| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC | ₹37.1 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹38.9 LRejected-AOC | ₹38.9 L | L2 | Rejected-AOC 2nd Lowest Bidder |
| Sl No | Description | Qty | Unit | HIRENDRA SEKHAR CHAKRABORTY L1 | MRINAL KANTI ACHARJEE L2 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil. | 21.71 | cum | 286.85 ₹6,226.65 | 300 ₹6,512.10 |
| 2.00 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work up to plinthlevel :
4.1.2 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources | 8.21 | cum | 7,783.65 ₹63,864.85 | 8,000 ₹65,640 |
| 3.00 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work up to plinthlevel :
4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) | 7.51 | cum | 6,833.4 ₹51,332.50 | 7,000 ₹52,584 |
| 4.00 | Centering and shuttering including strutting, propping etc. and removal of form for :
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts | 78.3 | sqm | 804.25 ₹62,972.77 | 850 ₹66,555 |
| 5.00 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
10.16.1 Hot finished welded type tubes | 14,515.47 | kg | 154.9 ₹22.5 L | 167 ₹24.2 L |
| 6.00 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m² | 760.14 | sqm | 978 ₹7.4 L | 978 ₹7.4 L |
| 7.00 | Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimetre:
12.3.3 0.63 mm thick | 225.6 | Metre | 441.6 ₹99,624.96 | 441.6 ₹99,624.96 |
| 8.00 | Cantering and shuttering including strutting, propping etc. and removal of form for :
5.9.2 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc | 75.12 | sqm | 669.55 ₹50,296.60 | 669.55 ₹50,296.60 |
| 9.00 | Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. :
12.38.1 100 mm diameter | 64 | Each | 308.45 ₹19,740.80 | 350 ₹22,400 |
| 10.00 | Providing and fixing on wall face un plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
12.41.2 110 mm diameter | 323.4 | Metre | 319.75 ₹1.0 L | 319.75 ₹1.0 L |
Tender Value
₹37.1 L
EMD Value
₹74,168
Closing Date
9 Mar 2026, 2:00 pmClosed
SE PWD Silchar Building Circle Silchar
SE PWD Silchar Building Circle Silchar
Civil, Sanitary and Water supply and Electrical Work and Road Work
2026_PWBNH_51257_1
SBC/CS/2025-26/10/638/Gr-II
Open Tender
Civil Works - Building
180 days
Sadarghat, Silchar
As per NIT
5 documents required · 5 mandatory
₹1,000
₹74,168
Yes
SE PWD Silchar Building Circle Silchar
8 May 2026
17 Feb 2026
9 Mar 2026
17 Feb 2026
9 Mar 2026
17 Feb 2026
17 Feb 2026 - 9 Mar 2026
26 Feb 2026
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work up to plinthlevel : 4.1.2 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - All work up to plinthlevel : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimetre: 12.3.3 0.63 mm thick
Cantering and shuttering including strutting, propping etc. and removal of form for : 5.9.2 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 12.38.1 100 mm diameter
Providing and fixing on wall face un plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 12.41.2 110 mm diameter
Providing and fixing on wall face un plasticised - PVC moulded fittings / accessories for un plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12.42.3 Single tee with door 12.42.3.2 110x110x110 mm
Providing and fixing on wall face un plasticised - PVC moulded fittings / accessories for un plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12.42.4 Single tee without door 42.4.2 110x110x110 mm
Providing and fixing on wall face un plasticised - PVC moulded fittings / accessories for un plasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 12.42.5 Bend 87.5° 12.42.5.2 110 mm bend
15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 16.91.2 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
Applying priming coat: 13.50.2 With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 13.61.1 Two or more coats on new work
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.39 MB
Tendernotice_2.pdf
PDF • 0.65 MB
BOQ_81455.xls
BOQ • 0.29 MB
FOB.pdf
Additional Documents • 0.17 MB
Download all tender documents and submit your bid