.
Supply, installation, testing and commissioning of Addressable type Active Loop Repeater Panel (Loop power/external power) Fire terminal, Backlit LCD Display 6x40 characters display, having Controls for Reset, Mute, Accept, Silence alarms and Self Test with programmable free Keys and Duly approved by UL/FM (repeater panel should be placed in Guruda Fire Station). all as specified and as directed by the Engineer-in-Charge.
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 160 KW (200 KVA), Water cooled, 415 Volts(AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Kochi.(Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,4/6 cylinders ,four stroke, confirming to ISO3046/BS 5514, Water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 160 KW (200 KVA) at outdoor atmospheric conditions at Kochi. ,(Taking all derating factor into consideration), , 12/24 Volt(as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with techometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system(Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc.
Note:- The emissiom limits of DG sets shall not exceed the limit specified by CPCB document, 'System and Procedure for Compliance to Emission Limits for Diesel Engines' and in consonance with the Environment(protection)Thied Amendment Rules 2013 and its subject amendment vide GSB 232(E) dt 31 Mar 2014 GSR 789(E) dt 11 Nov 2014 and GSR 105(E) dt 17 Feb 2015 at Sl No 95 issued by Ministry of Environment and Forests, Government of India. The valves as per current amendment is appended below and the latest valve at the times of procurement shall be adopted". Emission Limits Oxides of Nitrogen + Hydro Carbon(NOx+HC) < 4(g/k W-hr) Carbon Monoxide < 4(g/k W-hr) Particulate Matter < 4(g/k W-hr) Smoke limit(Light Absorption Coefficient , m -1 < 7
SOLAR POWER PLANT : ROOF TOP SPV PLANT:Designing, supply, erection, installation,commissioning and testing of Roof top solar photovoltaic power plant (ON-GRID) on roof top of proposed Building of total capacity 40 KWp (AC) fixed tilt type, and power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Meteorological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal Irradiance etc complete comprising with the following:-
SOLAR PHOTO VOLTAIC PLANT: Supply, erection, installation, commissioning and testing Solar PV Modules capable for generating 40 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules shall be as per approved design parameters, with Mono Crystalline Silicon Solar cells of minimum wattage of 330/325 Wp with minimum 72 cells & efficiency not less than 18 %, conforming to IEC 61215, IEC 61730, IEC 61701, IEC-61646, IEC-62108 and must be tested and approved by one of the IEC authorised test centre. Solar PV Module and cells should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules will be warranted for a minimum period of 25 years. Solar PV modules used in System must be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module: -
(a)Name of manufacture of PV module (b) Name of manufacturer of Solar cell(c ) Month & year of manufacturer (for solar cell and module) (d)Country of origine (It is mandatory to use cells and modules manufactured in India)(e)I-V curve of the module, Wattage(f) L-M, V-M & FF for the module(g) Unique Serial No & Model No of the module(h) Date & year of IEC PV qualification certificate(j) Name of the test lab issued IEC certificate(k)The PV modules used in the solar power projects must qualify to the latest edition of the following International Electrotechnical Commission (IEC) PV module qualification test or equivalent BIS Standards(l) The PV module must be tested and approved by one of the IEC authorized test centres(m) In addition, a PV module qualification test certificate as per IEC standard, issued by EDTC(n)Bangalore or solar energy entre will also be valid(o) BIS Standards
(p)Crystalline Silicon Solar Cell Mopdules: IEC 61215/BIS 14286(q) Thin Film Modules: IEC 61646 / Equivalent BIS(r)Concentrator PV Modules : IEC 62108 / Equivalent BIS(s) PV modules sandy environment: IEC 600068-2-68(t)PV modules corrosive atmosphere: IEC 61701 / BIS 61701(u) PV module (For construction & safety): IEC 61730 (part I & II ) / Equivalent BIS(v)Material and labour for Module Mounting structure (MMS) fabricted from hot dipped GI section of suitable size with specified tilt angle according to site requirement & Optimum angle to achieve Max benefit of solar energy and suitable to withstand 150 Kmph wind speed all as approved design parameters complete. Module mounting structure on GI roof sheets are to be fixed to the roof sheets by using specially designed clips to mount the PV Panel on roofing system as per approved pattern of roof sheets.(w)Supply , laying & Testing required qty of DC cable 1x 4 sq mm multi strand tinned copper, conforming to relavant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules including suitable type of cable lugs, male & female MC4 connectors & joints etc. (x)Supplying, erection, installation, commissioning and testing required qty of junction boxes / SMBs for 40 KWp AC output all as per approved design & layout plan for combining output of Solar PV modules DC rating of breaker of designed rating with string fuses on both positive and negative side of each string complete with SMB Voltage rating 1000 V, Copper bus bar, weather proof enclosure with NEMA rating complete.
(y)Supply , laying & Testing required qty of DC cable 2 runs 1x 6 sq mm multi strand tinned copper conductor through PVC conduit 20 mm dia ISI marked, weather proof UV resistant with operating temperature up to 120 degrees for connection from String junction box to Inverter / PCUs including suitable type of cable lugs, male & female MC4 connectors & joints etc. (z)Supply, erection, installation, commissioning and testing of Grid tie Solar Power conditioning unit / inverter of total capacity 40 KWp (DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 /VDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short/over current protection, and DC reverse polarity protection, graphic display etc. all as specified and as directed.(aa)Nominal Voltage: 415V ± 10%, 3 Phase, 50 Hz.(bb)Control: Microprocessor / DSP(cc)Switching device: IGBT / MOSFET(dd)Grid Freq Synchronization: ± 3 Hz or more(ee)Ambient Temperature: -20˚C to 50˚C(ff)Humidity: 95 % non-condensing Protection of enclosure: IP 20 ( Indoor) / IP 65 ( outdoor)
(gg)No Load Losses: < 1% of rated power(hh)Inverter Efficiency: >97% ( without inbuilt galvanic isolation)(jj)>93% ( with inbuilt galvanic isolation)(kk)PF: >0.>0.9(ll)THD: <3%(mm)The Inverter should have internal protection arrangement against any sustainable fault in feeder line and against the lighting on feeder(nn)Should have isolation transformer.(oo)The inverter generated harmonics, flicker, DC injection limits, Volt range, frequency range and anti-islanding measures should follow the latest guidelines / IEC 62116/ BIS Code.(pp)AC, 415V copper cables or required size from individual inverter to invertor panels and invertor panel for evacuating 200 KW AC supply are deemed to be included in the rate againt SPV Plant and nothing extra shall be payable on this acount Copper cables (qq)Technical requirement of BoS items of SPV plants: Technical specifications of power conditioners including MMPT & Protection for use in grid solar power plants are as under: -
Environmental Testing:IEC 60068-2/ Eq IS. Efficiency Measurement:IEC 616833 / IS 61683. Product safety: IEC 62109- 1 & 2. Grid connectivity Interface: IEC 61727:2004.Interconnection PV invertors: IEC 62116. Electromagnetic interface: IEC610002,3,6. Ingress protection: IP 54 & IP 21.Batteries: AS PER relevant BIS Std. Cables: IEC 60227/IS 3043:1986. Earthing / Lightening: IEC 62561/IS 3043 :1986Surge arrestors: IEC 60634-5-53/Relevant IS Code. Circuit Breakers: IEC 60947 1, 11,III 60947 EN 50521. Junction Boxes & Enclosures: IP 65 / IP 21. Meters: AS Per DISCOM Guidelines / IS 16444. Grid connectivity: As prevalent in the state/as per CEA. Warranty : The mechanical structures, electrical works, and SPV power system must be warranted for a minimum of 5 Years. Supply,installation,commissioning and testing of LT 415 Volt GRID panels outdoor type for Power evacuation and Grid interconnection systems with the existing LT Panel at loaction marked in the Drg / directed by Engr-in-charge at site with rated capacity of Circuit Breakers at both side, bus bar, CTs, digital Metering , relays,Gross-metering, etc all as per approved design parameters with totally enclosed, fully interlocked, metal clad power coated enclosure including PCC foundation complete. Note: Earth work & LT cable of sizes required for connection from Inverter panel to Grid panel shall be measured and paid separately. Modification of existing LT panel / Feeder pillar box by exentesion of busbar for inter connection with and including MCCBs of rated capacity, sheet metal enclosure complete & connecting.
Material and labour for required qty of Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including GI strip 32x6mm size protected with G I medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work, excavation, PCC pit and RCC cover ( 1:2:4 type B1) and funnel, with necessary charcoal, salt etc;complete all as per electrical plate No.3 of SSR Part - I.Material and labour for aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection.Material and labour for artistic painting in black letters with yellow background for Solar array structures, junction box , Earth chambers, PCU's, DB's etc.. all as specified and as directed.Material and labour for earthing for Lightning protection of Panels, Inverter etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including GI strip 32x6mm size protected with G I medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work, excavation, PCC pit and RCC cover ( 1:2:4 type B1) and funnel, with necessary charcoal, salt etc;complete all as per electrical plate No.3 of SSR Part - I.Supply & lay synthetic rubber mat of size 2m x 1m x 10mm - 01 No each per panel. Note I:Before commencement of work, contractor shall submit working drawings & lay out plan with scale including qty required duly vetted by IIT/NIT to Accepting Officer for approval. The working drawing must includes the following.(a)Single line/Schematic diagram of Solar PV power plant
(b) Designing of Solar PV strings layout, SMBs / junction boxes , Cable route etc(c) Details of Mounting Structure,roof clips, tilting angle, size of sections, junction box,position, LT Cable Network (DC & AC) layout, Lightening Protection System, Earthing System Invertor type & make etc.(d) Any other details required for successful installation commissioning, testing and smooth and stable operation of Solar PV plant. Note II: (a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/IS/equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical & electrical) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 200 KW (AC) all as mentioned above and which is not mentioned or included in this Schedule A , but necessary shall be carried out by the contractor.(d) Contractor shall provide adequate Spares required minimum for 1 year maintenace including DC & AC items under scope of work Note III:(a) Entire plant shall be tested after successful commissioning by Senior Electrical Inspector.(b) Contractor shall organize presence of an electrical consultant at site at the time of commissioning with no additional charges to MES. The consultant / site engineer shall have adequate expertise in the form of knowledge/ experience in this field. He shall be able to guide the site team on the steps/ procedure/ precautions to be adopted during commissioning. Also, he shall be cable of extempore trouble-shooting in case of any technical problems encountered on SPV portions up to connection to existing LT distribution system. Contractor will submit credentials of the proposed consultant for MES approval prior to awarding of work/ availing their service.
(a)LED lighting connected to inverter supply and one cabin fan 300mm sweep in lift car and counter weight.(b) Electric motor AC, 3 phase 415Volts, 50Hz of suitable capacity including cabling necessary conduits as required.(c) Type of operation shall be single automatic pushbutton type.(d) Type of control-16 bit microprocessor variable voltage and variable frequency(V3F). (e) Type of signal system- Hall button with digital car position indicator in stainless steel face plates.(f) Minimum size of clear entrance opening of car for passenger lift shall be 900mm(W) x 2000mm(H) with automatic center opening. (g)Automatic rescue device battery operated to bring the car cage to the nearest floor level and auto opening for evacuation of passengers in the event of power failure. Capacity of ARD battery should be suitable to perform minimum three rescue operation.( h)Earthing shall be connected with suitable size copper earth wire from earth plate to control panel in machine room.(j) Pit Ladder (k)Hand rail 50mm dia SS.
Supply and fix MCCB with thermal /magnetic release of 4 pole 40 Amps, 16 kA with and in including sheet steel enclosure with one set of phase indicating lamp, volt meter0-500V-01 No, amphere meter with CTs(set of 3)Range 0-100 Amps-01 set. The enclosure shall be wall mounted with and including all fixing accessories all as specified and as directed by the Engineer-in-Charge.
Design, Supply, Installation, testing and commossioning of electrically operated 13 passenger capsule/panorama type lift for 13 persons (884Kg) capacity, with following features:(a)MACHINE TYPE: PM Gearless Motor(b)CONTORLLER TYPE:AC – VVVF(c)CAPACITY IN KGS/PERSONS: 884Kg / 13P(d)SPEED MPM : 1.50MPS / 90mpm(e)MACHINE ROOM LOCATION: Above the Hoistway(f)DOOR OPENING TYPE: 2CO (Centre Opening)(g)OPERATION: Simplex(h)NO.OF STOPS: 7 Stops(j)NO.OF OPENINGS: 7 Openings(k)CABIN DIMENSIONS (W)X(D)X(H) (MM): 1600 X 1350 X 2200(l)PIT DEPTH (MM): 1600(m)OVERHEAD (MM): 4200(n)ENTRANCE DIMENSIONS (MM): 900 X 2000 (o)CEILING:SS Brushed Ceiling with lighting energy saving LED downlight.(p)CAR OPERATING PANEL:1 no. COB- IN-INM01 Combined unit with LED display in orange indicating the position of the car & direction indicator with Flat button with orange illumination when call is registered, faceplate in Brushed finished stainless steel.(q)CAR FRONT PANEL:Stainless Steel Honeycomb finish 304 Grade(r)CAR REAR PANEL :Transparent Glass with SS304 Frame (s)CAR SIDE PANEL: Stainless Steel Honeycomb finish 304 Grade (t)HANDRAIL - Pipe type Provided - 38mm dia.on rear Wall(u)CAR DOORS: Stainless Steel Honeycomb finish 304 Grade(v)CAR FLOORING: 25mm recess (flooring by customer)(w)FLOOR THICKNESS:NA(x)CAR SILL:Extruded Hard Aluminium LANDING FIXTURES/FINISHES ALL FLOORS(y)ENTRANCE FRAMES:Stainless Steel Brushed finish 304 Grade (z)LANDING DOORS:Stainless Steel Honeycomb finish 304 Grade
(aa)HALL CALL BOX:HB-IN-INM01 Combined unit with LED display in orange on the top indicating the direction of travel and floor number, Flat acrylic button with illumination in orange when call is registered.(ab)HALL CALL BOX FACE PLATE: Stainless Steel Brushed Finish(ac)LANDING SILL:Extruded Hard Aluminium(ad)Full collective operation:A number of “Up & Down” hall calls and car calls can be uniformly registered. The elevator runs its travel responding to calls registered in a single travel direction.(ae)LANDIC (Automatic Rescue Device):Battery operated Automatic Landing Operation during power failure(af)Interphone:Intercom is provided in car, G floor lobby and last landing floor and is used for communication with the passengers inside the cabin and during maintenance of elevator.(ag)Emergency alarm device:When the emergency car buttons in the cabin operating board is pressed, the alarm fixed at the top of the car will ring. The pressing of the alarm bell will also simultaneously ring the intercom installed outside the car.(al)Emergency Light:(with self charging and discharging)When the power for car lights is cut off due to the power failure , etc., emergency light in the car is lit immediately for the passenger’s safety(am)Over-load protection:The ventilation and light Will automatically cut off when the elevator is not in use.(an)Self Check Operation:Elevator self-diagnostic operation system, Automatically checks critical operation parameters and braking systems to ensure user safety(ao)VONIC (Voice announciator):Floor announcement
(ap)Light and ventilation in car(Automatic Fan and Light Control):Automatically switch off during ideal position(aq)Calls in opposite direction auto-clear:Car Calls for floors in the opposite direction of moving car will not be registered to prevent nuisance calls.(ar)Cancel error calls:When a floor button is pressed erroneously, a passenger may press the incorrect destination button twice to cancel the call.(as)Attendant Operation:Switches for Attendant Operation(at)Rescue operation to the nearest landing (in case of door failure): When the elevator arrives at a landing and is unable to open the doors, the elevator will automatically processed to the next landing and open the door
Supply and fix LT panel fabricated out of 2mm CRCA sheet wall mounting or stand alone type compartmentalized for the following items duly powder coat painting of approved colour:- (i) Bus bar- 100A(1 set)RYBN (ii) MCCB 63Amps, 4P, 16KA-1No(I/C) (iii) MCB 40A, 4P 10KA-2Nos(iv)MCB SPN 32Amps, 10KA - 1No (v) FASD starter for 7.5/10HP motor (vi) LED indicator- 1 set(RYB) (vii) Digital volt meter- 1No (viii) Digital Ammeter-1No
Supply and planting Bermuda grass(by bibbling method @7.5cm apart) over prepared surface with adequately developed root after providing antitermite treatment including preparation of surfaces, earth work excavation, removing surplus soil, filling of approved earth suitable for grassing 20cm thick after mixing of fertilizer/organic manure and regular maintenance of developed grass for one year all as specified and as directed by the Engineer-in-Charge.
Material and labour for Comprehensive maintenance of electrically operated 13 passenger lift of capacity 884Kg to derve (G+6) and panorama type lift(G+6) installed at Naval Base Kochi for First Year after expiry of Defects liability period all as specified and as directed by OEM
All as per Item No 142 here in before but for Second Year after defect liability period
All as per item No 142 here-in-above, but for third year after defect liability period . Note for Item No.142 to 144:- (a)No spare parts shall be supplied by the department. (b)The rate for maintenance, service and repair include all the materials and labour required for the satisfactory functioning of the lifts as stipulated on particular specifications.
JAIN BUILDER
PPJOHN
Crescent Construction Company
Kurian And Varghese
Mecone Construction Contractors
Agarwal Jagdish Construction Company Pvt. Ltd.
S.S.NATARAJAN AND CO
KCP INFRA LIMITED
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid