Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹29.9 L+₹4.0 L (15.3%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹30.0 L+₹4.1 L (15.9%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹30.6 L+₹4.7 L (18.2%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
15 Apr 2021, 6:00 pmClosed
Garrison Engineer Utility-II
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
MANNING AND OPERATION TO COLD COOL ROOM OLD AND NEW AT BV YARD AC PLANT AT CQAE AND INS VISWAKARMA INCLUDING PERIODICAL PREVENTIVE MAINT AT PACKAGE TYPE AC PLANT AT BV YARD INS VISWAKARMA AND CQAE UNDER AGE E M NO II OF GE U II VSKP
2021_MES_424511_1
8758
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Garrison Engineer Utility-II Visakhapatnam
CLASS D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-II
₹82,000
Yes
6 May 2021
4 Mar 2021
16 Apr 2021
4 Mar 2021
15 Apr 2021
3 Apr 2021
Amount
Manning and operation of AC plants of capacity 02 X 15 TR, Make : Voltas and water supply installations at CQAE including attending minor defects for smooth and trouble free operation and keeping an hourly record of temperatures (plant and inside rooms) by providing one skilled operator in General shift of 08 hours duration, including sundays and holidays, complete all as specified and directed by Engineer-in-Charge:- Shift timings:- 0900 Hrs to 1700 Hrs
Notes:- The quoted rate is deemed to be included for the following :- (a) One unit shall run at a time and one as standby in AC Plants and maintaining desired temparature. (b) Quoted rates are inclusive of consumble stores such as grease, lubricants, cotton waste, minor spares. (c) One emergency light, Digital Psychrometer at each AHU & AC rooms and necessary tools should be available in a tool box with operator for smooth functioning. (d) The quoted rate is deemed to be inclusive of maintenance of external water supply works of CQAE Area.
Note:- (1) To maintain the logsheet for AC plant, duty rooster, wages register and attendence registers. (2) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recommended by Engineer-in-Charge.
Manning and operation and maintenance to Cold Room Plant of Capacity 3 x 20000 BTUH (-16 degree to -20 degree centigrade) and cool room plant of capacity (3 x 10000 BTUH (plus 2 degree to plus 8 degree centigrade) and standby DG Set of capacity 125/75 KVA with connected items, at BV Yard, Visakhapatnam of Blue Star make, including attending minor defects for smooth and trouble free operation and keeping hourly record of plant and inside room temperatures complete, round the clock in 03 shifts of 08 hours each, by providing one skilled operator in each shift of 08 hours duration including sundays and holidays, complete all as directed by Engineer -in- Charge. Note:- Manning to item no 02 will Commence from 7 Nov 2021
Note for item No.1 to 2:- (i) Cleaning the sorroundings of the pumps and replacing gland packing, greasing periodicaly for smooth functioning of the pumps, Keeping daily record of pumpsets running hrs all as specified and directed by Engr-in-Charge is contractor's responsilbility. The rate quoted deemed to be inclusive of (a) Keeping neat and clean of complete installation area by grass cutting and removing the debris in & around premises upto 1.5 m from installation Bldg. (b) Keeping daily record of DG running hrs all as specified and directed by Engr-in-Charge . (c) Carrying out A check of DG set / DD Pump daily as per Manufacturer's manual. (d) Replacing of distilled water / battery electrolyte and charging of batteries as when required. (e) The installation will be handed over in operating staff on the commencement of contract through work order. (f) The operator shall ensure by trial run and be alert to run the DG Set within 5 minutes of supply failure in case of manual operation / failure of auto mains.
(g) Diesel shall be issued by department as and when required as directed by EIC. The quoted rate is deemed to be inclusive of loading, unloading and transporting of Diesel from store yard to work site. (h) Contractor shall have to intimate minimum 03 days in advance for issue of diesel under Sch ‘B’. (j) Filling of diesel in the fuel tank, regular checking of engine oil, battery electrolyte and radiator water level and rectifying minor defects such as Engine Air lock, tightening of loose bolts and nuts etc, which may develop during operation and relative parameters all as specified.
(1) To maintain the logsheet for AC plant, duty rooster, wages register and attendence registers. (2) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recommended by Engineer-in-Charge.
M&L chemical servicing of the air cooled indoor and outdoor condenser of 5.5 TR capacity AC plant by dismantling the sheet metal parts and including applying the organic compound of HCL with water for removing scale on the air cooled condenser, fins, tube area and flushing through forced method, till removal the complete scale deposit across the fins, tube and cleaning, fixing the sheet metal parts, fan blades etc, complete all as specified and directed by Engineer-in-Charge.
Taking down existing swing type PUF door and including supply and replacement of rubber gasket, PAD lock system, digital temperature indicator, hinges, necessary bolts, nuts etc, refix the door in same location after completion of repairs for cold / cool room complete all as specified and directed by Engineer-in-Charge.
Supply and replace Defrost Heater Coil suitable for 20000/10000 BTU Cold/cool room AC plant complete all as directed and specified.
Supply and replacement of Liquid line 5/8, 3/8 solenoid valve coil complete all as specified and directed by Engineer-in-Charge. Makes: INDIFOSS/ ACCO/ SPORLAN /DANFOSS
Supply and replacement of Liquid line drier unit of 5/8-1/2 flare type and leak testing the joints, and commissioning complete all as specified and directed by Engineer-in-Charge.
Supply replacement of Overload relay suitable to 5.5/7.5 TR oudoor unit motor starter complete all as specified and directed by Engineer-in-Charge.
M&L for carrying out leak test of cold room storage plant of capacity 20000 BTU Condenser with use of nitrogen gas, vaccumising complete system with double stage vaccum pump to below atmospheric pressure and rectifying the leakages, arresting the leakages and including charging gas, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
All as per Sl. Item No. 9 above but Compressor of capacity 20000 BTU.
All as per Sl. Item No. 9 above but Refrigerant valves, gauges, driers & safety valves and nuts of 20000 BTU Capacity.
All as per Sl. Item No. 9 above but 10000 BTU Capacity Condenser.of Cool Room
All as per Sl. Item No. 9 above but 10000 BTU Capacity Compressor.of Cool Room
All as per Sl. Item No. 9 above but Refrigerant valves, gauges, driers & safety valves and nuts of 10000 BTU of Cool Room
M&L for carrying out leak test of Ductable package/split AC plants of capacity up to 5.5 TR with use of nitrogen gas and vaccumising complete system with double stage vaccum pump to below atmospheric pressure, rectifying the leakages, arresting the leakages and including charging gas, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
All as per SL item No.15 above but 7.5/8.5 TR capacity. (Note for Sl item No 09 to 16:- (i) Necessary copper pipes, welding works are deemed to be included in the quoted rate. (ii) Refrigerant gas will be measured and paid separately.
Supply and replacement of PCB and Sensors for 10000 BTUH (1 x 10000) cold storage plant including all necessary control wiring complete all as directed and specified by Engineer-in Charge.
Supply and replacement of corded Remote hand set for 10000 BTUH(1 x 10000) cold storage plant including all necessary control wiring complete all as directed and specified by Engineer-in Charge.
Supply and replacement of Remote control Assembly for ductable AC plant of 5.5 TR complete all as specified and as directed.
Supply and replacement of Ductable wired remote controller for ductable AC plant of 5.5/7.5 TR complete all as specified and as directed.
Supply only refrigerant gas R-22 [Make: Floron/ Mafron]
Supply only compressor oil B 5.2/P-160 all as per specified and directed by EIC.
Supply only compressor oil. Make:Veedol/Sheethal N-68]
Supply only refrigerant gas R-410A/407 all as per specified and directed by EIC. [Make: Floron/ Mafron]
Supply only refrigerant gas R-134A all as per specified and directed by EIC. [Make: Floron/ Mafron]
Supply and replacement of grill of size 0.60 x 0.60 m. Make: Air Breeze/ Ravistar/ Air Master
M&L for disconnecting semisealed compressor motor of capacity 15 to 20 HP from the existing place (condenser pump set motor etc,) and including rewinding the motor with existing gauge copper conductor, varnishing and drying, replacement of worn-out bearings (DE& NDE), bushed connectors, terminal plate and re-fixing in original position, connecting cable through terminal block, preparation and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
All as per Sl. Item No 27 above but 5 HP.
M&L for taking down existing compressor cooling fan and including supply and replacement of bearing, varnishing the winding, greasing and refixing the same in existing position complete all as specified and directed by Engr-in-Charge.
All as Sl. Item No 29 above but fan for indoor unit. Complete all as specified and as directed.
Repair and maintenance of microprocessor unit of the ductable package / split units of capacity up to 7.5 TR and including renewal of defective unserviceable spare parts of PCB body, connected wiring, suitable connectors and other necessary accessories complete all as specified and directed by Engineer-in-Charge.
Disconnecting the filter bed from the AHU's of various sizes cleaning the air filters, removal of complete dirt deposited inside the cooling coil fins area by spary of scale removing agent and flushing out with fresh water till removal of complete dirt from the fins area and flushing out with air bolwer and refixing the same in existing position complete all as specified and directed by the Engineer-in-Charge.
M&L preparation and applying one coat of synthetic enamel paint to package type AC Plants of capacity (2 x 15 TR) and including out door units of AC Plant, control panel of AC plants complete all as specified directed by Engineer-in-Charge. NOTE: The quoted rate is deemed to be included for cleaning of approaches surrounding outdoor unit for carrying out painting of the plant.
All as per Sl. Item No. 33 above but capacity upto 1 x 5.5 TR.
M&L for disconnecting motor upto 2 HP capacity from the existing place (AHU / chiller / condenser unit / cooling tower motor etc,) and including rewinding the motor with existing gauge super enameled copper conductor, varnishing and drying, replacement of worn-out bearings (DE& NDE), bush connectors, terminal plate and refixing in original position, connecting cable through terminal block, preparation and painting exposed surfaces with one coat of synthetic enamel paint, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
All as per Sl. item 35 above but 5 to 7.5 HP capacity.
Supply and replacement of pilot solenoid valve coil (Make:Sporlon or equivalent of U-flow)
Material & Labour for Taking down old unserviceable compressor and alternation of MS base frame of compressor including alternation of suction and discharge, Insulation, anti-vibration pads, nuts, bolts, gaskets and misc items to match the existing base frame etc complete all as directed and specified by Engineer-in-Charge.
Supply and replacement of Semi Hermetic Reciprocating Compressor with Crank Case Heater & Ester Oil to cold/cool room Ac plant by debrazing the suction & discharge lines and including necessary welding / brazing with silver / copper brazing rods, copper pipe, sockets elbow, flushing out the complete system, pressure testing, vacummissing charging with refrigerant gas, testing and commissioning the package unit complete all as specified and directed by Engineer-in-Charge. Note:- Old unserviceable compressor deposited to MES Store. Make:- Danfoss of Blue Star Model No. RVAHOP-1014 or equilent in Voltas / Carrier
Supply and replacement of Expansion valve for 5.5/7.5 TR AC plant indoor/outdoor unit complete all as specified and as directed (Make:Sporlon or equivalent of U-flow)
Taking down carefully copper /alluminium point wiring (light ,fan, sockets light / power etc.) complete with fitting and fixtures such as any type of switches, ceiling rose, regulators, sockets ,light fitting, call bell, PVC /metallic holder, boxes, plate etc.all to be made credit to contractor and making good to disturbed surface of wall as per exisitng all as specified and directed.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated single core multi stranded copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses and PVC rectangular block with 3mm thick plastic laminated sheet cover as directed for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for the followings :-
One light point controlled by one way switch
One ceiling /exhaust fan point controlled by one switch
One sockets point on the same board with other swithches
All as above item above but using 2.5 Sqmm copper cable for 15 Amps sockets on independent board and using 2.5 Sqmm PVC insulated unsheathed single core muilti strandard copper conductor cable 1100 volts cable as earth wire connecting to as common earth dolly.
Supply and fixing switch 5 Amp piano 230 volts, one way flush type.
Supply and fixing switch socket combination 5 pin 6/15 Amp piano 230 volts, one way flush type.
S & F switch socket combination 3Pin 5 AMPs flush type complete all as specified and as directed
Supply & Fix ceiling rose surface bakelite 65 x 35 mm three terminals PVC/polycarbonate. complete all as specified andas directed.
Supply and Fixing in repairs Endura Linear Neo 20 Watt wall mounted LED batten, extruded Al heat sink, provided for efficient heat dissipation & integrated electronic driver including LED rod making electric connection from ceiling rose to tube light fitting complete all as directed in Engr in charge. Make - Havells, cat No. LHEWEBP5IN1W020 or equivalent to Phillips/Bajaj
Supply and fixing in repairs sheet metal enclouser disribution board for MCBs to be fixed 240 volts, SPN, 6 ways single door having 200 rated copper bus bar with neutral link , complete mounting on PVC board in suitable size minium one inch thick complete all as specified and directed.
Supply and fxing in repairs MCB , SPN , 40Amps, 10 KA , 240 volts complete.
Supply and fxing in repairs MCB , SP, 6 to 32 Amps, 10 KA , 240 volts complete.
Supply and fixing in repairs LED street/building security light, 60 W, 230 V AC outdoor type with high presure dia cast aluminium housing and heat resistance complete with driver, lamp bracket with impact and corrosion resistance including thermal management in multiple optics complete with IP 65/66 protection. Complete all as specified and directed. Make: Havells Cat part No: ENDURAPEARL PLUSSL60WLED757SASYTOPC
supply and fixing in repairs water level indicator, 36" dia as per IS and including numbering with radium stickering heavy duty float, counter weight heavy duty driving gear nylon wire fitted in all in GI housing, cutting the RCC slab and making good the slab, painting the exposed surface with two coats of synthetic enamel over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Dismantling the old unservicable installation "Glow sign" board and Design, fabricate, supply & install Glow sign board of size 1.80 x 1.00 x 0.20 metre of board made up of Plain steel sheet of 1.0 mm thick with M S medium grade Square tube supports of size 25mm with Bakelite flex (Transparent) type white and blue in colour by computerised stenciled letters in various clean white capital letters on blue/ other colour as directed in English/ Hindi with required numbers and Flourecent tube lights 4x40 watts (bajaj/Philips) fitting complete including necessary fitment, electrical wiring, MS angles/ Steel round bars, GI sheets, pipes clamps bolts & nuts all as directed by Engineer-in-charge.
Supply and replace power contactor of type MNX-25 complete all as directed.
Supply and replace power contactor of type MNX- 18 of L&T or equivalent complete all as directed.
Supply and replace Analog Timer , FM 1, quartz, 240VAC, 50/60 HZ make,L & T or its equivalent complete all as directed by the Engineer-in-Charge
Supply and fix in replacement of foamed polythene insulating pipe of any size for copper pipe of AC plant of any capacity complete all as specified and as directed.
M&L for replacement of wornout / unserviceable "V" belt for power transmission of following sizes :- Make: Fenner/Yule
Supply and replacement of scroll compressor 7.5/8.5 TR by debrazing the suction & discharge lines and including necessary welding / brazing with silver / copper brazing rods, copper pipe, sockets elbow, flushing out the complete system, pressure testing, vacummissing charging with refrigerant gas, testing and commissioning the package unit complete all as specified and directed by Engineer-in-Charge. Make: Voltas or equilent in Bluestar / Carrier
All as per Sl. item No. 60 above but 5.5 TR.
Supply and replacement of 1 3/8" discharge Brass GBC ball valve As per existing make available at site including necessary welding / brazing with silver / copper brazing rods, copper pipe, sockets elbow complete all as directed and specified .
All as per item Sl No. 62 above but of Indoor Unit capacitor starter.
Material & Labour for Opening of short circuited DIDW Centrifugal Blower motor 4000 cfm , cutting and removing the burnt stator winding coils complete and re-winding the same with super enamelled copper conductor wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, dryining complete and refixing the same complete all as specified and directed.
Material & Labour for Opening of short circuited DIDW Centrifugal Blower motor 1500 cfm , cutting and removing the burnt stator winding coils complete and re-winding the same with super enamelled copper conductor wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, dryining complete and refixing the same complete all as specified and directed.
S&F in repair MCCB 4 Pole, 415 V, fixed type, 63 to 125 Amps with breaking capacity 16 KA complete all as specified anddirected by Engr-in-charge.
S&F in repair MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 36 KA complete all as specified anddirected by Engr-in-charge.
S&F in repair MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA complete all as specified anddirected by Engr-in-charge.
S&F in repair MCCB 4 Pole, 415 V, 250 Amps with breaking capacity 36 KA complete all as specified anddirected by Engr-in-charge.
S&F in repair MCCB 4 Pole, 415 V, 320-350 Amps with breaking capacity 36 KA complete all as specified anddirected by Engr-in-charge.
Dismantling the unserviceable changeover switch and Supply and fix ON- LOAD change over switch advance neutral front handle with enclosure,sheet metal enclosure type 415 V 50 Hz, confirm of cap 200/250 Amps in the existing panel complete all as specified anddirected by Engr-in-charge.
M&L for Replacement of AHU filter of various sizes made of wire mesh for air filteration upto 15 microns complete all as specified anddirected by Engr-in-charge.
Supply and replacement of following spares for cold / cool AC plant, ductable package AC plant and ductable split AC plant complete all as specified directed by Engineer-in-Charge:-
Contactor MNX-32, 230 V 50 HZ
Auto defrosting contactor MNX-70, 230 V 50 HZ
Main switch rotary type 3 Pole 70 Amps including replacement of lugs, nuts and bolts. Make:-ABB/ L&T/C&S
Water flow switch 150 PSI, 15 Amps, 250 volts. Make: HONEYWELL/DANFOSS/ RANCO/JHONSON RAPID
Pressure gauge of capacity 0-150 PSI. Make: HONEYWELL/DANFOSS/ RANCO/ JHONSON RAPID
Pressure gauge of capacity 0-70 PSI. Make :- HONEYWELL/DANFOSS/ RANCO/ JHONSON RAPID
Water pressure gauge of capacity 0-7 Kg/cm². Make :- HONEYWELL/DANFOSS/ RANCO/JHONSON RAPID
Condenser pressure safety valve Make :- Indifoss/ Sporlon/Danfoss
Oil pressure cut out switch Make :- Indifoss/ Sporlon/Danfoss
HP/LP gas cut out switch Make :- Indifoss/ Sporlon/Danfoss
D.O.L Starter suitable upto 7.5 HP motor including replacing defective wiring with copper wire, lugs etc. including testing commissioning. Make:- L&T/SCHNEIDER/ SIEMENS.
HRC fuse link with carrier of 200A, 500VAC Make:- L&T/SCHNEIDER/ SIEMENS.
Fine filters of size 1'X1' Make Voltas
Fine filters of size 2'X1' Make Voltas
Supply and replace acid maintenace free battery 12 volts 180 AH, including 2 Nos. copper leads / connectors of suitable capacity/size/length complete all as specified and as directed.
GS ENGINEERS
SRIESWARI ENTERPRISES
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .