Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹33.8 LAccepted-AOC D NO 58 22 34 9 PYDIMAMBA NILAYAM BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | ₹33.8 L Quoted ₹33.9 L | l1 | Accepted-AOC Hence l1 |
| 2 | l3₹36.4 L+₹2.5 L (7.40%)Rejected-Finance D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | ₹36.4 L+₹2.5 L (7.40%) | l3 | Rejected-Finance Hence Rejected |
| 3 | l3₹46.4 L+₹12.6 L (37.1%)Rejected-Finance | ₹46.4 L+₹12.6 L (37.1%) | l3 | Rejected-Finance Hence Rejected |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
15 Dec 2020, 6:00 pmClosed
Nitin Ssarma
GE services vsp
Outsourcing Manning and Operation of EM installation ie Water treatment plant, 132kV and 11kV MRSS, DG Sets and RO Plant and comprehensive maint of RO Plant at NAOB V
2020_MES_371255_2
GE SERVICES TOKEN 04 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SERVICES
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
DGNP
₹80,000
Yes
11 Feb 2021
1 Dec 2020
16 Dec 2020
1 Dec 2020
15 Dec 2020
1 Dec 2020
1 Dec 2020 - 1 Dec 2020
Amount
Manning & Operation of 132kV MRS at NAOB Rambilli by providing the manpowers for each shift at round the clock are as under. (a) Electrical Engineer -01 No (detailed for General Shift) (b) Electrician (Skilled) - 01No (detailed for three Shift) (c) Helper (Semi-skilled) - 01 No (detailed for three Shift) The undermentioned plants/machinery to undertaken for supervision and maintaining the parameters. (a) 132kV Switchyard (b) 132kV Gas Insulated System (c) 10/16kVA Power Transformers - 02 Nos (d) SCADA system (e) Incoming/Outgoing HT switchgears (f) Stn Transforemer 500kVA - 01 No (g) Control and relay panels (h) Capacitor bank and APFC Panel Visual Cheking (a) All equipments/items to be visually checked by the operator and serviceability report to be filled in log sheet. Any fault or unserviceable of eqpts to be informed to Engineer/JE E/M otherwise EIC. Monitoring of Eqpts (a) Daily log sheet shall be maintained by the contractor & the log sheet shall be provided by the contractor as per Performa given by the department be inspected thoroughly before switching on. (b) Maintaining duty log sheet and checking all parameter of metering devices.
(c) Checking of various meters for measurement of current, voltage etc, including recording of these readings in log sheet and also recording of any unwanted signal of spark, sound in switchgears/eqpts etc. (d) Switchgear and equipments shall be properly cleaned. (e) 02 set of dress shall be provided for every shift operator (dress colour to be recovery of Rs 2000/- per person prior approval of Engr-in-Charge). (f) One basic mobile phone with sim to be provided at site for commnication and fault rectification. (g) Minor complaints to be attend by thetechnician given by the concerned JE/EIC. (h) Conveyance facility to be provided by the contractor in station premises for attending the faults/complaints. Note :- 1. Electrical/Engineer employed should have a valid Electrical license from state agency of 33 kv or above. 2. The rate shall be included for above said work Timing of shifts:- Ist Shift (0600 Hrs to 1400 Hrs (b) Electrician (Skilled) - 01No (c) Helper (Un skilled) - 02 Nos IInd Shift (1400 Hrs to 2200 Hrs (b) Electrician (Skilled) - 01No (c) Helper (Un skilled) - 02 Nos IIIrd Shift (2200 Hrs to 0600 Hrs (b) Electrician (Skilled) - 01No (c) Helper (Un skilled) - 02 Nos General Shift (0800 Hrs to 1600 Hrs)
Manning & Operation of 2.5 MLD Water treatment plant at NAOB Rambilli by providing the manpower for each shift at round the clock are as under. (a) FGM (Skilled) - 01No (detailed for three Shift) (b) Helper (Un-skilled) - 01 No (detailed for three Shift) The undermentioned plants/machinery to be undertaken for supervision and maintaining the parameters. (a) Inlet and outlet pumpsets for suction (raw water) and delivery (clear water) (b) Agitator tank (c) Chemical dosing pumps (d) Lamina clarifier (e) Clarified water tank (f) Multi grade filter (g) Active carbon filter (h) Control panel and SCADA Panel (i) Any other item part of the water treatment plant. Visual Cheking (a) All equipments/items to be visually checked by the operator and serviceability report to be filled in log sheet. Any fault or unserviceable of eqpts to be informed to JE E/M otherwise EIC. Monitoring of Eqpts (a) Daily log sheet shall be maintained by the contractor & the log sheet shall be provided by the contractor as per Performa given by the department be inspected thoroughly before switching on. (b) Maintaining duty log sheet and checking all parameter of metering devices.
(c) Checking of various meters for measurement of current, voltage etc, including recording of these readings in log sheet and also recording of any unwanted signal of spark, sound in switchgears/eqpts etc. (d) Switchgear and equipments shall be properly cleaned. (e) Dress shall be provided for every shift operator (dress colour to be approve prior approval of Engr-in-Charge). (f) One mobile phone with sim to be provided at site for commnication and fault rectification. (g) Minor complaints to be attend by the techanician given by the concerned JE/EIC. (h) Conveyance facility to be provided by the contractor in station premises for attending the fault/complaint. Note :- The rate shall be included for above said work. Timing of shifts:- Ist Shift (0600 Hrs to 1400 Hrs (a) FGM (Skilled) - 01No (b) Helper (Un-skilled) - 01 No IInd Shift (1400 Hrs to 2200 Hrs (a) FGM (Skilled) - 01No (b) Helper (Un-skilled) - 01 No IIIrd Shift (2200 Hrs to 0600 Hrs (a) FGM (Skilled) - 01No (b) Helper (Un-skilled) - 01 No
Manning and operation of E/M 11kv Sub station near MPC complex attending day to day electrical complaints given by the JE E/M for bldgs/watch towers/street light and perimeter lights for eight hours shift Note:- Nos of Person required - 02 persons 3 shift per day Ist shift (0600 Hrs to 1400 Hrs) = 01 Elect & 1 x Helper IInd shift (1400 Hrs to 2200 Hrs) = 01 Elect & 1 x Helper IIIrd shift (2200 Hrs to 0600 Hrs) = 01 Elect & 1 x Helper
Manning and operation of water supply pumps, DG Sets (160 kVA- 02Nos & 10 kVA- 01No) and RO Plant (600 LPH & 1000 LPH) at Rambilli premises by one FGM & one Helper including minor repair work to be carried out in pump house, RO Plant and DG sets by technician for eight hours shift (Pumping of raw water and treated water supply to be feed as per scheduled timing, DG Sets to operate during the main power supply building and technician to be maintained Reverse Osmosis based Desalisation plant, make- ROCHEM Separation systems and trouble free operation of the plant with correct quality of portable water discharge as per standred norms) Note:- No of Person required - 02 persons (01 FGM + 01 Helper) 3 shift per day Ist shift (0600 Hrs to 1400 Hrs) = 01 FGM & 01 Helper IInd shift (1400 Hrs to 2200 Hrs) = 01 FGM & 01 Helper IIIrd shift (2200 Hrs to 0600 Hrs) = 01 FGM & 01 Helper
Comprehensive Maint of RO plant, any capacity checking the function complete, descalling the membarines, active carbon filter, mechanical filters, replacing of O-Ring, seals, gland packing complete ensuring for the proper outlet quality of potable water complete all as specified and directed by Engr-in-Charge. Technician should be checking the RO Plant every 15 days (twice in a month) and serviceability report to be submitted Engr-in-Charge. Replacement of spares will be paid and measured separately.
Supply and fixing of spares and taking out unserviceable all as specified and directed by Engr-in-Charge. NOTE:- Replacement of any other spares other than the listed below (major/minor) if required shall be done by the contractor without any extra cost to the Govt. The list given below is not exhaustive and contractor has to ascertain the actual requirement of spares/ consumable as a contained by the sawcabing report as per item No 5 while quoting his rate. However contractor shall not have any further claim in this regard at a later stage.
Feed pump seal supply fix
Multiport valve supply fix
Pre filter supply fix
Carbon media supply fix
High pressure pump seal supply fix
Needle valve supply fix
Control panel supply fix
Sand media supply fix
Solenoid valve supply fix
Fuse for dosing pump supply fix
Filter Media per month supply fix
Activated carbon filter supply fix
Antiscalant for RO plant supply fix
Sodium Hypo Chloride supply fix
Food grade pH enhancer supply fix
Filter of 01 KLD 02 No and 02 KLD 01 No supply fix
Repair to RO plant 600 LPH by replacing of DT modules complete with all fitting and fixtures make : ROCHEM all as specified and diected by Engineer in charge.
Repair to RO plant 600 LPH Make - ROCHEM by Repair/replacing of HP motor pump, 1 HP capacity, complete with all fitting and fixtures make : ROCHEM all as specified and diected by Engineer in charge.
Repair to HP, three plunger reciprocating pump, 300/45 of 1000 LPH RO plant by replacing ceramic coating plunger,piston oil seal, oil gasket, gland ring, gland rope 6 mm dia, stuffing box gasket, valve spring, o ring, header block stud, nut & washers, lub oil and gland spring etc including testing complete all as specified and directed by engineer in charge.
Contractor to be provide Water Analysis of bore well/shallowl water as per IS: 10500 : 2012, Certified from Govt approved Lab . Parameters given are as under below :
(1.1) Chemical Analysis: (a) pH value (b) Electrical conductivity (c) Turbidity (d) TDS (e) TSS (f) Hard ness (g) Iron (h) Chlorides (j) Fluorides (k) Magnesium (l) Sulphate (m) Nitrate (n) Total alkalinity (o) Residual free chlorine (1.2) Chromium (Heavy metal in ground water) (1.3) Bacteriological parameters (a) Total Coliform (b) Faecal Coliform (c) E.Coli
MONITOR ENGINEERING WORKS
JAI ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .