Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹1.3 Cr+₹20.2 L (18.1%)Rejected-Finance OPPOSITE SWAHID BHAWAN VILL MIRZA P O MIRZA DIST KAMRUP 781125 | MIRZA | KAMRUP | ASSAM | 781125 | ₹1.3 Cr+₹20.2 L (18.1%) | L2 | Rejected-Finance L2 bidder |
| 3 | L3₹1.4 Cr+₹29.0 L (26.0%)Rejected-Finance JATIA GUWAHATI | GUWAHATI | ₹1.4 Cr+₹29.0 L (26.0%) | L3 | Rejected-Finance L3 bidder |
| 4 | L4₹1.4 Cr+₹29.5 L (26.4%)Rejected-Finance GROUND FLOOR PURVI COMPLEX A T ROAD NEAR PANBAZAAR OVERBRIDGE KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹1.4 Cr+₹29.5 L (26.4%) | L4 | Rejected-Finance L4 bidder |
Tender Value
₹1.2 Cr
EMD Value
₹2.5 L
Closing Date
13 Aug 2024, 12:00 pmClosed
CGM (OnM), CAR
Bijulee Bhawan, Paltan Bazar, Guwahati-01
Turnkey construction of 33kV Meherpur Feeder Bay along with necessary 33kV Bus Extension works at 132kV Srikona GSS
2024_AEGCL_37718_1
OnM/CAR/Meherpur/2023/BID
Open Tender
Electrical Works
Works
240 days
132kV Srikona GSS
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹2.5 L
5 Dec 2024
24 Jun 2024
14 Aug 2024
24 Jun 2024
13 Aug 2024
25 Jun 2024
24 Jun 2024 - 1 Jul 2024
Amount
Supply of Circuit Breaker with mounting structure and terminal connectors as required . 33kV, 25 KA, 800A Gang operated Vacuum Circuit Breaker
Supply of feeder Current transformers (1-Phase, 0.2 class live tank type) including all accessories and terminal connectors as required. 33 kV, 400/1-1 A, 2 Core Single Phase CT
Supply of 33 kV, 25 KA, 1250A motor operated Isolators with terminal connectors and complete with all fittings and fixtures. With Earth Switch
Supply of 33 kV, 25 KA, 1250A motor operated Isolators with terminal connectors and complete with all fittings and fixtures. Without Earth Switch (for Bus Isolators & Bus Couplar)
Supply of 33kV Lightning Arrester with surge monitor & terminal connectors complete.
Supply of 33kV Post Insulator with terminal connectors.
Supply of Equipment mounting structure with all nuts and bolts complete for 33 KV CT
Supply of Equipment mounting structure with all nuts and bolts complete for 33 KV motor operated Isolators with earth switch
Supply of Equipment mounting structure with all nuts and bolts complete for 33 KV motor operated Isolators without earth switch
Supply of Equipment mounting structure with all nuts and bolts complete for 33 KV LA
Supply of Equipment mounting structure with all nuts and bolts complete for 33 KV PI
Supply of 33kV Feeder Control & Relay panel (With BCU) Simplex type, capable of integration into the SIEMENS SAS.
Managed Ethernet switch with OF PATCH
SAMAST complaint ABT energy meter including installation
T clamps for connection to Bus (Zebra to Zebra)
ACSR Zebra conductor
Double tension clamps with hardware fittings along with D-cycle and arching horn for ACSR zebra conductor, EYE & Cleaves Dia 16 mm
Double suspension clamps with all hardware fitting along with D-cycle and arching horn for ACSR zebra conductor
90 KN Porcelain insulator, 11kV B & S type
Supply of armoured Power Cables 2C, 6 sqmm
Supply of armoured Power Cables 4C, 16 sqmm
Supply of armoured Power Cables 3 ⅟₂ C, 35 sqmm
Supply of armoured Control Cables (Cu) 4C, 2.5 sqmm
Supply of armoured Control Cables (Cu) 7C, 1.5 sqmm
Supply of armoured Control Cables (Cu) 12C, 1.5 sqmm
Supply and Installation of AC marshalling kiosk including construction of foundation, installation and cable foundation
Supply of 33kV Switchyard Structures Column : 8 nos (1MT approx each)
Supply of 33kV Switchyard Structures Beam Type: 5 nos (0.5 MT aprox each)
Supply of LED Lighting set with all fitings for substaion illumination.
Earth mat extension and equipment earthing. Main Earth mat (65x12 mm GI Flat)
Earth mat extension and equipment earthing. 50x6 GI flat Earthing conductor for earthing of indoor L.T & control panels, Junction box, Marshalling boxes, cable trenches etc.
Earth mat extension and equipment earthing. 100 mm Dia. 3mtr long M.S. rod earth electrode
Mandatory Spares 33kV, 25 kA, 1250A Isolators Female contact (Entire Assembly)
Mandatory Spares 33kV, 25 kA, 1250A Isolators Moving contact (Entire Blade Assembly)
Mandatory Spares 33 kV, 400/1-1 A, 2 Core Single Phase CT
Mandatory Spares Lightning Arrestor
Mandatory Spares Numeric Back up Relay
Mandatory Spares Master Trip Relay
Mandatory Spares Bay Control Unit
Mandatory Spares Clamps and terminal connectors (T clamps) Zebra-Zebra
Mandatory Spares OFC Patch Card (a) ST-LC
Mandatory Spares OFC Patch Card (a) ST-ST
Mandatory Spares for 33kV CB Closing Coil
Mandatory Spares for 33kV CB Tripping Coil
Mandatory Spares for 33kV CB Spring charging motor
Mandatory Spares for 33kV CB Operating mechanism
Mandatory Spares for 33kV CB SF6 Gas Density Monitor
Description of Work / Item(s)
Amount
Erection, testing & commissioning of Equipment including laying & terminating of LT power and control cables, connection of terminal clamp connectors as required and equipment earthing of: 36 kV Gang operated Vacuum Circuit Breaker.
Erection, testing & commissioning of Equipment including laying & terminating of LT power and control cables, connection of terminal clamp connectors as required and equipment earthing of: 33 kV, 400/1-1 A, 2 Core Single Phase CT including marshalling box.
Erection, testing & commissioning of Equipment including laying & terminating of LT power and control cables, connection of terminal clamp connectors as required and equipment earthing of: 33kV Isolator with Earth Switch
Erection, testing & commissioning of Equipment including laying & terminating of LT power and control cables, connection of terminal clamp connectors as required and equipment earthing of: 33kV isolator without Earth Switch. ( For bus isolator & Bus Coupler)
Erection, testing & commissioning of Equipment including laying & terminating of LT power and control cables, connection of terminal clamp connectors as required and equipment earthing of: 33 kV Lightning Arrestor
Erection, testing & commissioning of Equipment including laying & terminating of LT power and control cables, connection of terminal clamp connectors as required and equipment earthing of: 33 kV Post Insulator
Erection of equipment mounting structure including excavation, construction of foundation, backfilling, compacting and supply of all foundation materials and labour as per supervision of site engineer 33 kV Gang operated Vacuum Circuit Breaker.
Erection of equipment mounting structure including excavation, construction of foundation, backfilling, compacting and supply of all foundation materials and labour as per supervision of site engineer 33 kV, 400/1-1 A, 2 Core Single Phase CT including marshalling box.
Erection of equipment mounting structure including excavation, construction of foundation, backfilling, compacting and supply of all foundation materials and labour as per supervision of site engineer 33kV Isolator with Earth Switch
Erection of equipment mounting structure including excavation, construction of foundation, backfilling, compacting and supply of all foundation materials and labour as per supervision of site engineer 33kV isolator without Earth Switch. ( For bus isolator & Bus Coupler)
Erection of equipment mounting structure including excavation, construction of foundation, backfilling, compacting and supply of all foundation materials and labour as per supervision of site engineer 33 kV Lightning Arrestor
Erection of equipment mounting structure including excavation, construction of foundation, backfilling, compacting and supply of all foundation materials and labour as per supervision of site engineer 33 kV Post Insulator
Construction of Foundation for lattice steel columns including supply of all foundation materials and labour Column: 8 Nos
Erection of lattice Steel tructures along with structure earthing. Column : 8 nos (1MT approx each)
Erection of lattice Steel tructures along with structure earthing. Beam Type : 5 nos (0.5MT approx each)
Installation, testing and commissioning of 33kV Feeder Control & Relay panel: Installation in KIOSK, including testing, commissioning of C&R panel
Installation, testing and commissioning of 33kV Feeder Control & Relay panel: Installation of C&R panel into existing SAS including testing and commissioning
Construction of Covered Cable Trenches including supply of all foundation materials and labour as per specification and drawing: Type - C
Construction of Covered Cable Trenches including supply of all foundation materials and labour as per specification and drawing: Type - D
Providing 80mm thick 1:4:8 PCC base of switchyard as per specification & Drawing including supply of all materials and labour.
Providing 100mm thick gravelling on the switchyard including levelling etc as per directive of site engineer.
Installation of earthing system : Installation of Main Earth mat (65x12 mm GI Flat) and connection to riser including painting of welding joints with bitumen paint and connecting to main earth mat.
Installation of earthing system : Installation M.S. rod earth electrode (driven) with test link including making necessary connections and construction of covered earth pits
Hanging of twin disc insulator string for both tension and suspension insulator along with twin jumpering with clamps and conductors for the extended 33kV bus
P & S CONSTRUCTION (BID ID -234766)
ARADHANA AGENCY (BID ID -236191)
OK Enterprise (BID ID -236720)
P & S CONSTRUCTION (BID ID -234766)
ARADHANA AGENCY (BID ID -236191)
OK Enterprise (BID ID -236720)
Bidder Name
OK Enterprise
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .