| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.3 L+₹76,758.15 (2.43%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹33.4 L+₹1.9 L (5.91%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹34.4 L+₹2.9 L (9.06%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹35.5 L+₹3.9 L (12.4%)Rejected-Finance BLOCK NO 11 VIMLNATH APARTMENT PRATAP VILAS ROAD NEAR SATYA SAI SCHOOL JAMNAGAR GUJARAT 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L5 | Rejected-Finance L5 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
9 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aman Bhardwaj
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
PROVN OF CERTAIN MINOR WORKS, MAJOR REVENUE WORKS AND OTHER SANCTIONED WORKS AT AF STATION JAMNAGAR
2022_MES_512135_3
8156/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹58,000
Yes
30 Aug 2022
19 Jul 2022
10 Aug 2022
19 Jul 2022
9 Aug 2022
26 Jul 2022
Amount
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer
Demolition of concrete of any description and in any position not otherwise specifically provided for including removal of debris off the MD land
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / disintegrated rock
All as per item No 5 above but exc 1.50 m and n.exc 3.00 m in depth and getting out in soft / disintegrated rock
Excavating over areas, n exc 1.5 m deep and getting out in soft / loose soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / disintegrated rock
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft / loose soil
Removing excavated material (soils) n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point
Removing excavated material (soils) exc. 50 m but n exc. 100 m and depositing where directed at a level n.exc 1.5 m above the starting point
Removing excavated material (soils) exc. 250 m but n exc. 500 m and depositing where directed at a level n.exc 1.5 m above the starting point
Removing excavated material (rocks) exc. 1.50 km but n exc. 5 km and depositing where directed
M&L for reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses Note:- Reinforcement steel will be measured and paid seperately.
M&L for TMT CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
All as per item No 15 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Use & waste formwork to rough finished surfaces of flat faces of concrete walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc.; vertical or to batter
M&L for cement concrete Type C2 (1:3:6) (40mm graded aggregate) in foundations filling and mass concrete
M&L for cement concrete Type B1 1:2:4 (20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
M&L for polythene film black colour 400 micron (HDPE) laid over base and wall side complete all as directed by Engineer-in-Charge
Demolition of brickwork or stone/ boulder masonry / PCC block masonry, built in cement or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L for pre-cast cement concrete block masonry 1:5:8 (20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel')
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. including removal of debris off the MD land
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4
M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match
M&L for 25 mm thick hardwood 2nd class boarding in floors and skirting planed one side & edges tongued and grooved or rebated,, with butt joints and fixed with nails supplied and fixed
M&L for preparation of new or previously untreated wooden surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer
M&L for preparation of new plastered or unplastered surfaces and applying two coats of oil bound distemper over a coat of primer on walls
M&L for preparation of plastered wall surface including pilaster/cornices etc and applying two coats of acrylic emulsion (exterior weather coat) paint in camouflage pattern of any tint as approved over one coat of primer complete all as specified and directed
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store
M&L for 15mm steel water tubes, 'medium grade' galvanized, with all fitting and fixed complete to walls and ceilings or laid in floors
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store
M&L for 20mm steel water tubes, 'medium grade' galvanized, with all fitting and fixed complete to walls and ceilings or laid in floors
S&F 15 mm size fancy type, chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
M&L for machine pressed precast concrete interlocking paver block of approved shape and size of 80mm thickness, with minimum compressive strength of 40N/sqm (M-40 ), without correction factor for chamfering, made in rubber moulds with 0.50mm thick scratch proof lacquer coating on top surface, with white cement and pigment laid over and including 20mm thick sand screed bed complete
S&F stop valves 15 mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F stop valves 20 mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F 15 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
Demolition of concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of debris off the MD land
M&L for 100 mm thick cement concrete type B- 2, 1:2:4 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc
M&L for sand cushioning 10 mm thick over DLC surfaces spread all as directed by Engineer-in-Charge
M&L for polythene film black colour 150 micron laid over sand cushioning complete all as directed by Engineer-in-Charge
M&L for Cement concrete work in pavements / hard standing of flexural strength 40 Kg/Sqcm in field using 400 Kg of cement/Cum thickness of concrete 25 cm thick or less including steel shuttering to concrete complete all as specified and as directed.
Finishing surfaces of concrete road / pavement by floater, plate vibrator, needle vibrator complete all as specified and directed
Excavating in post holes (or similar holes) each not exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface in any type of soil complete all as specified and as directed
M&L for cement concrete Type B2 (1:2:4) (40mm graded aggregate) in foundations filling and mass concrete
S&F rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for cement concrete Type D2 (1:4:8) (40mm graded aggregate) in foundations filling and mass concrete
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
S&F flush shutters 30 mm thick , solid core construction, with block board core and plywood face panels, commercial type on both sides
S&F 0.9 mm decorative laminates type I, or surface finish, colour and pattern as approved
M&L for rendering 5 mm thick on concrete ceiling in cement mortar 1:3, finished even and smooth without using extra cement
M&L for 25 mm thick cement concrete type B- 1, 1:2:4 (20mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc
S&F 15mm size angular cock, cast copper alloy, CP fancy type with capstan head, screwed down, screwed both end for iron pipes complete
S&F PVC (SWR) pipes 110 mm bore, single socketed in any length with rubber ring joints fixed to walls
S&F PVC (SWR) pipes 110 mm bore, double socketed in any length with rubber ring joints fixed to walls
S&F PVC (SWR) pipes 110 mm bore, double socketed in any length with rubber ring joints laid in trenches or in floors
S&F PVC (SWR) pipes 75 mm bore, double socketed in any length with rubber ring joints fixed to walls
S&F PVC (SWR) pipes 75 mm bore, double socketed in any length with rubber ring joints laid in trenches or in floors
S&F 10 litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket and connections to pipes and fixing of chain and pull, or lever.
S&F cold rolled mild steel butt hinges medium grade 125 mm long
S&F aluminium handles, 150 mm size, cast type, anodised
S&F vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts & P or S trap) and finishing with white cement
S&F aluminium (powder coated with approved colour) ventilator, partially glazed and partially louvers, outer frame & mullion fabricated with alumimium section of size 82.50mm x 38.00mmx1.5mm thick (Cat No 20036), half portion glazed with 4mm thick frosted glass including rubber beading & glazing clip, half portion louvers of 80mm wide & 4mm thick frosted glass including alumimium louver patti including SS wire gauge of fixing of 0.36mm dia and 1.40 width of aperture with 25x3mm thick aluminium strip with screw to upper half portion of ventilator all fitting & fixture and fixed in position. Note : Section Nos given above are of make Jindal, contractor may use similar setion of other make mention in Appx B
M&L for Non - skid joint free coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including screed bed or bedding layer of cement mortar 1:6, 15 mm thick
M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, over and including 10mm thick backing coat in cement mortar 1:4
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like set and jointed in cement paste including backing coat in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
S&F plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device
S&F brass chromium plated shower rose 75 mm size with arm 15 mm inlet
S & F PVC (SWR) bends 110mm bore any radius
S & F PVC (SWR) bends 75mm bore any radius with access door
M & L for PVC (SWR) floor trap 75mm dia , plain with grating including jointing with solvent cement
M & L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
S & F PVC (SWR) vent cowl 110mm bore
S&F for PVC connection 15 mm size with brass nuts of length 450mm
S&F white vitreous china counter top wash hand basin, oval shape of size-450x580x165mm fixed on granite counter by making suitable size hole, new brackets, 32mm dia brass chromium plated waste coupling,PVC waste pipe complete all as specified
S&F gun-metal, globe or gate valves 20 mm bore dia of pipe, with iron wheel head, screwed both ends for iron pipe and fixed
S&F cast iron floor trap 100 mm dia of outlet, with grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4)
M&L for cement concrete 1:4:8 type D2 (using 40mm graded aggregate) bed to drain pipes including packing under and haunching against the sides of pipes 150mm dia bore after they are laid and tested
M&L for Salt-glazed stoneware drain pipes grade 'A' of internal diameter 150 mm laid in trenches and jointed as specified
Use & waste of Formwork to rough finished flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Use & waste of formwork to rough finished flat sides of concrete pillars, posts, struts, piers, columns and stanchions, Square, rectangular or polygonal
Use & waste of formwork to rough finished flat sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Use & waste of formwork to rough finished flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
M&L for reinforced cement concrete M-30 (design mix) using 20 mm graded aggregates in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L for reinforced cement concrete M-30 (design mix) using 20 mm graded aggregates in Columns, pillars, piers, posts and struts
M&L for reinforced cement concrete M-30 (design mix) using 20 mm graded aggregates in Beams, cantilevers, bressummers, lintels over 1.5m span
M&L for reinforced cement concrete M-30 (design mix) using 20 mm graded aggregates in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash
M&L for 75 mm thick cement concrete type C- 2, 1:3:6 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc
S&F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding
M&L for screed bed or bedding layer of mortar 10 mm thick in cement mortar 1:4 including mixing only liquid water proofing compound as per manufacturers' instructions and finishing the surface fair and even. Note:- WPC will be measured & Paid separately
Supply only liquid water proofing compound
Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg / Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane (mineral finish) reinforced non-woven polyester, weight not less than 3.0 Kg / Sqm and sealing all the over laps 150 mm in length side and 100 mm in width side of membranes laid with torch application complete all as specified and as directed.
Supply and fix 1000 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 25 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe complete.
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms)
S&F Soap dish, vitreous China white, approximate size 160x 160x90mm
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 including mixing only water proofing compound as per manufacturer's instruction. Note:- Water proofing compound will be measured and paid seperately
M&L for 75 mm thick cement concrete type D- 2, 1:4:8 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc
M&L for Hardcore of Broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L for screed bed or bedding layer of mortar CM (1:4) 20 mm thick for laying floor finishes
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3
S & F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern
S&F 110mm PVC (SWR) WC connector bent type
S&F vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)
S & F 32 mm Bottle trap of PTMT having minimum water seal of 25mm . (Minimum weight 260 gms)
S & F 32 mm waste coupling of PTMT (half or full threaded) (Minimum weight 45gms)
S&F 32 mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe
S&F Vitreous China wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets
S&F Rubber or vulcanite plugs (waste) with rings and fitting and fixing
M&L for precast cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:6 Note:- Reinforcement steel will be measured and paid seperately.
M&L for TMT bars 6 to 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Supply & fix Anaerobic Package Type modular Septic tank of capacity 1200 litre (25 Users), maintenance free, placed over 150 mm thick PCC base of Mix 1:3:6 type C2 (using 40mm graded stone aggregate), connecting with inlet & outlet pipe including Excavation & earthwork, in any type of soil, backfilling with sand complete, all as per manufacture's instruction. Make:- Sintex Model No PWTS-AM 120-01 or equivalent make as approved by the GE.
M & L for Soakage well of size 2.4 m dia x 3.0 m depth excavation in any type of soil with brick work in CM (1:4) and RCC Cover Slab and filling with brick bats Complete as per TD drawing No CEAA/TD/80
M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
M&L for providing dry river sand as in sand cushioning to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. (Note: for measurement purpose any punned thickness of sand will be considered.)
Supply & laying factory made unreinforced precast concrete cable cover conforming to IS - 5820 - 1970, Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed by Engr-in-Charge.
Laying only LT / CCR cable of any size and make all as directed by Engineer-in-Charge. Note:- i) Re-routing of CCR cable will be done under the guidance of concerned representative of CCR ii) Accessories required for rectification of CCR cable / new cable will be directed by CCR department
M&L for boring under roads / pavement / hard standing without disturbing the top surface by trench less technology using ultrasound technique including inserting HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost.
Supply and laying GI tubing 40 mm dia bore light grade laid under the roads / drain / culverts/ pole / wall with necessary fittings & fixture etc all as specified and directed.
S&F PVC flat twin core cable with aluminium conductor of size 4 mm
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 25 mm
M&L for 25mm steel water tubes, 'medium grade' galvanized, with all fitting laid in trenches
Material & Labour for concealed point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FRLSH cable 1100 volts grade ISI marked drawn and including PVC conduit 20mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FRLSH cable as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with bakelite cover complete. ( Note - Cost for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 is deemed to be included in quoted rates)
All as per item No 138 above but for one 3 pin socket outlet 5 Amps on independent board controlled by one-way switch.
All as per item No 138 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed FRLSH, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed FRLSH, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
S&F modular type white switch 6 Amps one way switch, 230 volts in one module
S&F modular type white switch 16 Amps one way switch, 230 volts in one module
S&F modular type white shuttered socket 3 pin 6 Amps 230 volts in 2 modules
S&F modular type white shuttered socket 2/3 pin combined 16 Amps 230 volts in 2 modules
S & F modular white cover plate with frame, 2 module
S & F modular white cover plate with frame, 3 module
S & F modular metal flush box, 1/2 module
S & F modular metal flush box, 3 module
M&L for Ceiling rose, 3 phase / PVC / polycarbonate, isolated body
Material & Labour for sub main wiring with 4 run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed FRLSH drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, FRLSH as earth wire, fixed on wall / ceiling complete. Note: 4 Runs of main cable and one run earth wire with mild steel ERW conduit will be measured as one RM for payment.
S&F energy efficient 18 / 20 W LED Energy saving tube light fitting with built in LED & integral LED driver 18 watt (1800 lumen), aluminium extruded channel housing & diffuser with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engineer-in-charge
S & F sheet metal enclosure MCB DB SPN 4 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and directed by Engineer-in-charge
S & F sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and directed by Engineer-in-charge
Supply and fixing single pole 6 to 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) complete with connection testing and commissioning.
Supply and fixing single pole & neutral 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) complete with connection testing and commissioning.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m
S&F wall fan of 600mm sweep, 240V, 50 Hz, metallic body, heavy duty, single phase complete all as specified and as directed by Engr-in-charge
Supply & Fixing energy efficient Led tube light fitting with built in LED & integral LED driver 10 watt, channel housing & diffuser of length 600 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg-in-charge
S&F Building security light fitting LED 30 W, High efficiency IP 65 protection, consisting of electronics driver circuit high quality transmitted lens, powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on bracket & connecting Note:- Bracket will be measured and paid seperately
S&F LED security light bracket fabricated from 25mm bore galvanised iron tubing light grade 1.2 metre long bent to shape fixed on building including mild steel flat iron clamps, nuts, bolts etc complete all as specified and directed
Sagathiya Builders
Jagdamba Engineering
Sukhi Electricals
Nirmal Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .