Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹20,850
Closing Date
8 Nov 2021, 5:00 pmClosed
Assistant Engineer(North)
Assistant Engineer(North) LSGD Engineering wing Thalassery Municipality
URGENT MAINTENANCE AND ADDITIONAL ELECTRICAL INSTALLATION AT TOWNHALL BUILDING AT THALASSERY MUNICIPALITY
2021_LSGD_449536_1
E6-14813-21
Open Tender
Electrical Works
Item Rate
90 days
Thalassery Municipality
Please refer Tender documents.
7 documents required · 7 mandatory
₹3,136
Yes
₹20,850
Yes
2 Feb 2023
30 Oct 2021
11 Nov 2021
30 Oct 2021
8 Nov 2021
30 Oct 2021
30 Oct 2021 - 8 Nov 2021
Amount
Part -I-Electrification
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FR PVC insulated stranded single core copper conductor cable 650V grade, including providing Switch Board main and continuous earthing with No. 14 SWG copper, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point.
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. Short point
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
Independent plug
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator.
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
Independent plug
supply,Conveyance, installation, testing and commissioning of ornamental wall light fittings robust &reliable LED Bulk head with IP 65 protection and IK 08 impact resistance(Philips make Model WT140W LED 7S CWPSU S1C-9405)or any other equivalent make directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
supply,Conveyance, installation, testing and commissioning of recess mounted 2" x 2" LED Panel light fittings 30 Watts(Philips make Model RC 380 B LED 30S 6500G4 L60 W 60 PSU OD OC)or any other equivalent make on ceiling including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.
Supply,Conveyance and fixing of recess mounting 10/15 Watts down light fittings(DN295BLED 10S-6500PSU WH Philips make or equlant make) complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc., as required.
Supply & installation of light fittings on TW round block<br>Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
Surface mounting decorative fluorescent tube light fitting complete with lamp with complete accessories duly wired up for use on 230 V AC .Surface mounting LED 20W LED Batten with out put 2000 lumen for use on 250V AC supply.
Supply,Conveyance, installation, testing and commissioning of LED foot light/ skirt light fittings of all types directly on wall including cutting necessary holes, giving connections with the extended original wiring, making good the damages, colour washing etc as required
Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer
Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
Supply and installation of suitable size rod type fan clamp as per IS 732 as required.
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extendedoriginal wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
Dismantling of Tube light fittings and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface,attending petty repairs and making good working condition reinstalling the same atb proposed position as required.
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required
Supply,Conveyance, installation , testing and commissioning of exhaust fans of 200 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230v single phase A/C in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan
Supply,Conveyance, installation , testing and commissioning of 450 mm sweep Tornado Wall fan with Metal leaf working on 230v single phase A/C fixing necessary anchor bolts / bolt and nuts etc.using attached clamp., as required including giving connections with the supplied wire along with the exhaust fan
Supply, Conveyance, Installation, Testing and Commissioning of 450mm or nearest size Sweep Air Circulating Wall Fan of Almonard or any other equivalent make of Havells, Bajaj etc. including giving connections as required.
Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required.
6 module metal box in recess(2x6A set of plug at Mini Conference hall)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch (set of plug and street light,gate light)
16 A SP 1 way switch with indicator
6A 3 pin shuttered socket
6 / 16 A combined socket
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required-20 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.50 sq mm 5 run (for set of plug circuit )
Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required
40 A four pole mini break isolator
63 A four pole mini break isolator
40 A, 4 pole, 30 mA RCCB
63 A, 4 pole, 30 mA RCCB
6 A to 32 A, 10 kA, SP MCB (C curve)
40 A, 10 kA, TP MCB (C curve)
Labour charges for unloading the materials,rent for baboo pole,conveyance chareges, making scaffolding and positioning for suitable position for dismantling the existing damaged light fittings and refixing the new light fittings and completing the work reloading, return the materials as required location
sajithvc
Bidder Name
Sajju T
sajithvc
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_641629.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .