Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-Finance | ₹33.2 L | L1 | Accepted-Finance L1 |
| 2 | L2₹34.0 L+₹75,000 (2.26%)Rejected-Finance | ₹34.0 L+₹75,000 (2.26%) | L2 | Rejected-Finance L2 |
| 3 | L3₹42.7 L+₹9.5 L (28.5%)Rejected-Finance VILL SAKRAH PO CHAMBI TEHSIL SUNDERNAGAR DISTT MANDI HP | SUNDERNAGAR | MANDI | HIMACHAL PRADESH | ₹42.7 L+₹9.5 L (28.5%) | L3 | Rejected-Finance L3 |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-The contractor/firm has uploaded all the documents as per NIT requirement. But the uploaded document of enlistment is tempered and not visible and the GST registration is not on the required form. on the basis of these documents the contractor has be |
| Sl No | Description | Qty | Unit | DHANANJAY SINGH SLATHIA L2 | KUSHAL SINGH RAGHAV L3 | General Machinery Corporation L1 |
|---|---|---|---|---|---|---|
| 1.00 | Providing horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/Kirlosker or any other approved by HPJSV as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS Base plate induction motor type TEFC IE 2 or above of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:12615/2018 with upto date ammendments read with IS 900:1972 or other relevant IS code. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:
Discharge (Q) 17.13 LPS for each pump, Total Dynamic head 354.98 meter, LWL in sump well (h) 798.50 meter Shaft level 800.00 meter level at discharge point 1136.00 meter Suction lift -ve Discharge Head 354.98 meter Static Head 336.00 meter Rising main Length 1250 meter dia 200mm Pumping hours 16 hours Altitude of installation above MSL 800 meter Characterstics of water Clear water with turbidity upto 50 PPM Temperature 25 degree cent. | 2 | Set of 150 HP | 11,90,000 ₹23,80,000 | 14,75,000 ₹29,50,000 | 11,53,000 ₹23,06,000 Lowest |
| 2.00 | Providing Change over switch fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. | 1 | set | 22,000 ₹22,000 Lowest | 37,500 ₹37,500 | 22,000 ₹22,000 Lowest |
| 3.00 | Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities | 1 | No. | 12,000 ₹12,000 Lowest | 35,000 ₹35,000 | 12,000 ₹12,000 Lowest |
| 3.01 | a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments | 1 | No. | 25,000 ₹25,000 Lowest | 52,500 ₹52,500 | 25,000 ₹25,000 Lowest |
| 3.02 | b) Earth leakage circuit breaker of recommended make Chief Electrical Inspector approved with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end. | 1 | No. | 4,000 ₹4,000 Lowest | 7,500 ₹7,500 | 4,000 ₹4,000 Lowest |
| 3.03 | c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition) | 1 | No. | 1,000 ₹1,000 Lowest | 1,500 ₹1,500 | 1,000 ₹1,000 Lowest |
| 3.04 | d) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments | 1 | set | 25,000 ₹25,000 | 11,000 ₹11,000 Lowest | 25,000 ₹25,000 |
| 3.05 | e) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments | 2 | set | 20,000 ₹40,000 Lowest | 32,500 ₹65,000 | 20,000 ₹40,000 Lowest |
| 3.06 | f) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments | 2 | set | 500 ₹1,000 Lowest | 750 ₹1,500 | 500 ₹1,000 Lowest |
| 3.07 | g) Digital 100mm dia Square dial A.C.supply VAF meter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments | 2 | set | 5,500 ₹11,000 | 5,250 ₹10,500 Lowest | 5,500 ₹11,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Mar 2026, 5:00 pmClosed
EXECUTIVE ENGINEER
JAL SHAKTI DIVISION KARSOG
RR Damages of LIS Chakhana Tuman in Tehsil Karsog Distt Mandi HP
2026_HPIPH_130645_1
2026_HPIPH_MARCH_CHAKHANATUMAN
Open Tender
Civil Works - Others
Item Wise
90 days
Karsog
RR Damages of LIS Chakhana Tuman in Tehsil Karsog Distt Mandi HP
8 documents required · 8 mandatory
₹1,500
₹60,000
16 Jul 2026
9 Mar 2026
17 Mar 2026
9 Mar 2026
16 Mar 2026
9 Mar 2026
9 Mar 2026 - 9 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage centrifugal pump or combination of pumps, In series/parallel of recommended make such as Mather and Platt/KSB/Kirlosker or any other approved by HPJSV as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 4508 FN8 with cast iron casing coupled directly through a flexible coupling on a common MS Base plate induction motor type TEFC IE 2 or above of standard make such as Kirlosker/BHEL /Crompton /NGEF /GEC/Siemens/Jyoti /ABB and suitable for operation on 400(+/-)10% volts,50 cycles /second.3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:12615/2018 with upto date ammendments read with IS 900:1972 or other relevant IS code. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements:
Discharge (Q) 17.13 LPS for each pump, Total Dynamic head 354.98 meter, LWL in sump well (h) 798.50 meter Shaft level 800.00 meter level at discharge point 1136.00 meter Suction lift -ve Discharge Head 354.98 meter Static Head 336.00 meter Rising main Length 1250 meter dia 200mm Pumping hours 16 hours Altitude of installation above MSL 800 meter Characterstics of water Clear water with turbidity upto 50 PPM Temperature 25 degree cent. | 2 | Set of 150 HP | - | - |
| 2 | Providing Change over switch fuses of Kilburn/ L&T/Siemens/Standard/ Havells make and having capacity 30% extra of the operational rating as per IS: 4064-1978 with up to date amendments , immediately after the power meter of the HPSEBL. | 1 | set | - | - |
| 3 | Providing MS sheet steel fabricated floor mounted closed(almirah type) switch board including angle iron post of suitable height and size ISA 40x4r0x6 duly painted with steel sheet of 16 gauge comprising and capable of mounting the following accessories within all internal connections. All the accessories should be suitable for the proposed pumping machinery at item No.1 above and to the entire satisfaction of HPSEB authorities. The same shall have to be replaced with out extra cost if recommended by HPSEB authorities | 1 | No. | - | - |
| 3.01 | a) OCB/MCCB of MEI/Havels/ standard make and of suitable capacity for offered motor on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage released as per relevent IS code with upto date ammendments | 1 | No. | - | - |
| 3.02 | b) Earth leakage circuit breaker of recommended make Chief Electrical Inspector approved with upto date ammendments of suitable range which should have control box, operation, handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the ciruit breaking for cover current protection. The circuit should be equipped with magnet thermal release with metallic tap etc, it should also be fitted with earth fault for tripping of breaker on occurnce of earth fault on off breaker load side end. | 1 | No. | - | - |
| 3.03 | c) The voltage monitor relay of AE/MEI/L&T / Havells make three phase with all protection and usual indicator and electric siren against single phasing,low voltage,high voltage, reverse phasing, over loading and phase voltage difference as per IS:3482(latest edition) | 1 | No. | - | - |
| 3.04 | d) Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and suitable for inducted current, one copper bar of half the rating of full length for neutral phase as per IS 8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments | 1 | set | - | - |
| 3.05 | e) ICTP switches with HRC fuses unit of Kilbur/L&T/siemens/stands/Havells make and of suitable capacity as per IS:4064:1978 with upto date ammendments | 2 | set | - | - |
| 3.06 | f) Three phase indicator lamps complete with toggle switches for individual motors as per IS:3452:(P-I & II) with upto date ammendments | 2 | set | - | - |
| 3.07 | g) Digital 100mm dia Square dial A.C.supply VAF meter of AE/IMP/Havells make of suitable range with selector switches and CTS operated as per IS:L1248(P-II) .183 with upto date ammendments | 2 | set | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.33 MB
TCTWO.pdf
Additional Documents • 1.55 MB
BOQ_193463.xls
BOQ • 0.25 MB
TC.pdf
Tender Documents • 1.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .