| Sl No | Description | Qty | Unit | Medsynaptic Pvt Ltd L1 | Everrtech Software Pvt. Ltd. L2 |
|---|---|---|---|---|---|
| 1.00 | Picture Archival and Communication System with Radiology Information System (RIS-PACS) | 1 | Nos | 54,50,000 ₹8.7 Cr | 61,00,000 ₹8.8 Cr |
| 2.00 | Advance 3D visualisation with hardware | 2 | Nos | 49,05,000 - | 45,00,000 - |
| 3.00 | 2 U rack server with high availability | 2 | Nos | 9,81,000 - | 9,14,200 - |
| 4.00 | AD Server | 1 | Nos | 5,45,000 - | 7,96,000 - |
| 5.00 | SAN Storage | 1 | Nos | 9,81,000 - | 10,19,183 - |
| 6.00 | NAS Storage | 1 | Nos | 16,89,500 - | 28,55,000 - |
| 7.00 | Storage at DR Site | 1 | Nos | 16,89,500 - | 28,55,000 - |
| 8.00 | Radiology Workstation without monitor | 20 | Nos | 1,19,900 - | 2,03,000 - |
| 9.00 | PACS Workstation diagnostic 6 MP 30" monitor | 3 | Nos | 6,81,250 - | 4,75,000 - |
| 10.00 | PACS Workstation diagnostic 5 MP 21" monochrome monitor | 2 | Nos | 5,45,000 - | 4,30,000 - |
Tender Value
₹9.3 Cr
EMD Value
₹5 L
Closing Date
16 Dec 2024, 5:00 pmClosed
Managing Director
Kerala Medical Services Corporation Limited
Picture Archiving and Communication Systems (PACS)
2024_KMSCL_706934_1
KMSCL/EP/557(R)/2024
Open Tender
Equipments
126 days
Kerala Medical Services Corporation Limited
Please refer Tender documents.
28 documents required · 28 mandatory
₹29,500
Yes
₹5 L
Yes
6 Apr 2026
19 Nov 2024
18 Dec 2024
19 Nov 2024
16 Dec 2024
19 Nov 2024
Picture Archival and Communication System with Radiology Information System (RIS-PACS)
Advance 3D visualisation with hardware
2 U rack server with high availability
AD Server
SAN Storage
NAS Storage
Storage at DR Site
Radiology Workstation without monitor
PACS Workstation diagnostic 6 MP 30" monitor
PACS Workstation diagnostic 5 MP 21" monochrome monitor
PACS Workstation diagnostic 12 MP 31" monitor
PACS Workstation diagnostic 3 MP 21" monitor
PACS Workstation diagnostic 2 MP 21" monitor
24" Clinical review monitor
Desktop Computer for Viewing station
All in one computer for viewing station
VR Server hardware
Speech Mic
Firewall with min 400 concurrent support
20KVA UPS with 60 minutes back up
20KVA UPS with 15 minutes back up
10 KVA UPS with 30 minutes back up
CD DVD publisher
Film Digitizer
600 VA UPS with 15 minutes back up
Regular printer
Heavy Duty laser Multifunctional A3
Core Switch 24 port
Unmanaged switch 24 port
Secure tunneling SF Server
Core router
KVM Switch
Supply and Lying of UTP 4 pair CAT 6E LAN Cable (per Mtr) - Molex Part No : CAA-00076
Supply and Lying of UTP 4 pair CAT 6A LAN Cable (per Mtr) - Molex Part No : CAA-00076
Supply of CAT6E 2 mtr long Patch cord factory crimped on both sides. Molex : Part No : PCD-02003-0H
Supply of CAT6E 1 mtr long Patch cord factory crimped on both sides. Molex : Part No : PCD-02001-0H
Supply of Cat6 24 Port Modular Loaded patch Panel loaded with Ios. Molex - Part No : PID-00076, KSJ-00018-BL
Supply of Information outlets with faceplates and back Box . Molex Part No : KSJ-00018-BL, WSY-00012-02 (Back box unbranded ) Single Port
Central Loose Tube Armored Outdoor Cable, Single mode, OS2, 6-fibers
12U wall Rack with cooling fan, PDU, Cable manager
SM OS2 Patch Cord, 3m OFC
12/24 Port LIU SM Fully Loaded
10GBASE SFB+ Modules
Rack mount power manager dual bank
50 x 38 mm CMS with base and lid
50 x 50 mm CMS with base and lid
Supply of GI Perforated Tray Size:250x50x1.6mm for lying OFC from Server Room to Causality with supporting accessories
42U rack with cooling fan, PDU, Cable manager
24U rack with cooling fan, PDU, Cable manager
Wifi access point
Fiber booster
6U Rack with cooling fan, PDU, Cable manager
9U Rack with cooling fan, PDU, Cable manager
Supplying and fixing following way, Three pole and neutral, sheet steel, MCB distribution board, 240 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.4way V DB 4 Way VDB - KSEB Power For Smart rack/2Tr AC-to be installed in the server Room
Supply and Fixing of 125A 4-poleMCCB
Supply and fixing 80A 3P MCB rating, 240/415 V, 10 kA, C-curve for Smart cabinet for server
Supply and fixing 32A 3P MCB rating, 240/415 V, 10 kA, C-curve for Server Room AC
Supply and fixing 80A 3P MCB rating, 240/415 V, 10 kA, C-curve to be installed with in 3 mtr of Smart Rack with suitable enclosure
4way TPN DB -UPS Power -Supplying and fixing following way, Three pole and neutral, sheet steel, MCB distribution board, 240 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.4way TPN DB
63A, 4-pole ISOLATOR
10/16A rating, 240/415 V, 10 kA, C-curve, single pole MCB conforming to IS/IEC: 60898 in the existing panel assembly complete with connections, testing, commissioning etc
Supply and drawing the following sizes of ISI marked 1.1 kV grade PVC insulated stranded single core FR LS copper conductor cables conforming to IS: 694 Part-1 (2010) in the existing surface / recess conduit including giving necessary connections etc as required. 4core 35 Sqmm Copper Flexible cable From Electrical panel to 4way VDB(Server Room)
4core 25 Sqmm Copper Flexible Cable from 4way VDB(Server Room) to Smart Cabinet
4 core 6 Sqmm Copper Flexible cable -Server Room AC
1 core 25Sqmm Copper Flexible Cable for Smart cabinete Earth Connection from Earth Bench
Supply & Laying 2 runs 2.5 + 1run x 1.5 sq.mm. Cu conductor PVC insulated wires through PVC conduits for Circuit & looping
2x6/16Amps Socket with switch (Modular type with back box)6M EOC Room/Monitoring Room
1x6/16Amps Socket with switch (Modular type with back box)3M EOC Room/Monitoring Room
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC: 61084 / BS: 476 and 4678 on surface / in recess including cutting the wall and making good the damages in case of recessed installation as required. 50 x 50 mm CMS with base and lid
Joint cover
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC: 61084 / BS: 476 and 4678 on surface / in recess including cutting the wall and making good the damages in case of recessed installation as required. 100 x 50 mm CMS with base and lid
Internal Angle
External Angle
Flat Angle 90°.
Joint cover.
End Cap.
25mm dia
32mm dia
Supply and providing Copper Plate Earthing as per IS: 3043 with 600 x 600 x 6 mm copper earth plate, 20 mm 2.7 metre long GI watering pipe with drilled holes and fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh at the top, filling with required quantity of charcoal, salt, chemical compound etc including providing masonry enclosure with cover plate having locking arrangement and the construction of inspection chamber shall be with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint and earth continuity conductor to the plate (in ordinary soil).
Supply and providing test joint for the earthing system using 2 numbers of the following size of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm tinned copper strip
Supply and providing earth lead from the test joint to the earth electrode using the following size of conductors / strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate, test joint etc as required. 25 x 3 mm copper strip tinned at the points of contacts.
ABC Powder Type Fire Extinguisher With NABL Approval, Fights Class A, B, C and Electrically started fires. 2 kgs
Automatic Timer for split AC (Only change over)
90.11.1.11 Supply and installation of sheetsteel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, arth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the amages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.12 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
90.11.1.18 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.7 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2 + 8 way, Double door
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.13.3 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.2 Supplying and fixing following Erating four pole (three Providing and laying 2 mm thick anti static Poly vinyl flooring of laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete.phansiesaantd neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Wiring & ELV 1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.31 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.2 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
od153401/2024_2025 CAT 6 RJ 45 Computer jack modular SOCKET OUTLET
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
1.53.2 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required2 run of Cable
1.53.3 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required3 run of Cable
90.6.9.2 Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit2 pair
4.6.1 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.6.2 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.7.1 Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray "bends " ( galvanisation not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.7.2 Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray "bends " ( galvanisation not less than 50 microns) with perforation notmore than 17.5%, in convenient sections, joined with connectors, suspended fromthe ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm widthX50mmdepthX1.6mmthickness
4.8.1 Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray "Tee" ( galvanisation not less than 50 microns) with perforation not morethan 17.5%, in convenient sections, joined with connectors, suspended from theceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.8.2 Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray "Tee" ( galvanisation not less than 50 microns) with perforation not morethan 17.5%, in convenient sections, joined with connectors, suspended from theceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
4.9.1 Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray ?Cross member? ( galvanisation not less than 50 microns) with perforationnot more than 17.5%, in convenient sections, joined with connectors, suspendedfrom the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
4.9.2 Supplying and installing following size of perforated Hot Dipped Galvanised Ironcable tray ?Cross member? ( galvanisation not less than 50 microns) with perforationnot more than 17.5%, in convenient sections, joined with connectors, suspendedfrom the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
Air Conditioning od153619/2024_2025 4 KVA Voltage Stabilizer Wall mount type with Time delay, High& low voltage& Thermal overload protection, Input voltage: 170-220V, Output Voltage : 200-240V, High Voltage Cut Off : 240V, Efficiency: >95%, Frequency : 50Hz, V guard VG 400 or Equivalent
od153620/2024_2025 Supply, Conveyance testing and commissioning of 2 Ton 5 Star Inverter Type, split AC unit with Copper Tube cooling coils, 5 star rating Bluestar/LG(Dual Inverter Type)/Voltas/Mitsubishi or Superior Superior brands, Cooling Capacity 6000 KW/hr with rotary/scroll type compressors. with microprocessor controlled code less remote, CFM above 500/450, LED/LCD Display
od153621/2024_2025 Core Cutting charges including Making the surface finished with plastering and painting, making good and finishing with matching surface after housing pipe etc.
od153622/2024_2025 Copper Pipe with Superlon Insulation for Suction and Discharge
od153623/2024_2025 PVC Drain Pipe with proper insulation
od153624/2024_2025 Weather Proof 3 Core Copper Wire for Indoor to Outdoor Connecting Cable (Size as per the requirement of AC manufacturer)
od153632/2024_2025 Supporting Stand for Fixing Outdoor Unit(Powder coated)
Civil Partition work 21.1.1.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangleAluminniumsnap beadingforglazngpaneling, C.P. brass/ stainless steel screws, all completeas per architectural drawingsand the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron )
21.2.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
21.3.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
21.4.2 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With brass cover plate minimum 1.25 mm thickness
21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in- charge ( Door handle, lock and stopper etc to be paid separately)
50.9.11.2 Providing and fixing Thomson Multi wood board or equivalent make paneling 18 mm thick to fame,backing or studding with screws etc pletei(Frames backiing or studding to be paid separately)as per the direction of site Engineer-in-charge.
9.76 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
9.74.2 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:200x10 mm
9.81.1 Providing and fixing bright finished brass handles with screws etc. complete:125 mm
9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
12.52.1 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mmethickwithi8mmedirop madegof GIisheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending
Furniture work od154392/2024_2025 Computer Chair The Medium Back Adjustable Revolving chair made with Mesh back within Built Handle in the Nylon Finish, The Back is designed extra lumber support. The seat have provided Seat cover in PP made with 12mm hot pressed ply and PU Moylded foam. The tilting mechanism should be synchro-tilt mechanism as per international ergonomics standards any position locking. The base and pin wheels are made in the Nylon. 120mm H Gas lift should be provided with Tower Bellow
od154393/2024_2025 High Back Chair Made with feather Foam Seat & Mesh Back with lumber support. , The Gas lift mechanism should be tested as per BIFMA X 05.01.2002 Standards. The pedestal should be five legged injection moulded in black 30% glass –filled nylon and fitted with 5 nos twin wheel castors. The castors of the chairs should be glass filled, It should have synchro any angle locking arrangement
od155050/2024_2025 CPU Trollly The unit shall be of 240mm high with adjustable width from 220 to 320mm made of minimum 2.0mm thick CRCA Steel sheet grade A as per IS 513 epoxy powder coated of minimum 50 micron thickness having high density at 70-75 Kg/Cum cross linked polythelene foam spacers of 8mm thick and 2 nos lockable castors and 2Nos non lockable castors
od155051/2024_2025 Work station Table: Supplying and fixing standard work station table 1.Work station table top Will be in single piece made up of Prelaminated Particle Board. 2.The Work station table top shall be made of 25mm thick Interior Grade-I conforming to IS 12823 prelaminated particle board with 2 mm thick hot melt PVC edge banding .3.The Work station table top shall be fixed in side Partition 4.Key Board Tray; Metal keyboard tray with mouse pad to be considered. The key board drawer should move on telescopic channels for smooth operation and shall be fixed below the table for smooth movement. 5.The length & Width of table top to varies as per site measurement .So the Area of table to be measured in Sqm.
od155053/2024_2025 PEDESTAL Pedestal of size 400(W) X 450(D) X 680(H) Top drawer should have a stationary tray made of 18mm thick Pre-laminated Particle board of Interior Grade-I conforming to IS 12823 having three drawer configuration, two for personal and one for lateral files. The drawer of pedestal shall be made of Particle board finished with laminate of approved colour shade and pattern. The drawer shall be fitted with full extension, ball bearing slides and handles of approved make and quality. All drawers to be lockable with single key system. The pedestal shall be provided with required number of castors.
od155054/2024_2025 Computer table (long) with keyboard tray , CPU storage at base in a side and storage drawers at other side. Size 1.2m x 0.6m x 0.75m (h) thickness of sheet shall be 12mm, marine plywood with mica/ vineer lipping, edge band with PVC or teakwood reaper. reputed brand godrej/featherlite/wipro
11.34 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen (blown type) @2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete.
Providing & fixing in position HDF Base wooden flooring with planks of sizes 8 mm thick, 1220 mm length (minimum) and 200 mm wide(minimum), in approved colour, texture and finish. The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4mm thick expanded polyethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm wherever required. The HDF wooden planks shall have minimum density of 900-950 Kg/m3. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.(Make: Earcons, Stark Floor, Scheit)
Providing and fixing Sheer dimout roller blinds with chain drive mechanism 100% polyster fabric with color fastness to light 4-5 grade and patterns having width 7.50cm solid and 5cm sheer with powder coated aluminum pelmet of 75mm under 32mm top and 25mm bottom complete in all respect as per the direction of Engineer in Charge.
Providing and laying 2 mm thick anti static Poly vinyl flooring of laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete.
Supplying and installation of Visitors chair, PU Arm rest, Non revolving, back and seat with ABS, countoured seat mould, (Godrej,Wipro or Bloster make or equivalent)
Storage cabinet for accessories: Storage cabinet for accessories in 19 mm ply board construction having sides, top, front, openable panels laminate finish with internal horizontal shelf 19mm commercial plywood painted (enamel) as per approval. Front panels to have a locking arrangements with one panel having tower bolt on the inner side with handles , magnetic hinges and all complete.
Providing, making and fixing in position partition walls over a wooden frame work of size 50x50mm with hard wood Pinkoda /Violet/ or equivalent frame work at 60cm or nearest as verticals and three numbers of horizontals, spacing as shown in the drawing with 10mm/ 12mm thick marine plywood on two sides of the frame work for a height of 90cm from the bottom or nearest and 5.50mm or nearest thick plain glass/ frosted glass for the remaining height and fixing glass/plywood with teak wood beadings between glass/plywood and wooden frame with suitable junction joints and extra supports if needed for joinery openings.The plywood is fixed to the frame work using steel screws including finishing the joints with joint filler etc.to get smooth and even finished joints including cost and labour charges of all materials and the outer frames fixing to concrete/masonry by chipping and providing tight plugs, making good the damages, including cost of all materials such as all wooden members, plywood on both sides, glass etc. complete, wooden sections confirming to the nearest dimensions etc.for fixed partitions etc complete as in the drawing and as per requirement. The rate inclusive of all material charge, labour, transportation, Scaffolding (If needed) loading/unloading at the work space etc. complete as per the direction of engineer in charge.
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to I.S. 2202 ( part I) On one side only
9.114.1 : Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters, including fixing with necessary screws etc. complete.Triple strip vertical type
9.90.3 : Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete.Size 65 mm
Computer table (long) with keyboard tray , CPU storage at base in a side and storage drawers at other side. Size 0.9m x 0.6m x 0.75m (h) thickness of sheet shall be 12mm, marine plywood with mica/ vineer lipping, edge band with PVC or teakwood reaper. reputed brand godrej/featherlite/wipro
Indirect dimmable light in reporting room
Aadhaar enabled biometric fingerprint reader, Biometric and RFID based door access reader, Magnetic Door lock, Accessories, cables, Electrification, Networking, Installation and Commissioning and customised RF card with lanyard 5 Nos
Antistatic flooring
Smart RACK for Hosting Servers and Switches (NOT TAKEN FOR EVALUATION)
Everrtech Software Pvt. Ltd. (BID ID -2000640)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.15 MB
eTD_PACS.pdf
Tender Documents • 1.20 MB
BOQ_1107301.xls
BOQ • 0.46 MB
Supplierdetails.xls
Other Document • 0.02 MB
Download all tender documents and submit your bid