Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC KOLLAM KERALA | PATHANAMTHITTA | KERALA | 689694 | L1 | Accepted-AOC AGREEMENT EXECUTED |
Tender Value
₹13.4 L
EMD Value
₹33,440
Closing Date
10 Aug 2020, 4:00 pmClosed
THE SUPERINTENDING ENGINEER
KOLLAM CORPORATION pin 691001
Construction of Vadakkevila Zonal Office -Electrical ,ELV and fire fighting works(Re-etender)
2020_LSGD_356896_2
PC6/12276/20
Open Tender
Electrical Works
Item Rate
120 days
KOLLAM CORPORATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,975
Yes
online
₹33,440
Yes
8 Dec 2021
3 Aug 2020
12 Aug 2020
3 Aug 2020
10 Aug 2020
3 Aug 2020
Amount
ELECTRICAL WORKS: Supply Installation testing and commissioning of 3 Phase 4 wire energy meter direct reading type and 63A HRC fuse with fuse link with enclosure complete with all other accessories as required.
Supply of 35 sqmm 3.5 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE
Supply of 10 sqmm 3 core PVC/XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE
90.11.1.11 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.6.6.4 Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
9.1.7 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)
9.1.21 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 35 sq. mm (32mm)
7.3.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm
7.7.1 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
7.8.1 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.55.3 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet
1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
90.2.1.6 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
1.24.8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
90.11.1.12 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
90.11.1.20 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCCB/Isolator/RCCB/RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.. double pole
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing 40 A to 63 A, TPN MCB (C curve), 10 kA breaking capacity in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Supplying and laying 6 SWG Copper wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
Supply & Installation of 250 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Supply, installation, testing and commissioning of 5W LED wall light with output of 500 lumen for use on 230 V AC supply in batten/ angle holder including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
1.14.9 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supply, installation, testing and commissioning of 10W LED bulk head light fitting with 1000 lumen output working on 230V AC directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
90.3.19.3 upply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
90.4.5.2 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
Supply, installation, testing and commissioning of Starter panel for submersible pumps 1.5kW x 2 nos (working & standby) with electrical interlock, complete with all other accessories as required.
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
4.1.3 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.225 mm width X 50 mm depth X 1.6 mm thickness
ELV WORKS : SITC Of Network Video Recorder: Providing & fixing Network Video Recorde 8-channel high definition network video input and storage Support simultaneous HDMI and VGA output, resolution up to 1920�1080P/60Hz Supports 256Mbps bandwidth throughput handling, Supports 4-channel, 1080P video real-time decoding and synchronous playback Supports 8 SATA hard disk with capacity up to 4TB.
Supply, installation, testing and commissioning of Outdoor IR IP bullet camera 2 MP 2.1mm/4mm/6mm focal length lens capable to 1.0 lux sensitivity,with IR 480TV lines.
Supply, installation, testing and commissioning of indoor IR IP dome camera 2 MP 2.1mm/4mm/6mm focal length lens capable to 1.0 lux sensitivity, with IR n 480 TV lines.
Supply, installation, testing and commissioning of Cat6 I/O for Patch Panel Shuttered.
Supply, Installation, testing and commissioning of Cat6 16 Port un loaded Patch Panel.
Supply, installation, testing and commissioning of 16 Port 10/100/1000 Mbps PoE Switch.
Supply Installation testing and Commissioning of 10/100/1000 Mbps 24 Port Network Switch to provide networks and internet on office places etc.
Supply and laying of Cat6 outdoor cable including necessary connectors
Supply, installation, testing and commissioning of 24" Monitor for CCTV
Supply and drawing of CAT 6 4 pair cable including all necessary connector.
Supply, Installation, Testing and commissioning Of distribution box for CCTV 6Ux600Wx600D With Front Glass Door,Side Openable Panels with Lock & Key,4Way 5A PDU,1U Cable Manager,Cooling Fan,H/W Kit10
Supply, installation, testing and commissioning of wall mounted 15Ux600Wx600D With Front Glass Door With Lock & Key,Side Openable Panels with Lock & Key,6Way 5A PDU,1U Cable Manager,Cooling Fan,H/W Kit10
Supply, installation, testing and commissioning of wifi router without modem (Brand - D-link) complete with all other accessories as required.
Supply, installation, testing and commissioning of 16W wall mount speaker 86db/W
Supply & laying of twin twisted 2x1.5 sqmm Cu flexible wire 1.1 kv grade PVC insulated through PVC conduit.
Supply, Installation, Testing and commissioning of XLR cables and connectors
SITC Of 350W RMS MIXER AMPLIFIER, 3 MIC, 2 AUX, 100V/70V AND 4OHMS , BALANCED MIC,FREQUENCY RESPONSE (50 HZ-16000HZ),S/N RATIO-MIC1,2,3,4:66DB;AUX 1:80 DB,THD-LESS THAN 1% AT 1 KHZ,1/3 RATED POWER, MUTING FUNCTION-MIC 1 OVERRIDES OTHER INPUT SIGNALS WITH 0-30 DB ATTENUATION,CONTROLS-INDIVIDUAL GAIN CONTROLS, POWER SWITCH;BASS: 10DB AT 100HZ,TREBLE: 10DB AT10000HZ.
Supply, installation, testing and commissioning of Telephone socket.
Supply,Installation, Testing & commissioning of Telephone of approved makes including all other accessories for connection.
Supply & Installation of telephone cable 10 pair through PVC conduit.
Supply, installation, testing and commissioning of 20 PAIR BOX WITH KRONE MODULES
Supply, installation, testing and commissioning of Telephone system: NEC Digital Key Telephone System Model-SL2100 32 Bit Micro Processor Configured as 08 P&T lines 48 Hybrid Ports EXPANDABLE MODEL UP TO 128 PCM/TDM 100 % Non-Blocking Inbuilt Conference,32 party Auto attendant (single channel) CLI based call routing AND ALL STANDARD FEATURES
Supply, installation, testing and commissioning of LAN socket.
Supply and installation of GI box for modular switch installation including base plate and front plate 1/2 M
1.18.2 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
1.18.3 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 Pair
FIRE FIGHTING SYSTEM FOR MAIN BUILDING : Providing and fixing FIRE DUCT Signage
Providing and fixing Escape Route EXIT Signage
Providing and fixing FIRE EXIT Signage
FIRE FIGHTING WORKS Providing and fixing 4 kg DCP Type Extinguisher
Providing and fixing CO2 type fire extinguishers
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .