Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC CB 4190 SREE CHITHRA NAGAR PANGODE THIRUMALA P O THIRUVANANTHAPURAM 695 006 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695006 | L1 | Accepted-AOC Lowest,Accepted by Tender committee | |
| 2 | L2₹6.4 L+₹56,893.55 (9.73%)Rejected-AOC | L2 | Rejected-AOC Second lowest |
Tender Value
₹5.8 L
EMD Value
₹8,800
Closing Date
15 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer Electrical HEED Harbour Eng
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram,TVPM
Harbour Engineering Department - Up gradation of outside lights at the Inspection Bungalow in Vizhinjam.
2021_HED_452065_1
42/HEED/2021-22/S
Open Tender
Electrical Works
Item Rate
30 days
VIZHINJAM
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,550
₹8,800
17 Jan 2022
8 Nov 2021
17 Nov 2021
8 Nov 2021
15 Nov 2021
8 Nov 2021
60 days
Amount
Fabricating, supplying, conveying, lifting and erecting Single arm tubular post of overall height of 7m using 6m 80mm and 1.5m 50mm Heavy G.I. Pipe having ISI mark and of approved quality as per the drawing, erected on a RCC 1:2:4 foundation in 1 No well steining of 0.25m depth and 0.75 m dia.at the bottom, 3 Nos well steining of 0.25m depth and 0.60 m dia. and a muffing of 0.45x0.45m with height 0.8 m. The post shall be erected on 4 numbers of 20mm dia GI foundation bolts of length 2.1m having 100mm long standard thread with a 12mm thick GI flange suitable for 80mm C class pipe at the bottom of the post and 80 D flange on the muffing with 4 nos of 20mm bolt holes and 3Nos of 20mm nuts per bolt. The bottom of the post shall be provided with suitable size stiffner pieces.The post is to be painted with two coats of best quality industrial epoxy paint over two coats of industrial epoxy primer . Muffing to be plastered using cement mortar 1:4, 12mm thick colour washing 2 coats using approved colour etc. complete.All GI pipe sections to be used for the fabrication of the post shall be of TATA/ZENITH/APOLLO make.All steel items shall be dip galvanised.
Supply of BIS approved LED Luminaire with system wattage of 60W, made up of pressure die cast Aluminium body and anti UV PC Protector with integrated lenses for increased pole spacing and uniform light distribution, IP66, IK 08, system efficacy of 110 lm/W, CCT 4000K, operating temp range up to 50 degree and designed for efficient thermal management, lumen maintenance L70@ 50000Hrs, Upward Light Output Ratio is 0% at zero degree inclination to avoid light pollution, suitable for side / vertical mounting up to 48mm diameter, Colour Rendering Index > 70, a driver efficiency > 85%, with internal surge protection of 4kV and Power factor > 0.95.Make: Keselec Cat Ref: Nice-O 60W NW LED or equivalent
Supply installation testing and commissioning of Keselec make Symmetrical LED based post top luminaire (SOFIA NW LED SYM 30W, IP66) on the existing Tubular post consisting of a high-pressure powder-coated die-cast aluminium housing, a canopy made of Plastamid and a UV-resistant highimpact polycarbonate protector. The luminaire emits a pleasant, glare-free light symmetric lighting. The complete luminaire is sealed to IP 66. The average power consumption shall be 50W The LED’s will be of neutral white. The protector shall be made of polycarbonate with IK 08 or above impact resistance. . The luminaires shall have an inbuilt surge protection.
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
Conveyance, installation, testing and commissioning of departmentally supplied flood light/ area light luminaire with lamp to a height upto 8m from ground level.
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 8 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and laying bare earthing copper conductor 8 SWG laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in Ordinary soil).
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply and fixing IP 65 outdoor installation CAPE 09 module( Model No Aki 09) 200x200x122mm Thermoplastic polycarbonate MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.
Supplying and fixing 40A, two pole, (single phase and neutral), 240 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 10 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 10 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) & 4.0mm (8 SWG) earth conductor including crimping etc. as required.
Wiring for light point / fan point/ exhaust fan/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required(Group B)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for LED Lamps including connection etc as required.
Supply and fixing 7/9 W LED lamp OSRAM / Philips or equivalent
Supplying and fixing following size / modules, Plastic boxes alongwith modular base & cover plate for modular switches on surface or in recess etc as required. 3 Module plastic box
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.4 X 4 sq. mm
Providing and fixing 50 mm dia nominal bore C class Heavy G.I. pipes with ISI mark complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
Providing and fixing 40mm nominal outerdia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall
Supply and fixing CAPE make TK 1818 -11 182x180x111 mm Polycarbonate outdoor opaque lid empty enclosure and accessories for Cable Junction Boxes such as Copper Terminal Set 4.0 sq.mm 5 Pole 1 No,Support for Terminal 1No , DIN rail for fixing MCB including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade upto 35 Sq.mm in the existing RCC/ HUME/ METAL pipe as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required.
Supply of 4 core 6 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
Supply of 3 core 2.5 sq mm PVC insulated and PVC sheathed submersible copper cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 C x 6 sq.mm
Supplying and making end termination nickel plated single compression brass cable gland for 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 kV grade as required. 4C x 2.5 sq.mm
Supply and fixing Elmex connector suitable for 4.0 sq.mm copper cable
Supply of 50/38mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II,
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Painting with epoxy paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Painting with 2 Coats of Industrial based Epoxy primer of approved brand and manufacture on steel galvanised iron/steel works (2 Coats)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Centering and shuttering including strutting, propping etc. and removal of form for : Roof
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metre.
Fabricating and supplying special clamping arrangement for fixing cable junctionbox on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm ,10mm or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxy based industrial primer of approved quality and two coats of best quaity synthetic enamel paint of approved colour as per drawing.
Welding Charges
gnarakkal brothers
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_645917.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .