| 1 | L1₹9.7 LAccepted-AOC PLOT NO 100 VASUDEV NAGAR SONDA 114 PART AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC Lowest L1 |
Tender Value
₹9.7 L
EMD Value
₹19,441
Closing Date
5 Apr 2021, 12:00 pmClosed
Executive Engineer -cum- Chairman GPWSC
Chairman GPWSC Village Issewal, Block Ludhiana-II, District Ludhiana through Executive Engineer, Water Supply and Sanitation Division No.2, Partap Chowk, Metro Road, Ludhiana.
Providing improved access to water through household connections in existing Water Supply Scheme at Village Issewal, Block Ludhiana-II, District Ludhiana. (Under PRWSSIP Sub Component 2a(i)/JJM)
2021_WB_62562_1
No.1256-58 dt.24.03.2021 (Issewal)
Open Tender
Civil Works
Item Rate
60 days
Ludhiana
Please refer Tender documents.
8 documents required · 8 mandatory
₹100
₹19,441
11 May 2021
25 Mar 2021
5 Apr 2021
25 Mar 2021
5 Apr 2021
25 Mar 2021
Amount
Providing Installing testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, and Chemical Dosing Chlorinator, Suitable for delivering 0.5 to 6 Liters of Bleaching Powder solution /Sodium Hypo solution per hour under maximum delivery pressure upto 7 kg.cm2 and suction lift not less than 1.5m per DWSS standard specifications.
Providing & Fixing of Automated Water Controller complete in all respect. (Credit of old water controller also to be given)
Providing Household connection laying, jointing, fixing testing MDPE pipes (as approved by Engineer-in-charge) including cost of excavation refilling , C.I bib clock as IS:210 with stainless steel spindle 20 mm o/d MDPE pipe 4.50 mtr (2.50 mm MDPE & 2.00 mtr G.I, vertical pipe) 3" i/d uPVC clamps, GM ferrule ISI marked connection of 15 mm i/d ferrule medium, specials such as tees, bends, sockets, elbows, nipples (100 mm & 150 mm) union couplings, MDPE pipeline laid in the ground or inside building, cutting, treading, making hole in wall and testing in trenches in ground complete in all respect.
On Existing Pipe Line
On New Pipe Line
Providing, Stringing out PVC pipes ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches To correct alignment and gradients, including excavation cutting, Jointing, testing and back filling complete as per specifications for more than 3 mtr street width.
PVC pipe 63mm o/d (6kg/cm2)
PVC pipe 90mm o/d (6kg/cm2)
PVC pipe 110mm o/d (6kg/cm2)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
Construction of Masonary Sluice Valve Chamber excluding sluice valve cover as per standard design & drawings of public health department.
0.60mtr. x 0.60 mtr.
Dismantling brick or flagged stone flooring without conerete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Brick on edge (63mm)
Brick on edge (110mm)
Dismantling of metallic road with bituminous course 50 to 75mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects as per analysis A – 25
Repair of Pump Chamber
1/17.10 Hollock wood doors shutter windows shutter including hinges, screws, Chocks Cleats, Stops and Cords etc. complete fixed in position (double Leaf) @ paneled glazed or glazed and paneled
(a) Panelled, Glazed or glazed and panelled.
(i) 40 mm thick
(xvii) windows 1x3x0.50x0.60=0.90 sq mtr
2/16.8 Distempering with dry distemper of approved manufacture two coats over one priming coat to give an even shade
Pump Chamber 3.70x4.30
Long wall 4.30x3x2x2 =51.60 Sqm
Short wall 3.70x3x2x2 =44.40 Sqm.
Top 3.70x4.30 = 15.91 Sqm.
Total 111.91 Sqm
Development of water works site
(i) Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-6)
(ii) Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8 & (as per Analysis A-6).
(iii) Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-4 complete in all respects
Provision of Control Panel
Replacement of Machinery 12.50 BHP
Note: The rate of above said Pumping Machinery is to be given with Credit of Old Machinery.
Painting of Sign Board
O & M (Electricity Bill)
Provision for bleaching powder or sodium chlorite for disinfection of water.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .