| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC | ₹41.4 L | L1 | Accepted-AOC Competent committee approved the tender in favour of Ist Lowest Bidder |
| 2 | L2₹45.0 L+₹3.5 L (8.55%)Rejected-AOC | ₹45.0 L+₹3.5 L (8.55%) | L2 | Rejected-AOC Competent committee rejected the file due to higher rates |
| 3 | L3₹45.9 L+₹4.5 L (10.8%)Rejected-AOC | ₹45.9 L+₹4.5 L (10.8%) | L3 | Rejected-AOC Competent committee rejected the file due to higher rates |
| Sl No | Description | Qty | Unit | M/S MEGHA ENTERPRISES L3 | M/S SUPER ENGINEERING TRADERS L2 | CLUSTER TRANSFORMERS & SWITCHGEAR L1 |
|---|---|---|---|---|---|---|
| 1.00The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-Shahjhanpu Road, Bareilly Approx. distance upto 100 Km. Including safe loading and unloading. | ||||||
| 1.01 | 11/0.4 KV 3 Phase 250 KVA T/F | 32 | Nos. | 4,000 ₹1,28,000 | 3,900 ₹1,24,800 | 3,500 ₹1,12,000 Lowest |
| 1.02 | LT Cable 1x400 sqmm | 1,280 | Mtr | 4 ₹5,120 | 20 ₹25,600 | 3 ₹3,840 Lowest |
| 1.03 | Other Line material i.e., 33 KV & 11 KV pin insulater/stay/earthing complete/Disc Fitting/Disc Insulators/Dropper Channel/Crossing Bracing/ Top Channel/Binding Wire/Danger Board/Barbed Wire/numberplate/stone pad/Control Cable etc | 32 | Qtl | 300 ₹9,600 | 250 ₹8,000 Lowest | 350 ₹11,200 |
| 2.00 | Construction of T/F plinth 2x2x1 m3 or Minimum 4 Cubic Meter (As per Site Requirement) for mounting 250 KVA T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect | 32 | Nos | 20,000 ₹6,40,000 | 26,000 ₹8,32,000 | 19,521.19 ₹6,24,678.08 Lowest |
| 3.00 | Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) or Minimum 200 Sq Feet (As per Site Requirement)by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation. | 32 | Nos | 28,000 ₹8,96,000 | 24,500 ₹7,84,000 Lowest | 25,000 ₹8,00,000 |
| 4.00 | Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5 m length is inserted at the bottom. Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work Contractor will provide all material, Manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE) | 64 | Job | 12,500 ₹8,00,000 | 8,500 ₹5,44,000 Lowest | 12,500 ₹8,00,000 |
| 5.00 | Dismentaling of 100 KVA Transformer as per norms complete in all respect | 31 | Nos | 4,000 ₹1,24,000 | 2,700 ₹83,700 Lowest | 3,500 ₹1,08,500 |
| 6.00 | Dismentaling of 160 KVA Transformer as per norms complete in all respect | 1 | Nos | 4,500 ₹4,500 | 2,900 ₹2,900 Lowest | 4,000 ₹4,000 |
| 7.00 | Mounting of 250 KVA T/F Transformers as per norms complete in all respect - | 32 | Nos | 6,000 ₹1,92,000 | 5,700 ₹1,82,400 | 4,500 ₹1,44,000 Lowest |
Tender Value
₹46.1 L
EMD Value
₹46,052
Closing Date
8 Jun 2026, 5:00 pmClosed
SUPERINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE, KATJU MARG, BAREILLY
For Increasing Capacity of Existing Distribution Transformer under Business Plan 2026-27 scheme Under EDD- Shahjhanpur Road, Bareilly
2026_MVVNL_1152740_1
08/EDCB/2026-27
Open Tender
Electrical Works
Item Rate
30 days
WORK
AS PER TENDER FORM
3 documents required · 3 mandatory
₹3,540
SE,EDC
₹46,052
11 Aug 2026
24 May 2026
9 Jun 2026
24 May 2026
8 Jun 2026
24 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-Shahjhanpu Road, Bareilly Approx. distance upto 100 Km. Including safe loading and unloading. | |||||
| 1.01 | 11/0.4 KV 3 Phase 250 KVA T/F | 32 | Nos. | - | - |
| 1.02 | LT Cable 1x400 sqmm | 1,280 | Mtr | - | - |
| 1.03 | Other Line material i.e., 33 KV & 11 KV pin insulater/stay/earthing complete/Disc Fitting/Disc Insulators/Dropper Channel/Crossing Bracing/ Top Channel/Binding Wire/Danger Board/Barbed Wire/numberplate/stone pad/Control Cable etc | 32 | Qtl | - | - |
| 2 | Construction of T/F plinth 2x2x1 m3 or Minimum 4 Cubic Meter (As per Site Requirement) for mounting 250 KVA T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect | 32 | Nos | - | - |
| 3 | Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5'(L)x5'(W)x8’(H) or Minimum 200 Sq Feet (As per Site Requirement)by strenghtening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation. | 32 | Nos | - | - |
| 4 | Pipe Earthing of Transformer (By boring of 4 inch diameter 20 m deep, 40 mm diameter A class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5 m length is inserted at the bottom. Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work Contractor will provide all material, Manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE) | 64 | Job | - | - |
| 5 | Dismentaling of 100 KVA Transformer as per norms complete in all respect | 31 | Nos | - | - |
| 6 | Dismentaling of 160 KVA Transformer as per norms complete in all respect | 1 | Nos | - | - |
| 7 | Mounting of 250 KVA T/F Transformers as per norms complete in all respect - | 32 | Nos | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
Tender_form.pdf
Tender Documents • 1.27 MB
BOQ_2159463.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .