| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC CA No. GE (AF)/ TVM/ 52 OF 2019 - 2020 | |
| 2 | L2₹9.7 L+₹24,077.20 (2.54%)Rejected-Finance HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹11.0 L+₹1.5 L (16.1%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted |
Tender Value
₹9.8 L
EMD Value
₹10,000
Closing Date
16 Mar 2020, 6:00 pmClosed
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
SPECIAL REPAIR FOR REPLACEMENT OF EXISTING IRON WOODEN WINDOWS AND DOORS WITH ALUMINIUM WINDOWS DOORS OF AIRMEN MESS P10 AT 17 FBSU AF STATION UNDER GE AFTRIVANDRUM
2020_MES_317842_1
GE AF TVM/ 8205
Open Tender
Civil Works
Item Rate
180 days
Trivandrum
As per NIT
7 documents required · 7 mandatory
₹500
GE AF Trivandrum
₹10,000
1 Apr 2020
23 Jan 2020
18 Mar 2020
23 Jan 2020
16 Mar 2020
6 Feb 2020
Amount
SCHEDULE 'A'
Demolition of cement concrete (Un reinforced) in ground floors n.exc 15cm thick (above or below ground level) complete
Demolition of cement concrete is reinfocement (reinfocement cut as equired to facilitate demolation )
Taking down chowkats or frames of any description exc 1.5 Sqm but not exc 4 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description exceeding 1 Sqm but not exc 2 Sqm each complete all as specified and directed
Taking down shutters of any description not exceeding 1 Sqm each complete all as specified and directed.
S & F powder coated aluminium anodised frames for doors, sliding windows ventilators with one or more rebates including anodised aluminium snap beading screws, joining cleat for fixing etc. complete all as specified.
S&F aluminium powder coated door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified
S&F aluminium powder coated sliding window and ventilator shutters, without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
M&L 12 mm thick prelaminated particle board exterior grade but prelaminated both sides with decorative choice laminations fixed with screws to aluminium door frame work.
S & F 5.0 mm thick sheet glass ordinary quality in square or rectangle exc 0.5 sqm in each pane fixed to alluminium window frame including necessary jointing cleat, glazing clip,rubber neoprene tacking anodised snapbeading screw complete all as specified and directed.
S & F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples
S&F aluminium power coated grill fixed with aluminium windows including frame all as specified and directed fixing etc. complete shall as specified.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
S&F Aluminium anodised barrel tower bolts 150mm of extruded section and fixed
S&F Butt hinges 125mm extruded brass with mild steel hinge pin bright polished and fixed, type B-21
S&F Aluminium alloy, anodised sliding door bolt 250mm with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed
S&F Mortice lock, vertical type, size 100mm
S &f Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor
s&F Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed
M & L cement concrete type C-1, 1:3:6 ( using 20mm graded stone aggregate), 50 mm thick , in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays
M&L for fixing APP based polymeric membrane minimum weighing 3kg/sqm and min 3mm thick reinforced with polyster non woven fabric (wt not less than 150gms/sqm) land on primed surface of evenly tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm by forced application over 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in roof padding in slop, finished surface even and smooth without using extra cement including picking, weeping cleaning and washing with down with water to remove dust etc from old concrete surface/floor and brushing cleaned surface with neat cement slurry with 3.0Kg of cement per sqm all as specified and directed .
S&F in repair 32 mm dia PVC waste pipe 90 cm long fexible type for Wash basin
S&F Bib taps, cast copper alloy,CP with crutch or butterfly handle, screwed down, screwed for iron pipe, 15mm bore of pipe brass ferrule fixed in repair.
S&F Pillar tap cast copper alloy with capstan head chromium plated fancy type, screwed down high pressure 15mm dia bore fixed in repair.
S&F in replacement; steel chromium plated round grating 100mm dia, fixed in position in cement mortar (1:3) complete all as specified.
M&L for Granite (of any type) as on kitchen plateform tiles 20mmthick machine cut, bedded andjointed with grey cement slurryand pointed with white cementwith admixture of pigment tomatch the shade of granite stoneincluding grinding and polishingcomplete
M&L TMT bars 10mm dia and over, cut to length, bent to shape reqd, incl cranking, bending spirally for hooping for columns, hooling ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L for RCC, 1:2:4, type B-1 (using 20mm graded stone aggregate) in slab supproted on walls, beam and columns in floor, roof etc
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs etc
S&F curtain rail ,20 mm dia anodised aluminium alloy ,cromium plated fixed with braket, incl taking down of old curtain rods, all as directed.
M&L for complete removale of existing old treatment and apply two coat of oil bound distemper to walls.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls directed by E-in-charge( Bore in 75mm)
M&L for preparation of old untreated wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of pink primer
M&L 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub floor under tiles, all as specified and directed.
M&L Screed bed or bedding layer or mortar 15mm layer of mortar 15mm thick for laying floor finishes 1:4 cement plaster
M&L Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L Non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L Glazed ceramic tiles coloured (300 x 200 x 7mm) thick for works on vertical surfaces on 10mm rendering surfacec Cement mortar 1:4 such as skirting/dados etc. set and jointed in neat cement slurry and pointed in coloured cement to match and directed by E-in-charge
Taking down cement plaster on brick or stone wall, including racking out joints, hacking for key scrubbing down with water etc.
M&L Rendering 15mm thick on fair faces of brick/concrete surfaces or in CM 1:4 finished even & smooth without using extra cement.
M&L Rendering 15mm thick on other than fair faces of brick/concrete or stone masonary surfaces in CM 1:6 finished even & smooth without using extra cement.
M&L rendering 5 mm thick in cement mortar 1:3 finished even and smooth without using extra cement on concrete surfaces complete all as specified and directed.
M&L for preparation of old treated surfaces of walls and applying two coats of distemper oil emulsiont over a coat of chalk whitening .
M&L for preparing new surfaces of walls and applying two coats of cement base paint over a coat of primer .
M&L Preparing of old plastered surface of ceiling and applying one coat of white wash on ceiling.
S&F in repair Cast iron nahani trap of 75mm dia of outlet with grating incl jointing to waste pipe fixed in cement concrete 1:2:4 type B-1.
Demolition of stone/brick masonary built in cement/cement lime mortar.
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 but except bricks.
M&L Providing, precast cement concrete in window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers weatherings, throating etc. and setting in mortar complete with joints to match
M&L Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides (30mm thick)
Taking up or down 15 mm bore GI steel tubing and connections complete all as specified and directed.
S&F 15 mm GI tube medium grade with all necessary fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x complete all as specified and directed.
S&F in repairs vitreous china wash down water closed pan(pedestal Pattern), white(excluding fixing bolts, flushing cistern and flush pipe) and including plastic seat cover complete all as specified and directed.
S&F 10 Ltrs PVC flushing cistern low level white with PVC out pipe,ball valve,float valve and handle including brackets complete all as specified and directed
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 485mm x 420mm bowl size 410mm x 3330mm x 160mm
M&L Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing.
M&L Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings.
S&F in repairs waste coupling suitable size for kitchen sink of CP (half or full threaded) complete all as specified and directed
Sub Total of Schedule 'A'
SCHEDULE OF CREDIT
Schedule of Credit (Minus) Rs. 8337.00 B/F from Ser page No.112. NOTE: Bidder shall insert credit amount as rate Rs.8337.00 in Green field under Col-5.
Sub Total of Schedule of Credit
DJ Group
Archana Transport
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .