Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-Finance | L1 | Accepted-Finance Accept | |
| 2 | L2₹3.0 L+₹44,266 (17.6%)Accepted-Finance | L2 | Accepted-Finance Accept | |
| 3 | L3₹3.3 L+₹78,666 (31.3%)Accepted-Finance | L3 | Accepted-Finance Accept |
| Sl No | Description | Qty | Unit | G KUMAR L1 | DN CONTRACTORS L2 | SM ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commissioning of Hiwall-Mounted Chilled Water Fan Coil Unit (FCU), 2 TR Capacity.
Supply and fixing of Hiwall-mounted chilled water fan coil unit (FCU) of 2 TR capacity, including all required accessories and works for proper installation and operation. The unit shall include the following features and specifications:
i. Cooling Coil: Constructed with copper tubes and aluminium fins, factory-tested for performance and durability.
ii. Casing: High-grade powder-coated metal or ABS plastic body with anti-corrosive treatment.
iii. Air Flow: Designed for wall-mounted applications with low-noise, high-efficiency operation.
iv. Control: Compatible with manual thermostats or Building Management System (BMS), as applicable.
v. Drainage: Integrated condensate drain tray with outlet provision for proper drainage.
vi. Mounting: Wall-mounted using appropriate brackets/supports and vibration isolators.
vii. Connections:
a. Water Inlet/Outlet: Suitable for integration with existing chilled water piping network.
b. Electrical: 230V, 50Hz single-phase power supply for fan motor.
viii. Accessories: Washable air filters, flexible hose connections, and all necessary mounting hardware.
ix. Testing & Commissioning: Includes pressure testing of the coil, water flow balancing, and functional testing to validate cooling performance.
All materials and workmanship shall conform to standard specifications and CPWD-approved makes. The scope includes complete installation, including required fittings and supports, and commissioning of the system as per site conditions. | 2 | Nos | 21,110 ₹42,220 | 59,000 ₹1,18,000 | 20,000 ₹40,000 Lowest |
| 2.00 | Supply and Fixing of Copper Pipe from Existing MS Pipe to Indoor Unit (Approx. 16 Mtr, 5/8" – 2 Runs per IDU) including all necessary fittings such as bends, couplings, reducers, elbows, unions, clamps, supports, and hangers, etc., complete as per standard specification.
(CPWD-approved makes) | 2 | Nos | 16,198 ₹32,396 | 15,000 ₹30,000 Lowest | 15,000 ₹30,000 Lowest |
| 3.00 | Supply and Fixing of Solenoid Valve with Accessories, etc., complete as per standard specification. (Solenoid valve suitable for HVAC applications with coil voltage as per site specifications (230V AC/24V DC))
(CPWD-approved makes) | 2 | Nos | 5,625 ₹11,250 | 3,800 ₹7,600 Lowest | 15,000 ₹30,000 |
| 4.00 | Supply and Fixing of 5/8” Ball Valve with MS Fittings, etc., complete as per standard specification.
(Ball valve bodies made of brass or stainless steel)
( CPWD-approved brand) | 2 | Nos | 4,535 ₹9,070 | 2,000 ₹4,000 Lowest | 15,000 ₹30,000 |
| 5.00 | SITC of 2.0 Ton A/C, 5 Star Rating of BEE (Inverter) Split Type Air Conditioners complete with indoor unit (IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant (R32) piping with insulation (EP Foam pipe section) up to 3 Mtr. (IDU to ODU) copper power cable up (Evaporator and Condenser) to 4 Mtr. (at least 3CX 2.5 Sqmm, PVC Insulation, FRLS copper wire) (IDU to ODU), R-32 Refrigerant, PVC drain pipe (dia 15mm) Remote, suitable for 400/230V +10%, 50 Hz, 1/3 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ reciprocating/ rotary compressor, with ODU Stand, stabilizer including civil works. Complete as per the standard specification.
(CPWD-approved brand) | 2 | Job | 78,199 ₹1,56,398 | 68,000 ₹1,36,000 Lowest | 1,00,000 ₹2,00,000 |
Tender Value
₹3 L
Closing Date
1 Sept 2025, 5:00 pmClosed
Director
IIM Tiruchirappalli Trichy to Pudukkottai Main Road, Trichy - 620 024
Supply and Installation of Air Conditioning Facility in UPS Rooms at the Administrative and Academic Blocks of IIM Tiruchirappalli
2025_IIMT_873146_1
25SP143T
Open Tender
Electrical Works
Works
15 days
IIM Tiruchirappalli
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
29 Sept 2025
13 Aug 2025
3 Sept 2025
13 Aug 2025
1 Sept 2025
13 Aug 2025
Amount
Supply, Installation, Testing & Commissioning of Hiwall-Mounted Chilled Water Fan Coil Unit (FCU), 2 TR Capacity. Supply and fixing of Hiwall-mounted chilled water fan coil unit (FCU) of 2 TR capacity, including all required accessories and works for proper installation and operation. The unit shall include the following features and specifications: i. Cooling Coil: Constructed with copper tubes and aluminium fins, factory-tested for performance and durability. ii. Casing: High-grade powder-coated metal or ABS plastic body with anti-corrosive treatment. iii. Air Flow: Designed for wall-mounted applications with low-noise, high-efficiency operation. iv. Control: Compatible with manual thermostats or Building Management System (BMS), as applicable. v. Drainage: Integrated condensate drain tray with outlet provision for proper drainage. vi. Mounting: Wall-mounted using appropriate brackets/supports and vibration isolators. vii. Connections: a. Water Inlet/Outlet: Suitable for integration with existing chilled water piping network. b. Electrical: 230V, 50Hz single-phase power supply for fan motor. viii. Accessories: Washable air filters, flexible hose connections, and all necessary mounting hardware. ix. Testing & Commissioning: Includes pressure testing of the coil, water flow balancing, and functional testing to validate cooling performance. All materials and workmanship shall conform to standard specifications and CPWD-approved makes. The scope includes complete installation, including required fittings and supports, and commissioning of the system as per site conditions.
Supply and Fixing of Copper Pipe from Existing MS Pipe to Indoor Unit (Approx. 16 Mtr, 5/8" – 2 Runs per IDU) including all necessary fittings such as bends, couplings, reducers, elbows, unions, clamps, supports, and hangers, etc., complete as per standard specification. (CPWD-approved makes)
Supply and Fixing of Solenoid Valve with Accessories, etc., complete as per standard specification. (Solenoid valve suitable for HVAC applications with coil voltage as per site specifications (230V AC/24V DC)) (CPWD-approved makes)
Supply and Fixing of 5/8” Ball Valve with MS Fittings, etc., complete as per standard specification. (Ball valve bodies made of brass or stainless steel) ( CPWD-approved brand)
SITC of 2.0 Ton A/C, 5 Star Rating of BEE (Inverter) Split Type Air Conditioners complete with indoor unit (IDU), Outdoor unit (ODU), surface / concealed copper Refrigerant (R32) piping with insulation (EP Foam pipe section) up to 3 Mtr. (IDU to ODU) copper power cable up (Evaporator and Condenser) to 4 Mtr. (at least 3CX 2.5 Sqmm, PVC Insulation, FRLS copper wire) (IDU to ODU), R-32 Refrigerant, PVC drain pipe (dia 15mm) Remote, suitable for 400/230V +10%, 50 Hz, 1/3 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with scroll/ reciprocating/ rotary compressor, with ODU Stand, stabilizer including civil works. Complete as per the standard specification. (CPWD-approved brand)
DN CONTRACTORS (BID ID -3271113)
SM ENTERPRISES (BID ID -3274784)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_917879.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .