| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹31.5 L+₹1.4 L (4.66%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹38.2 L+₹8.1 L (27.0%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VIJAYVARGIA ELECTRICALS L3 | NEW INDIA ELECTRIC WORKS L2 | SUNRISE ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.00Testing of motors and recording of IR values and other electrical parameters, Disconnection of power cables & space heater cables and earthing connections ; Rigging is under scope of contractor; Transportation and shifting of motors from foundation ; removal of shaft couplings; Dismantling of motors, thorough cleaning of motors (Cotton rags in scope of contractor), stator windings, rotor, fan and assembly components; Checking of defects in the dimantled stator and rotor, Replacement of DE and NDE side of motor by departmentally free issued bearings OR maintenance of old bearings as per the condition, baking of stator for IR and PI value improvement, Varnishing (varnish supply and apply in scope of contractor) if required, Application of Becktol Red(becktol supply and apply l in scope of contractor) on the windings ; Fitment of motors ; Painting of body, fan, covers of the motors (two coats of synthetic enamel paint after the proper surface preparation), Painting of Motor USI on body; Recording the electrical parameters post the overhauling (IR, PI, Inductance and Resistance); Conducting No Load test Trial in the manitanance bay and recording the No Load Current; Shifting of motors to the foundation; connection of power cables and space heater cables. No load Trial and direction check and marking of direction of the motors, making earthing connections. Disposing of old removed bearings to the central store asfter correct procedures is included in the scope. | ||||||
| 1.01 | Overhauling of AMW 355, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: - | 14 | Nos. | 40,000 ₹5,60,000 | 31,800 ₹4,45,200 | 31,000 ₹4,34,000 Lowest |
| 1.02 | Overhauling of AMW 315, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: - | 15 | Nos. | 34,000 ₹5,10,000 | 28,302 ₹4,24,530 | 27,700 ₹4,15,500 Lowest |
| 1.03 | Overhauling of AMW 280, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: - | 22 | Nos. | 32,000 ₹7,04,000 | 25,970 ₹5,71,340 | 24,500 ₹5,39,000 Lowest |
| 1.04 | Overhauling of AMW 250 , 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: - | 6 | Nos. | 27,000 ₹1,62,000 | 22,260 ₹1,33,560 | 21,000 ₹1,26,000 Lowest |
| 1.05 | Overhauling of AMW 225, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: - | 16 | Nos. | 22,500 ₹3,60,000 | 19,398 ₹3,10,368 | 18,300 ₹2,92,800 Lowest |
| 1.06 | Overhauling of AMW 200, M2BAX200, ND200, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: - | 16 | Nos. | 18,000 ₹2,88,000 | 16,536 ₹2,64,576 | 15,600 ₹2,49,600 Lowest |
| 1.07 | Overhauling of AMW 180, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: - | 6 | Nos. | 16,500 ₹99,000 | 14,310 ₹85,860 | 13,500 ₹81,000 Lowest |
| 1.08 | Overhauling of AMW 160 / AJ 160 / d 3A 160, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: - | 22 | Nos. | 15,000 ₹3,30,000 | 11,978 ₹2,63,516 | 11,300 ₹2,48,600 Lowest |
| 1.09 | Overhauling of AMW132 / 1LA2072-2 / d3A132, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: - | 30 | Nos. | 12,500 ₹3,75,000 | 10,282 ₹3,08,460 | 9,700 ₹2,91,000 Lowest |
Tender Value
₹40.2 L
EMD Value
₹80,421
Closing Date
30 Jul 2025, 3:00 pmClosed
GM, HWPK
GM Office, HWPK, Rawatbhata
Overhauling and Maintenance of different rating Three Phase Induction Motor of 415 V at HWP Kota during MTA 2025
2025_HWB_867647_1
HWPK/ELECT/2025/MTA 25/LT Motor/205
Open Tender
Electrical Works
Works
120 days
HWPK Site
As per Tender Docs
8 documents required · 8 mandatory
₹0
₹80,421
GM Office, HWPK
26 Sept 2025
9 Jul 2025
6 Aug 2025
9 Jul 2025
30 Jul 2025
11 Jul 2025
10 Jul 2025
Amount
Testing of motors and recording of IR values and other electrical parameters, Disconnection of power cables & space heater cables and earthing connections ; Rigging is under scope of contractor; Transportation and shifting of motors from foundation ; removal of shaft couplings; Dismantling of motors, thorough cleaning of motors (Cotton rags in scope of contractor), stator windings, rotor, fan and assembly components; Checking of defects in the dimantled stator and rotor, Replacement of DE and NDE side of motor by departmentally free issued bearings OR maintenance of old bearings as per the condition, baking of stator for IR and PI value improvement, Varnishing (varnish supply and apply in scope of contractor) if required, Application of Becktol Red(becktol supply and apply l in scope of contractor) on the windings ; Fitment of motors ; Painting of body, fan, covers of the motors (two coats of synthetic enamel paint after the proper surface preparation), Painting of Motor USI on body; Recording the electrical parameters post the overhauling (IR, PI, Inductance and Resistance); Conducting No Load test Trial in the manitanance bay and recording the No Load Current; Shifting of motors to the foundation; connection of power cables and space heater cables. No load Trial and direction check and marking of direction of the motors, making earthing connections. Disposing of old removed bearings to the central store asfter correct procedures is included in the scope.
Overhauling of AMW 355, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of AMW 315, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of AMW 280, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of AMW 250 , 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of AMW 225, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of AMW 200, M2BAX200, ND200, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of AMW 180, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of AMW 160 / AJ 160 / d 3A 160, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of AMW132 / 1LA2072-2 / d3A132, 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of AMW 112 , 100, 90, 80 2 pole / 4 pole frame size, 3 phase, 415 volt, NGEF or equivalent make motor: -
Overhauling of 1MJ3070-2-DA-93Z, 2 pole frame size, 0.37 KW, 3 phase, 415 volt, SIEMENS or equivalent make venting motor blower including balancing of all the impellers of the blower and its repairing
Metal filling in the bearing housing as per the requirement
Supply of Tap and Die Set consisting of M4x 0.5, M6x0.5, M8x0.75 & M8x1.0, M10 x 1.0 & M10 x 1.25, M12x1.0, M12x1.25, M12x1.5, M12x1.75, M16x1.0, M16 x 1.25, M16x1.5, M16x1.75, M16x2.0 with wrench handle, die handle, pitch gauge and plastic storage box
Servogem EP-3 Grease
Servogem EP-2 Grease
NEW INDIA ELECTRIC WORKS (BID ID -3257826)
VIJAYVARGIA ELECTRICALS (BID ID -3257780)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .