The Executive Engineer (O&M), DGVCL Piplod Division Office, Surat.
Erection of HT, LT line & T/C Replacement of O/H line conductor with abc, dismantling of pole & transformer center, Maintenance of old HT,LT line, Transformer centre, Erection of Overhead XLPE, Transformer earthing and other miscellaneous work under various schemes at Piplod sub division & any other sub division under Piplod Division.
302094
DGVCLDPPL/0651/04/2026 Approved Date: 04-05-2026
Open
Electrical
Works
Surat
1 document required · 1 mandatory
₹1,180
SURAT@DGVCL
₹27,000
6 May 2026
6 May 2026
6 May 2026
20 May 2026
6 May 2026
Name of Work :-Tender for Erection of HT, LT line & T/C Replacement of O/H line conductor with abc, dismantling of pole & transformer center, Maintenance of old HT,LT line,
Transformer centre, Erection of Overhead XLPE, Transformer earthing and other miscellaneous work under various schemes at Piplod sub division & any other sub division under Piplod
Sr. No. Item Code Item Unit FY 2024-25
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS, CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF FABRICATED MATERIALS
AND NUMBERING COMPLETE WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND REFILLING OF EARTH,
FIXING OFCROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING DEVICES, INSULATORS ETC.
2 9926000002 COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH No.
COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLES OF 9 TO 11 METERS INCLUDING EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING
OFCROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF
STEEL POLE, FABRICATED MATERIALS USED ON THE POLEAND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY CROSSING ON BG/MG/NG LINE FOR
0.400/11/22KV OVERHEAD LINES I.E INCLUDING EXCAVATION OF PIT & REFILLING OF EARTH, FIXING
CROSS ARMS, TOP FITTING CLAMPS,ANTI-CLIMBING DEVICES DANGER BOARD, INSULATORS ETC.
COMPLETE AND PAINTING OF STEEL POLES, FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS 200 KG PSC POLES INCLUDING EXCAVATION
OF PITS & REFILLING OF EARTHING, FIXING OF CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-
5 9926000005 CLIMBING DEVICES DANGER BOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF FABRICATED No.
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO 11 METERS.STEEL POLE INCLUDING EXCAVATION OF PITS &
REFILLING OFEARTH, FIXING OF CHANNELS, SUPPORTING ANGLES, CLAMPS,ANTI-CLIMBING DEVICES DANGER BOARDS,
INSULATORS ETC.COMPLETE & PAINTING OF POLES,FABRICATED MATERIALSUSED ON THE POLES AND NUMBERING WITH COST
OF PAINTSAS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH, HG FUSES OF 8 MTRS
KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH,FIXING OF CHANNELS
SUPPORTING ANGLES, CLAMPS, ANTI-CLIMBING DEVICES, DANGER BOARDS, INSULATORS,DOFUSES
ETC. COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING
WITH COSTOF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDINGOF ERECTION OF GUY SET
AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH,HG FUSES, 9 TO 11 METERS
STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH, FIXING OFCHANNEL, SUPPORTING ANGLES, CLAMPS,
8 9926000008 ANTI-CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC. COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS No.
USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SET AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OFAB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF 8 METER,200KG PSC POLE
METERS POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO SITE, FIXING OF CHANNELS, SUPPORTING ANGLES,BRACINGS
CROSS ARMS CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USEDON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH,HG FUSES
TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX 9 TO 11 METERS STEEL POLES INCLUDING
10 9926000010 EXCAVATION OF PITS & REFILLING OF EARTH CARTING OF TRANSFORMERS FROM STORE TO SITE, FIXINGOF CHANNELS No.
SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTICLIMBING DEVICES, DANGER BOARDS,CONDUCTOR AND CABLE
WIRING ETC. COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND NUMBERING AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTIONS OF GUY SETS AND EARTHING.
ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH AS PER STANDARD
11 9926000011 SPECIFICATION WITH STAY CLAMPS, STAY WIRE, ANCHOR ROD, TURN BUCKLE, EYEBOLT, GUY No.
INSULATOR, CEMENT CONCRETE BLOCK ETC. BUT EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC. INCLUDING COST OF CEMENT SAND METAL (1:2:4) AND WATER
ETC. AS PER STANDARD SPECIFICATION.(cement Should be 53 grade) used for Concreting.
ERECTION OF COIL TYPE EARTHING INCLUDING COST OF COAL,SALT ETC. BUT WITHOUT COST OF GI
WIRE AS PER STANDARD SPECIFICATION(20kg solt+20kg coal)
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING INCLUDINGCOST OF COAL SALT ETC. BUT WITHOUT
COST OF PIPE/GIPLATE GI WIRE AS PER STANDARD SPECIFICATION.(20kg solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH CLAMPS, BRASS NIPPLE, BRASS HOLDER
15 9926000015 TECK WOOD BUSH,REFLECTORS FUSE, WIRING ETC. AS PER STANDARD SPECIFICATION BUT No.
EXCLUDING COST OF MATERIALS.
STRINGING OF(30mm2)ACSR/34MM@,55MM2 AAA CONDUCTOR for ALL TYPE OF CONDUCTOR
16 9926000016 (EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING FIXING OF INSULATORS, BINDING
17 9926000017 STRINGING OF GI WIRE 8 SWG INCLUDING BINDING JUMPERING ETC. DO
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC 2.5/4MM2 TWIN CORE CABLE FROM
18 9926000018 TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER WITH METER EARTHING No.
COMPLETE WORK AS PER STANDARD SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION WITH PVC 4MM2/10MM2 FOUR CORE CABLE
19 9926000019 FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER WITH METER EARTHING No.
COMPLETE WORK AS PER STANDARD SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
Sr. No. Item Code Item Unit FY 2024-25
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK AREA FOR ERECTION OF POLE/ GUY ETC.
AS PER STANDARD SPECIFICATION OVER & ABOVE NORMAL COST COVERED AGAINST EXCAVATION
OF PIT UNDER NORMAL SOIL FOR ERECTION OF POLE,GUY, DOUBLE POLE STRUCTURE EARTHING
WITH THE APPROVAL OF SUPDT.ENGINEER.
21 9926000021 PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL CROSSING. MTR
22 9926000022 PROVIDING GUARDING OF LT LINES ON ROAD/RAIL CROSSING. MTR
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING,HT LINE CROSSING AND
TELEPHONE LINE CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES WITH , HG FUSES,TRANSFORMERS, LIGHTENING
ARRESTOR, DISTRIBUTION BOX. ON 8 METERS 200 KGAND PSC POLE INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH, CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING OF
26 9926000026 CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES No.
DANGER BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLE AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRUCTURES WITH MOUNTING OFAB SWITCH , HG
FUSES,TRANSFORMERS, LIGHTENINGARRESTOR, DISTRIBUTION BOX. ON 9 to 11 METERS RSJ POLE
27 9926000027 INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH, CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING OF No.
CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR AND
CABLE WIRING ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLE AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS AND EARTHING.
ERECTION OF PSC POLES OF 10 *270 KG INCLUDING EXCAVATION OF PIT AND REFILLING OF EARTH,
FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING DEVICES, INSULATORS ETC.
28 9926000028 COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH No.
COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF DOUBLE POLE STRUCTURE OF 10 METERS 270 KG PSC POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTHING, FIXING OF CHANNELS, SUPPORTING
ANGLES,CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARDS,INSULATORS ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2 AAAC CONDUCTOR FOR 11/22KV & LT LINES INCLUDING FIXING ONE COND
OFINSULATORS, BINDING JUMPERING ETC. PER KM
STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT LINES INCLUDING FIXING OF INSULATORS, ONE COND
BINDING JUMPERING ETC. PER KM
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OF AB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF 10 METERS 270 KGAND PSC
POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS
CLAMPS, ANTI-CLIMBING DEVICES,DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING
WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS
DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE & STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE & STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITH TRANSFORMER) WITH
35 9926000035 CREDITING OF FABRICATION & TRANSFORMER AT STORE & STACKING OF POLE SAFELY ON ROAD No.
SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITHOUT TRANSFORMER) WITH
36 9926000036 CREDITING OF FABRICATION AT STORE & STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING No.
TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM INCLUDING FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE INSULATOR
37 9926000037 ETC. FOR FIXING OF MESSENGER WIRE AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH KM
CABLE BY INSULATED PIERCEING CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE
AS REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT
38 9926000038 SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH CABLE BY INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM INCLUDING FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, BINDING TO PIN
INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS REQUIRED & DIRECTED BY ENGINEER IN
Sr. No. Item Code Item Unit FY 2024-25
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM INCLUDING FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, BINDING TO PIN
INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS REQUIRED AND DIRECTED BY ENGINEER
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT
41 9926000041 SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND TO PROVIDE SERVICE KM
CONNECTION ON AERIAL BUNCH CABLE BY INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
42 9926000042 DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING THE OLD MATERIAL TO STORE No.
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC POLE(WITHOUT TRANSFORMER)
43 9926000043 WITH CREDITING OF FABRICATION AT STORE AND STACKING OF POLE SAFELY ON ROAD SIDE OR No.
CREDITING TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC POLE(WITH TRANSFORMER) WITH
44 9926000044 CREDITING OF FABRICATION AT STORE AND STACKING OF POLE SAFELY ON ROAD SIDE OR No.
CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND CREDITING FITTING OF ALL ACESSARIES
AND FABRICATION TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES AND FABRICATION TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT LINES ONE COND
INCLUDING FIXING OF INSULATORS, BINDING JUMPERING ETC. PER KM
51 9926000051 RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES INCLUDING , BINDING JUMPERING ETC.
LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR METER. (METER WILL BE PROVIDED BY
LABOUR CHARGE FOR THE REPLACEMENT OF DTR METER AND OLD METER SHOULD BE CREDITED
TO SDN STORE. (METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR METER CONNECTION. (CT COIL WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR DTR METER CONNECTION AND OLD CT
SHOULD BE CREDITED TO SDN STORE. (CT COIL WILL BE PROVIDED BY DGVCL)
56 9926000056 LABOUR CHARGE FOR FIXING OF MMB FOR DTR METER (MMB WILL BE PROVIDED BY DGVCL) No.
57 9926000057 LABOUR CHARGE FOR REPLACEMENT OF DTR METER BOX. (METER WILL BE PROVIDED BY DGVCL) No.
PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE COPPER CABLE 3.5 METER (CABLE TO BE
PROVIDED BY AGENCY)
LABOUR CHARGE FOR PROVIDING/RECONNECTION OF TERMINAL CONNECTION WITH PROPER SIZE
59 9926000059 TERMINATI
OF LUGS. (LUGS COST IS BORNE BY AGENCY)
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH DETAIL SURVEY OF DEFECT IF ANY.
A DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN PRO-FORMA REPORT SHOULD BE
SUBMITTED TO SDN OFFICE.(* ONLY IF ALL PARAMETER OF VOLTAGE, CURRENT & LOAD AS SHOWN
IN PER-FORMA IS FILLED) AS PER THE INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH DETAIL SURVEY OF DEFECT IF ANY.
A DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN PRO-FORMA REPORT SHOULD BE
SUBMITTED TO SDN OFFICE. (DULY FILL PER-FORMA IN FAULT CONDITION IN WHICH READING
PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING METER BOX, PROVIDING & FIXING OF 1.5SQ MM SINGLE
62 9926000062 STRAND 10 CORE ARMOURED COPPER CABLE (3.5METER), TERMINATION IN METER & COIL No.
ETC.(METER, METER BOX, C.T./P.T. COIL WILL BE PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING METER BOX, TERMINATION IN METER & COIL ETC.
63 9926000063 (WITHOUT 10CORE COPPER CABLE) (METER, METER BOX, C.T./P.T. COIL WILL BE PROVIDED BY No.
Binding of messanger Conductorat with a distance not more than 0.75 mtr with 6 turns minimum on XLPE Cable
with single strand binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution Transformers HT Terminal protector (UV Resistance) with using
95/120/150 sq.mm long barrel aluminum lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV Distribution Transformer with replacement of bare conductor by
66 9926000087 HT ABC conductor (DO bottom side to transformer) after removal of semi conductor by HT ABC (6 inch both PER SET
side). HT ABC to be supplied by DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic) Type,
67 9926000088 Earth Electrodes for HT Feeder Pole Having 2000 mm Electrode Length as per the Tender Specifications and NO
Drawing. (All Materials Will Be Supplied By Agency)
Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic) Type,
68 9926000089 Earth Electrodes for HT Feeder Pole Having 3000 mm Electrode Length as per the Tender Specifications And NO
Drawing. (All Materials Will Be Supplied By Agency)
Sr. No. Item Code Item Unit FY 2024-25
Supply and Installation of 25 X 3 mm GI Strip having hot dip- galvanized-zinc coating of 80-100 microns without
any joints or welding. Both the end of the GI strip should be connected with GI nut bolts and required fabrication
work for giving separate earthing connections to
(1) Neutral of the transformer
(2) MS structures of the transformer center (Approximately 25 meter GI strip per transformer centre
- as per requirement and instruction of Engineer in- charge) (All Materials will be supplied by Agency)
Supply and Installation of uPVC standard make Pipe of 1.25" diameter for covering GI strip with UV protected
70 9926000092 Cable Ties of 550 X 7.6 mm size to bind with pole face(Approximately 25 meter uPVC pipe for GI strip covering Meter
per transformer centre -as per requirement and instruction of Engineer in-charge.
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Drop out Fuse and Drop out fuse to Transformer
H.T. including Busbar (12 mm sleeve) as per technical specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Drop out Fuse and Drop out fuse to Transformer
H.T. without Busbar (12 mm sleeve) as per technical specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleev for Bus bar to Drop out Fuse and Drop out fuse to Transformer
H.T.including Busba r(15mmsleev) as per technical specification. (All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to Drop out Fuse and Drop out fuse to Transformer
H.T. without Busbar(15 mm sleeve) as per technical specification. (All Materials will be supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-flammable) material with Weather resistant, Non-conductive bird
75 9926000095 guard OD=300 MM, ID=33 MM, Width =1.25 MM, one NO
side cut from ID to OD. (All Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e. Re-useable boot (LT Side 1.1 Kv) including LT (1.1 kV)
76 9926000096 insulating taps. All live part at LT side shall be covered with fixing NO
of LT insulating taps.
77 Nylon Net around Transformer Center
77.1 9926000097 Nylon Net (12 * 15 ft) Per Net
77.2 9926000098 Nylon Dori Per TC
77.3 9926000099 Labour charge for fitting Nylon Net (All fabricated material for fitting nylon net shall be provided by DGVCL) Per TC
78 9924000001 Cutting of Tree branches surounding HT/LT line Per Tree
Replacement of old jumpers & providing new double jumpers with 8" binding [D Type] & capsuling with PVC
80 9924000005 Support pole for Stay PSC/STP/RSJ No.
81 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
82 9924000007 Pin binding of conductor 11/22kv Pin insulator per pole in costle area with cleaning . No.
83 9924000008 Pin binding of conductor LT shakel insulator No.
84 9924000009 Replacement of one/both disc.insulator at strain pole No.
85 9924000010 Replacement of LT shackle insulator at cut point No.
86 9924000011 Refixing of V cross Arm No.
87 9924000012 Replacement of V cross Arm (With Transportation & Painting) No.
88 9924000013 Refixing of Top fitting in proper position No.
89 9924000014 Replacement of Top fitting No.
90 9924000015 Replacement of LT cross Arm No.
91 9924000016 Providing DO fuse on DP with carting & jumpuring(ONE DO FUSE) No.
Numburing of pole with paint by preparing back ground of one colour and have lettering(height 3" * width 0.5")
93 9924000018 Fixing of MMB(1PH.) at consumer end No.
94 9924000019 Fixing of MMB(3PH.) at consumer end No.
95 9924000020 Replacement of (1ph.) meter for Urban area No.
96 9924000021 Replacement of (1ph.) meter for Rural area No.
97 9924000022 painting consumer no. on MMB (Urban) (with letter size height 40mm* width 8mm) No.
98 9924000023 painting consumer no. on MMB (Rural) (with letter size height 40mm* width 8mm) No.
99 9924000024 Replacement of deteriorated Single phase Service line No.
100 9924000025 Fixing of new dist. Box with complete wiring including clamps,nut bolts etc. No.
101 9924000026 Reparing of guarding involving reshaping of bearer wire cross lacing binding etc. R Mtr.
102 9924000027 Painting of steel fabricated material of RSJ DO DP structure with paint No.
103 9924000028 Painting of steel fabricated material of RSJ pole mounted transformer double pole structure with paint No.
104 9924000029 Painting of steel fabricated material of RSJ single pole with paint No.
105 9924000030 painting of steel fabricated material of PSC Single pole (HT line) with paint No.
106 9924000031 painting of steel fabricated material of PSC DO DP double pole with paint No.
107 9924000032 painting of steel fabricated material of PSC double pole at pole mounted transformer with paint No.
108 9924000033 Providing line seperater single phase No.
109 9924000034 Providing line seperater three phase No.
110 9924000035 Replacement / Providing of stay insulator along with adjustment of tension in stay wire No.
111 9924000036 Replacement of deteriorated /providing LT dist. Box with new up to 100KVA capacity & crediting it to store. No.
112 9924000037 Replacement of deteriorated /providing LT dist. Box with new above 100KVA capacity & crediting it to store. No.
113 9924000038 Adjustment of tension in stay wire No.
114 9924000039 Refitting of LA No.
115 9924000040 Converting pin point to Shackle point including dismentaling & restringing etc. location
116 9924000041 replacement of 11KV Pin insulator with providing new double pin binding No.
117 9924000042 replacement of 22KV Pin insulator by new 11kv pin insulator with spares & providing new double pin binding No.
118 9924000043 Providing 11kv double disc insulators with binding & restringing No.
119 9924000045 Replacement of existing 11kv conductor (all size) with new double pin binding Cond/KM
120 9924000046 Plumbing of PSC Pole with straightening at pin point No.
Sr. No. Item Code Item Unit FY 2024-25
121 9924000047 Plumbing of PSC Pole with straightening at tension point No.
122 9924000048 Plumbing of tilted DP structure (PSC/RSJ/STP) with refilling of stone Murrum etc. No.
123 9924000049 Providing new 11kv AB /GO switch with fabrication and insulated colour code jumper, binding, lugs etc Set
124 9924000051 Replacement of old 11kv AB /GO switch with providing new insulated jumper, binding, lugs etc Set
125 9924000052 Providing cage type loop guard in verticle LT line with using PVC reel insulators etc per pole
126 9924000053 Labour charges for replacement /providing of MMB & service with all accessories for three phase connection No.
127 9924000054 Labour charges for replacement /providing of MMB & service with all accessories for single phase connection No.
Dismentalling of existing Dist.X'mer center(RSJ /STP POLE) 25/63/100/200 KVA with all fabrication & creditig the
old material to store
Disconnection from LT pole 1 phase
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
Disconnection from LT pole 3 phase
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
133 9924000060 Dismentaling & removing of service line from pole & crediting to S/dn (1 ph.) No.
134 9924000061 Dismentaling & removing of service line from pole & crediting to S/dn (3 ph.) No.
135 9924000062 Reconnection of service line complete with PVC cable (1 Ph) No.
136 9924000063 Reconnection of service line complete with PVC cable (3 Ph) No.
Providing spiral type earthing by G.I. NO 8(weight 2kg -5mtr in length) with salt and coal 10kg each, including pvc
137 9924000064 rigid pipe 20mm dia( 1.5mtr length) to pass exposed part of G.I. wire at consumer end with all materials, earth No.
resistance should be less than 2 ohms
Providing and fixing of signle core 1.5 sq mm single strand copper insulated cable with cable nail clip for spiral
type earthing at consumer end. The end of G.I. no 8 is to be connected by connector with copper cable of which
138 9924000070 per meter
other end shall be connected to the earth terminal of meter box. This item shall be used in location where there is
more distance between earth terminal and earthing terminal of meter. (All materials supplied by contractor)
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing of messenger wire and
139 9924000065 inclusive of dismantling charge of existing bare conductor and crediting in to store & dismentaling of service line KM
from LT bare conductor and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer in Charge.
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM including fitting of all acessaries i.e. special
design suspension / tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing of messenger wire and
140 9924000066 inclusive of dismantling charge of existing bare conductor and crediting in to store & dismentaling of service line KM
from LT bare conductor and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding to pin insulator,preparing shackle point,jumpers etc. and
inclusive of dismantling charge of existing bare conductor and crediting in to store complete as required &
directed by Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding to pin insulator,preparing shackle point,jumpers etc. and
inclusive of dismantling charge of existing bare conductor and crediting in to store complete as required &
directed by Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM including fitting of all acessaries i.e. special
design suspension / tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing of messenger wire and
143 9924000069 inclusive of dismantling charge of existing bare conductor and crediting in to store & dismentaling of service line KM
from LT bare conductor and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer in Charge.
Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ pole with cable connection arrangement along with
144 9925000010 fitting of necessary fabrication for 11KV cable including excavation of pit & refilling of earth as per instruction of No.
EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr RSJ pole with cable connection arrangement along with fitting
145 9925000011 ofnecessary fabrication for 11KV/22 KV cable including excavation of pit & refilling of earth as per instruction of No.
EIC. (Exclusive of concreting & muffing of poles)
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole with cable connection arrangement along with
146 9925000012 fitting of necessary fabrication for 11KV cable including excavation of pit & refilling of earth as per instruction of No.
EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 8.0 Mtr PSC pole with cable connection arrangement along with fitting
147 9925000013 ofnecessary fabrication for 11KV/22 KV cable including excavation of pit & refilling of earth as per instruction of No.
EIC. (Exclusive of concreting & muffing of poles)
on DP Structure with fixing
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to 300 mm
148 9925000014 of 02 Nos polymer cleats on top and middle part.Polymer cleats, nut bolts etc. fixing Per Job
material to be provided by contractor.
Providing & fixing of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm thickness H.D.P.E.
pipe confirms to IS 4984 and BIS certification on the erected DP structure for the mechanical
protection of cable by inserting the cable inside HDPE pipe. The HDPE pipe shall be erected in such
a way that 300mm shall be below the ground level and the rest 2700 mm shall be supported on
the DP Structure with 01 No Polymer cleat.All materials including polymer cleat and Nut bolt to be
provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B GI pipe with pit to be filled with salt
& coke and construction of chamber as per DGVCL Drg. No. dg /100 for DP and cable. The earthing
pit should be joined with cable by G.I. strip of size 1” width & 2 mm thick. All material GI pipe, Coke,
Salt etc will be supplied by bidder.
Sr. No. Item Code Item Unit FY 2024-25
Supply & fixing of heat shrink type end terminations (outdoor) for upto 11kV 3C x 185 mm2 size XLPE No.
cable as per DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations (outdoor) for upto 22 kV 3C x 185 mm2 size No.
XLPE cable as per DGVCL technical specification)
Supply & fixing of heat shrink type end terminations (indoor) for upto 11kV 3C x 185 mm2 size XLPE No.
cable as per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations (indoor) for upto 22 kV 3C x 185 mm2 size No.
XLPE cable as per DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint for upto 11kV 3C x 185 mm2 size XLPE No.
cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through joint type for upto 22kV 3C x 185 mm2 size XLPE No.
cable as per DGVCL technical specification
Labour charge for excavation of 2100mm long x 1200mm wide x 1200 mm deep joint pits for
installation of 11kV / 22kV Straight through joints as per instruction of engineer-in-charge &
covering the cable with 150 mm dia (Outer), thickness 25 mm, 1.0 meter long RCC half round muffs
& refilling same as per instruction of EIC .
Providing and fixing of insulating bus bar, made from 11KV/22KV XLPE cable after removal of semi
conducting layer and applying of PVC heat shrinkable anti-tracking core insulating tubing (1.1KV),
on both end terminal using Aluminium long barrel heavy duty up to 300 sq mm lugs, Aluminium bus
158 9925000024 connector. Taping with PG- clamp for bus conductor as per drawing and as per instruction of EIC. No.
The Alluminium lugs and PG clamp shall be covered with 11KV/22KV HT insulating
tapes.(11KV/22KV XLPE cable will be in scope of DGVCL while all other materials will be in bidder's
Testing of cable at various points and commissioning the feeder as per instruction of engineer-in-
charge.Test result shall be submitted by contractor with bill.
Preparation and submission of 6 (six) copies, of complete layout drawings with GIS mapping as per
actual cable routing showing road crossing, HDPE pipe sleeving, jointing locations, markers etc.
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W) from 3 mm aluminium sheet
along with 1.0 mm dia aluminium binding wire for fixing of aluminium tag near end termination joint at
DP structure for identifyng the cable. The details of feeder i.e. 11 / 22 KV with feeder name shound
be punched on the tag by letter punch of size 16 mm as per instruction of In-charge Engineer.
Modifications e.g.Providing and fixing of Terminal protectors i.e. Re-use able boot (HT Side 11/22KV, LT Side
1.1KV) including 11/22 KV insulating taps and L.T.(1.1 KV) insulating taps ,Busbar, Tapping from Bus Bar
(11/22 KV XLPE cable) through P.G. Clamp for H.T. Jumper to D.O. Fuse to bushings of Transformer Center,
providing & Fixing of jumper and providing & fixing of Heat Shrinkable Anti Tracking Core Insulating Tubing
162 9925000046 (Insulation Level 11/22 KV) in H.T. jumper , Clamping arrangement of cable support frame on both side of No.
existing Over Head type Distribution Transformer to utilize in Under Ground cable network as per drawing & as
per instruction of Engineer incharge. All live parts i.e. PG-Clamp, connections of D.O.fuses, HT bushings etc .
shall be covered with fixinng of 11/22 KV HT insulating tapes. ( 11/22 KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope ) .
163 9925000047 Laying of any size of 11/ 22 KV XLPE /PILC Cable in redaymade trench or in open space
164 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
165 9925000064 Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC half round pipe No.
166 Dismental OF 100MM2 AAAC CONDUCTOR KM
167 Supply and fixing of Suspenssion clamp to Hold the cable (J-Hook) NO
Model:ETP/HDR/17/2
168.1 Terminal Size: 25mmX 6mm Length: 2 Mtr NO
With clamp & 2 no’sof M10 size SS nut & terminal to T/C neutral separately
using Bolts with connection of earthling 25X 3mm Hot Dip GI strip(per
Transformer/ Earthling 04 Mtr GI patti)Installation of Earthling PIT ,work
includes supply and
labour for connectionall respect.
Ground Conductivity
Improve Material,
168.2 Hydrolyte Net NO
Providing and fixing Green HDPE pipe ,size 160 mm Dia X 5 mm thickness X 7 feet height . & GI clamp size
169 X 3 mm (1 Round clamp & 2 Nos C -type Clamp with GI bolts – nuts (10 nos.) Danger sign sticker with toll free NO
number of DGVCL embossed
Sr. No. Item Code Item Unit FY 2024-25
1.DGVCL will provide key material like M.S. materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated
materials etc. to the contractor.
2.All fabricated items shall be fabricated as per DGVCL approved drawing and by welding rods confirming to the
relevent ISI specification and as directed by Engineer in charge.
3.Necessary electricity connection for fabrication items shall be provided by DGVCL on payment of required
charge for connection & electricity bill of the same shall be paid by the agency.
4.All the rates are inclusive of PF & Exclusive of GST applicable time to time.
5.All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles & steel fabricated
materials of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ poles & steel
fabricated materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver paint) is to be
properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC poles.
6.BidderwillhavetoprovideastickeronHDPEPIPEatcablerisinglocationdescribingrouteofcableasperinstructionofEngi
IN WORDS ( Twenty Seven lakhs rupees)
Piplod Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
OH TC ERECTION PIPLOD SDN.pdf
tender description OH.pdf
SCHEDULE B - Copy.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .